Positron emission tomography - Essay Example

Cite this document
Summary
The analysis gives an easy to comprehend clarification on crucial features involved in PET instrumentation, current developments, and basic rules of radionuclide imaging. The study achieved these objectives by discussing methods of image rebuilding…
Download full paper File format: .doc, available for editing
GRAB THE BEST PAPER97.7% of users find it useful
Positron emission tomography
Read Text Preview

Extract of sample "Positron emission tomography"

Positron emission tomography The current diagnostic strategies adopt the use of technology to enhance efficiency, selectivity and prediction of results. For instance, Positron Emission Tomography (PET), which uses a noninvasive strategy, allows the rebuilding of cross-sectional images under examination. The rationale for the principle involves depiction of the biodistribution of substances used as PET tracers. Most tracers used in PET include isotopes of fluoride, oxygen, nitrogen, and carbon. These isotopes play a significant role in the investigation of the body. It is possible to carry out in vivo assessment of the parameters of biomolecular processes, metabolic pathways, and body perfusion and compare the finding between the disease and the normal state to draw valid clinical conclusions. The process involves the utilization of PET cameras. These cameras assess the quantitative measurement of the isotope concentration based on physical characteristics derived from the decay in positron. The analysis gives an easy to comprehend clarification on crucial features involved in PET instrumentation, current developments, and basic rules of radionuclide imaging. The study achieved these objectives by discussing methods of image rebuilding. The reconstruction took into account origin of signals, how image is processed and the likely problems associated with this approach. Besides, presentation of a summarized statistical method for image reconstruction was necessary for yielding authentic images. Isotopes with the tendency to radioactivity refer to atoms with an unstable nucleus. The inner core, which consists of the nucleus, has unbalanced energy. The dense package of neutron and proton makes the nucleus unstable. The lack of stability is the basis for the decomposition process. Therefore, through decomposition, the nuclei transform its configuration and components to a less strength and steady condition. This decomposition obeys the exponential law, which states ‘the number of decomposition per second is always equivalent to the amount of the undecayed nuclei available.' The law is also applicable to the rate of decay (activity). The decay depends on the half-life of the nuclide. Half-life is the duration/time that a nucleus takes to be halved. Positrons refer to the subatomic molecules that are equal in mass to an electron with characteristic of carrying a positive charge. When the positron decay (β+), its nuclei changes one of the core protons (p) to a neutron (n), while emitting positron (β+) to attain a positively charged nature referred to as neutrino (ν). Upon the release from the initial nucleus, the high positron moves across a few millimeters through the tissue until it attains thermalization, during the acquisition of thermal energy, the positrons arrive at thermal energies. They begin connecting with electrons either through annihilation that produce two 511 keV photons to take anti-parallel positrons frame or through development of the hydrogen that simulate orbiting couple also referred to as positronium. At its low energy levels, the positronium exists in two forms as ortho-positronium, which refers to the spinning of the positron and electron in a parallel manner. The other form called the para-positronium involves the anti-parallel spinning. However, Para-positronium decomposes through self- annihilation and creates two sets of 511 keV photons with anti-parallel spinning, while emission of three photons by the Ortho-positronium when it self-annihilates. The photons spread along the collinear paths by the degree of non-collinearity. These rely on the momentum generated by the positron and electron during annihilation process. Parting from collinearity is around a single degree or less and is not into considerations. The extent to which the positrons move before annihilating is a positron range. The significance of the scope relies on positron energy that differs in different isotopes. However, the extent of positron is much less than most scanner’s resolution, hence not an important source of error that can be ignored. The non-collinearity limit and the positron scope of the annihilation photons may result in the inherent positional miscalculations that are not reflected in a conventional single emission technique by the photon. The only two possibilities of interactions at 511 keV are photoelectric concentration and Compton scatter. In photoelectric absorption, an atom concentrates a photon and in the process, an electron is let out from one of its bound shells. The chance of photoelectric concentration enlarges faster with increasing atomic amount of the concentrator atom and reduces faster with enlarging photon energy. However, in water, the likelihood of photoelectric absorption decreases roughly by 3rd power of a photon energy that may be negligible at 511 keV. During an ordinary connection, a photon may connect with an outer shell electron and deflect to ensure some of its strength is lost. Most of the scattering photons encounter reduction of energy and a related transformation of direction that gets scattered out of the field of view making