StudentShare
Contact Us
Sign In / Sign Up for FREE
Search
Go to advanced search...

Facility design :Clean Room Reducing Level - Essay Example

Cite this document
Summary
The company has go five drugs type which are produced by the plants. The facilities capacity is 2x class 100 cleanrooms. However, the patent of the three drugs the company is producing will…
Download full paper File format: .doc, available for editing
GRAB THE BEST PAPER94% of users find it useful
Facility design :Clean Room Reducing Level
Read Text Preview

Extract of sample "Facility design :Clean Room Reducing Level"

Download file to see previous pages

There is intense pressure from the management to flatly reduce costs of this site or risk closure. The cost reduction option which was developed by the site team was to outsource three of the mature drugs from another BFT site located within the country and with lower labor rates. This was to be followed by downgrading both cleanrooms from class 100 to 1000. Furthermore, it was recommended that each cleanroom will only produce one new drug type at an increased rate that was not used before. Cleanroom is an environment that is completely controlled and where airborne particulates are regulated through an exchange of highly filtered air (1).

The air control is also regulated through minimization of activities which can literary generate particles. The room is used specifically for scientific research or production since the room has low levels of environmental pollutants (1). Class 100 cleanroom maintains less than 100 particles larger than 0.5 microns in each cubic foot of air space (1). It is also considered that class 100 is an equivalent of ISO class 5clean rooms (1). When it comes to the design difference between class 100 and 1000 clean rooms, it is evident that class 100 has unidirectional air flow system with average airflow velocity of 50-90 fpm (1).

The air change’s for class100 is counted to range between 300- 480 changes per hour (1). On the other hand, class 1000 has mixed type of air flow system with an average of 40-90 airflow velocity fpm and also possess between 150- 250 air changes per hour (1). The clean room class 1000 is ranked to an equivalent of ISO class 6 cleanroom. It is considered that the cleanroom capacity is wider to a maximum measurement of 600 square feet’s. In such capacity, the overall estimated level of particles harbored in the clean room is less than 1000 particles per cubic foot.

In addition to this, the particle control, the cleanroom has temperatures and

...Download file to see next pages Read More
Cite this document
  • APA
  • MLA
  • CHICAGO
(“Facility design :Clean Room Reducing Level Essay”, n.d.)
Facility design :Clean Room Reducing Level Essay. Retrieved from https://studentshare.org/miscellaneous/1639389-facility-design-clean-room-reducing-level
(Facility Design :Clean Room Reducing Level Essay)
Facility Design :Clean Room Reducing Level Essay. https://studentshare.org/miscellaneous/1639389-facility-design-clean-room-reducing-level.
“Facility Design :Clean Room Reducing Level Essay”, n.d. https://studentshare.org/miscellaneous/1639389-facility-design-clean-room-reducing-level.
  • Cited: 0 times

CHECK THESE SAMPLES OF Facility design :Clean Room Reducing Level

Designed House Cooling System

The essence of using reflective materials is to minimize the level of absorption thereby, minimizing the amount of heat to the housing unit....  • The roof will be narrow and tall to enhance air circulation and give room for air movements; it will also be extended to provide extra room for shading and less heat radiation thus, minimize heat from the sun entering the house.... A fan is an appliance used for ventilation of a room or any enclosed spaced....
6 Pages (1500 words) Research Paper

Material Failure and Embodied Energy

There are many reasons a structure can fail its basic ability to hold load (NEL, 2007) Many reasons as states in previously include basic design flaws, construction flaws, overloading, foundation failure, corrosion and excessive use of a moving body.... An example of it is the leaning tower of Pisa; the design flaw is the soft earth due to which one part of the building is sinking inside....
9 Pages (2250 words) Essay

Condensing Boilers

The bedrooms will not have as high of a demand for heat due to the fact that these rooms are smaller in size as well as one the upper level.... The room that will require the greatest amount of heat is the living room.... The living room is the largest room in the house and also has two windows which, in the wintertime, will be a major source for heat loss in that room.... The heating requirement for each room will vary based upon the size of the room, the location in the house, the number of windows, and the normal occupancy of the room....
6 Pages (1500 words) Assignment

Six Sigma: A Business Process Improvement Method

Six-Sigma is a management method focused on product and process quality, which was conceptualized by the Japanese executives of Motorola in the 1970s when foreign competition drove the US operations of the firm to the edge of bankruptcy.... The Quasar brand of TV sets was then the… In addressing the problem, the Japanese initially considered a quality improvement approach they had devised themselves called total quality management QM), but this was decided to be inappropriate for the problem at hand because its activities were exclusive to a firm's quality department and a few industrial engineers....
5 Pages (1250 words) Essay

A Detailed Inspection Report on Building Defect

m reception area designed into a bay reducing to 5.... 72m with gas fire set in original marble fireplace, deep skirting with same original ceiling features, the second reception room measuring about 5.... 84m, a slightly small room reception space as compared to the first.... Subsequently, there is a large cellarage composed of five individual rooms with rear breakfast room measuring 6.... 8m room the kitchen is fitted with two sink units, multi-paned sash bay window and fitted cupboards....
7 Pages (1750 words) Case Study

Means of Escape in Charm Building

m from ground level, inner rooms, flat roofs, and balconies.... This is towards enhancing escape means and reducing any fire risk.... nbsp;… The inner rooms of the Charm house will be taken as those rooms through which an individual uses another room to escape.... This arrangement can only be accepted when the inner room is a dressing room, bathroom or shower room, laundry or utility room, or kitchen....
7 Pages (1750 words) Term Paper

The Design Aspects of Typical Service Reservoir, Requirements to Ensure Watertight

… The paper "The design Aspects of Typical Service Reservoir, Requirements to Ensure Watertight" is a great example of a term paper on engineering and construction.... The paper "The design Aspects of Typical Service Reservoir, Requirements to Ensure Watertight" is a great example of a term paper on engineering and construction.... It is first important to consider the storage capacity required before making any major decisions about the design....
6 Pages (1500 words) Term Paper

Closed-Circuit Television Systems Design for Gold Facility

level one Requirements According to Cohen, Gattuso, and MacLennan-Brown (2009), before the installation of CCT systems, it is important to define the nature of the threat or risk facing the organization or premises.... As the paper "Closed-Circuit Television Systems design for Gold Facility" outlines, CCTV systems have become important tools in both private and public sectors.... The paper that follows will design CCTV systems for the gold storage facility taking into consideration the requirements and system specifications....
11 Pages (2750 words) Term Paper
sponsored ads
We use cookies to create the best experience for you. Keep on browsing if you are OK with that, or find out how to manage cookies.
Contact Us