them unavailable for image resolution and formation. There is a term to refer the effects of the interactions, which is the attenuation. The amount of photons observation in a straight line from production place decreases exponentially when the increasing length of material traverses. The thickness of delicate parts of the body requires a reduction of the intensity of a beam used in projection by one-half is approximately 7 cm as in opposition to 3-4 cm for the x-rays. After approximately 14 cm to the delicate tissues, the 511 keV annihilation photon fluxes and has a potential for reduction by ¼ of the original intensity, in the abdomen, the photon also fluxes and reduces by 1/50 of its initial intensity. Therefore, attenuation is the most dominant factor in the creation of PET image because it checks on the picture quality, especially for well-built patients. The section that follows will assess some of the fundamental components in image reconstruction, data acquisition, PET radiopharmaceuticals, and PET scanners. Detectors are some of the crucial components of the PET cameras with their leading feature being the big scintillation crystals connected to many photo-multiplier tubes (PMTs). The ordinary scanners currently, scintillation detectors detect elements as part of their usage. They compare inorganic scintillation crystals that release observable or near the UV light after connecting with the incident high-energy (511 keV) photons to enable photo detectors detects and carry out the measurement of the scintillation photons. After photon interaction with the crystal, electrons move from the valence band to the conduction band. These electrons would shift to their valence band at impurities in the crystal that emits the light energy. However, since the pollutants exhibit metastable excited states, the light output is likely to decompose exponentially depending on the rate of the crystals. The primary crystal that has high density is likely to exhibit a larger fragment of incident photons scintillation. Besides, they possess high light output to enhance accuracy of position. These properties have fast risen time for accurate timing, and a short decay time so that high counting rates can be handled. The fabrication of block takes a method that seeks to control the amount of light collected by each PMT that differs uniquely relying on the crystal in which the scintillation took place. The integrals of these PMT outputs need decoding to yield the position of scintillation. The summation of integrated PMT outputs depends on the energy deposited by each of the crystal. The photon connects in the scintillating detector, light releasing take place and collection of a weighted sum of the PMT signal continues. Therefore, we can establish the moment within which an event in the small detectors occurred. Through this, it is possible to reduce the size of the detectors to enhance the spatial resolution that goes a mile to in limiting the number of PMTs needed. PMTs refer to vacuum tubes that contain a photocathode, which makes it possible for the arriving light photons to release electrons in a speedy and enhance amplification manner. The resultant electrical current ought to be proportional to the amount of original scintillation photons. The energy whose deposition in the scintillation crystal depends on the properties the PET photon, the rating of scintillators for PET can be because of their four features in highlight below Stopping power This refers to the inverse of the mean length moved by a photon before releasing energies in the crystals. This distance relies on the mass and operative atomic number (Z). A small travel gap is suitable because it leads to enhanced interaction with the 511 keV photons that result in a better efficiency for the detection of crystal fixed sizes. Decay constant The term explains how lengthy the scintillation flash proceeds in the crystal. Shorter decomposition constants are suitable because they permit the potential to count greater photon rates that have the potential to lowering the background rates. Good energy resolution It refers to a small ratio of the difference between the energy variances. When the difference is small, it signifies the presence of small fluctuations when measuring the energy. The property makes it possible to distinguish between the PET photons with Compton scattered (and lost power) before commencement of measurement. Such energy resolution relies on the light output as well as the intrinsic energy resolution inherent in each of the crystals. Light output This refers to the number of photons under production by each incident photon; the light produced need to be high to allow energy resolution with perfect spatial features. The initial tactic in an ET study is the creation of radiopharmaceuticals, which would be suitable for imaging the ailment under investigation. The ET imaging of a particular organ or illness starts with the creation of a robust radiopharmaceutical, which connects with the body in a way to producing essential images that give appropriate information. A radiopharmaceutical can be assessed in two parts: the tracer molecule, which connects with the body organs as well as the radioactive labels that permit the use of images. Clinical conditions like cardiology, neurology and oncology forms the basis for using positron emission tomography. The diagnosis is efficient because the shorter half-life of the positron used emits isotopes that require on-site cyclotron. The duration taken by administering the pharmaceutical molecule tagged with a radioisotope to the commencement of data collection relies on the objective of the imagery study as well as the state of the tracer used. Most studies will commence their data collection as soon as possible while others may take hours or even days after administering the radiotracer. Appropriate collection of data requires that the patient lie on the bed. The main reason measurement is possible is because the radioactive isotope emits gamma rays during the radioactive decay. The emissions are multi-directional on the patient’s body, proportional to the concentration of the molecule. For instance, a tumor imaged with 18 F-FDG will emit multiple gamma rays than surrounding tissues especially when the tumor has elevated metabolism for glucose. Detection and recording of the emitted gamma rays form the basis for the data collection by the imaging hardware. The location of the device should be around the patient to maximize data collection as it rotates the patient lying on the bed. The measurement by the gamma rays relies on both the directional and positional information to yield data for tallying into a histogram and communicate projections. A crucial part of PET imaging is the feature drawn from the positron annihilation; it is possible to visualize the two photons at the same time (coincidence state) from the detector ring. During the annihilation event that is synonymous with the radioactive tracer, it will be likely to locate somewhere on the line that connects the two photon-detection sections. However, several factors led to the photon detections unable to occur at the exact time. One of these relates to the annihilation occurring closer to one of the detector’s surface than it will to other. Such an attempt results in a measurable delay for the one photon given that the photon travels at the speed of light. The crucial temporal mismatches is the inestimable timing resolution that the detector uses, the timing in such a case is uncertain, which originates from the processing time of the PMT signals as well as the decay time of the crystal scintillation. Such effects give rise to using a coincidence time window (in the order of 6-10 ns). Detection of two-photon with a coincidence window is presumed to arise from a similar annihilation, which attributes to the line-of-response (LOR) in connecting the two detection points to enhance image sensitivity. These PET coincidence events are divided into four main groups namely the multiple, random, scattered, and true. The true coincidence takes place when detectors in coincidence get hold of both photons from an annihilation event. The photon neither undergoes formation of the interaction prior to the detection process nor allows event detection from the coincidence time window. On the other hand, the scattered coincidence refers to the potential of at least one of the detected photons undergoes scattering of Compton before detection. As the direction of the photon undergoes transformation during the Compton scattering, it is likely that the resultant events of coincidence are assigned to a wrong LOR. Besides, the scattered coincidences have valuable attributes to true coincidence distribution because it adds a background. The background has the potential to change slowly depending on the position, which decreases the contrast thereby overestimating the isotope concentrations. The other demerits are the addition of statistical noise to the signals produced. Detection of the quantities of scattered events depends on the attenuation volume inherent in the objected undergoing imagery as well as the camera geometry. Various coincidences take place when detection of more than two photons take place in different detectors aligned to the coincidence that resolves the time. In such a situation, it is difficult when establishing the LOR that guides the assignment hence high possibilities of event rejection. Besides, many coincidences are likely to cause event malposition. Several physical factors play a significant role in degrading the image qualities originating from the PET system, even though some have high chances of undergoing correction. True events are lost through attenuation, which happens through scattering and absorption, the likelihood that a certain photon having a particular energy undergoing interaction with the matter during the travelling is called linear attenuation coefficient (µ) of the substance under investigation. Random events mean that the two photons do not originate from a similar annihilation. The LOR gives the number of random coincidences, which correlates with the rate of a single event measured by the detector aligned to LOR. Squaring the field of view (FOV) increases the rate of random coincidence. Attenuation characteristic and volume of the object imaged affects the quantities of random coincidence under detection. Therefore, compensation is achieved by subtracting the estimated random coincidence acquired during delayed time-window. Read More
Cite this document
  • APA
  • MLA
  • CHICAGO
(“Positron emission tomography Essay Example | Topics and Well Written Essays - 2500 words”, n.d.)
Positron emission tomography Essay Example | Topics and Well Written Essays - 2500 words. Retrieved from https://studentshare.org/physics/1682820-positron-emission-tomography
(Positron Emission Tomography Essay Example | Topics and Well Written Essays - 2500 Words)
Positron Emission Tomography Essay Example | Topics and Well Written Essays - 2500 Words. https://studentshare.org/physics/1682820-positron-emission-tomography.
“Positron Emission Tomography Essay Example | Topics and Well Written Essays - 2500 Words”, n.d. https://studentshare.org/physics/1682820-positron-emission-tomography.
  • Cited: 0 times

CHECK THESE SAMPLES OF Positron emission tomography

Biology - Down's Syndrome

According to the National Institutes of Health, Down syndrome is “the most common single cause of human birth defects” (Kaneshiro, 2010).... Down syndrome is a trisomy of chromosome 21, which means that there are three chromosomes for pair 21 and so the person has a total of 47 chromosomes.... hellip; With its horrible mental and physical symptoms, Down syndrome is certainly a huge concern not only for medical professionals and for medical science but especially for the parents of those affected with this deadly and incurable genetic disorder....
9 Pages (2250 words) Term Paper

Crittercams and Positron Emission Tomography

This paper discusses the progress of science and technology in two such applications Crittercams and Positron emission tomography.... nother such technological tool is the Positron emission tomography (PET).... A minute quantity of positron emitting radioactive material is ingested into the body, in such a manner that it reaches an organ or area suspected of being diseased....
12 Pages (3000 words) Term Paper

Scientific journal (Nuclear Medicine)

The main issue presented in this research journal article involves the question of whether quantitative Positron emission tomography (PET) molecular imaging using specific labeled biomarkers can provide a reliable assessment of the levels of biomarker gene expression in tumor… The goal of this research is to use PET molecular imaging to provide a quantitative and selective assessment of the effects of targeted therapies on tumor biology and survival....
4 Pages (1000 words) Essay

PACS System Solution

here are various imaging instruments in which PACSs handle images are used such as ultrasound (US), magnetic resonance (MR), Positron emission tomography (PET), computed tomography (CT), endoscopy (ENDO), mammograms (MG), Digital radiography (DR), computed radiography (CR)ophthalmology....
2 Pages (500 words) Essay

Research paper on radiation

Ways in which radiation is employed in the medical imaging include but are not limited to projectional radiography, fluoroscopy, computed tomography, ultrasound, bone densitometry, medical resonance imaging, Positron emission tomography, and dual energy X-ray absorptiometry.... There are two basic types of radiation, namely the ionizing radiation and the nonionizing radiation....
2 Pages (500 words) Research Paper

Radioactive Material to Treat

This branch of medicine involves the use of trace radioactive… The most common type of radiation involved in nuclear medicine is the Positron emission tomography (PET).... he most common type of radiation involved in nuclear medicine is the Positron emission tomography (PET).... ositron emission tomography (PET) can examine body chemistry and is applied in medical tests as CT and MR scans.... ybrid scanning techniques employ X-ray computed tomography (CT) or magnetic resonance imaging (MRI)....
2 Pages (500 words) Essay

Neuroimaging Using the Magnetoencephalography

This summary is focused on relief from chronic pain and the use of the functional Magnetic Resonance Imaging technique in delineating the responses of pain before… Previously studies used magneto-electroencephalography and Positron emission tomography for the studies.... Previously studies used magneto-electroencephalography and Positron emission tomography for the studies.... Studies on neuro-imaging using the magneto-encephalography and Positron emission tomography had provided sufficient knowledge to prove that the pain matrix in the brain was the seat of a complex response to pain....
2 Pages (500 words) Article

Understanding Evidence-Based Practice Effect of PET vs. CT SCAN in Diagnosing Appendicitis

(2008); Selective Imaging Strategies for the Diagnosis of Appendicitis in Children (2004); FDG Positron emission tomography/Computed Tomography Studies of Wilm's Tumor (2010); and Computerized Tomography Utilization in Children with Appendicitis – Differences in Referring and Children's Hospitals (2011).... The essay aims to analyze the research articles "Can Computed tomography Scan be Performed Effectively in the Diagnosis of Acute Appendicitis without the Added Morbidity of Rectal Contrast?...
6 Pages (1500 words) Term Paper
sponsored ads
We use cookies to create the best experience for you. Keep on browsing if you are OK with that, or find out how to manage cookies.
Contact Us