Basic Tissue Processing for Routine Light Microscopy
Read TextPreview

Extract of sample "Basic Tissue Processing for Routine Light Microscopy"

Steps involved in Tissue Processing Tissue processing is a process by which tissues are taken from a body for diagnosis which is processed in the laboratory to produce microscopic tests and examined by the pathologists. There are different steps involved in tissue processing. Fixations are done to preserve the tissues and this should be carried out immediately after the removal of the tissues in order to prevent autolysis. There are 5 different groups of fixatives available which are Aldehydes, Mercurials, Alcohols, Oxidizing agents and Picrates. Formaldehyde is a good immonoperoxidase technique as the tissues are fixed by cross linkages formed by proteins and the cross links does not harm the protein structure and the standard solution is 10% neutral buffered formalin. Glutaraldehyde is also used for fixation and the standard solution is 2% buffered glutaraldehyde. This causes deformations in protein structure and penetrates very slowly but provides overall cytoplasmic and nuclear detail. Alcohols are usually not used for tissues as contain protein denaturants and cause brittleness. Oxidizing agents such as potassium permanganate is also not used frequently as they cross link proteins and cause extensive denaturation. There are number of factors which affect the fixation process such as buffering, penetration, temperature, volume, time interval and concentration of the solutions. Once the tissue has been fixed, they are processed into thin microscopic sections and embedded in paraffin. The technique of fixing tissues into paraffin is called tissue processing. There are two main steps in the processing which is dehydration and clearing. ‘Dehydration’ is a process of removing water from the tissues as wet fixed tissues cannot be directly infiltrated with paraffin. This is done by mixing alcohol (70%, 95% to 100%) with formalin. Once the tissues are dehydrated, the next step consists of removal of dehydrant with the substance that will be miscible with the paraffin. The common clearing agent used for this step is xylene. The next step involved is that the tissues are finally infiltrated with the embedding agent paraffin. ‘Infiltration’ is a process of impregnating the tissues with the embedding medium. This processed can be automated for large amount of tissues are processed. Automation consists of an instrument that moves through the tissues on a preset time. This activity can also be done with the help of tissue processor by manually picking the tissues out of the cassette and pouring paraffin over them. This ‘embedding’ process is very important as the tissues need to be aligned properly in the paraffin. Plastics require special reagents which are expensive for dehydration and clearing and for this reasons, most of embedding is done manually.
The next step involved is ‘sectioning’ which is done once the tissues are properly embedded. It is a process of cutting the tissues into sections such that they can be placed in the slide. This is usually done with the help of microtome which is a very sharp blade with advanced mechanism that can cut sections from 2 to 10 microns. The sections are cut and floated on a warm water bath that helps in removing wrinkles in the tissues and then they are picked up in the glass microscopic slide. These glass slides are warmed for 15 minutes to help the tissue section adhere to the slide. The next step is that the embedding process needs to be reversed so that the paraffin wax and water penetrate the tissue sections. The slides are ‘deparaffinized’ by cleaning the slides with xylenes to alcohol to water. Finally, the stained section is covered with a thin piece of plastic or glass which would prevent it from damaging and provide better quality. (Histotechniques)
Light Microscopy is the most common type used in the biological lab for tissue processing. A great advantage of light microscopy compared to acoustical microscopy is the fixation; sectioning and the staining techniques are optimized. Automated tissue processing has been achieved in the ‘technicon’ tissue processor but it does not allow the light microscopy tissues to be processed in a fully automated environment. The studies revealed that treating the fluids in light microscopy have to be recirculated. Also, processing takes place in open or closed chambers which are not suitable for holding pressure or vacuum conditions. Technicon tissue processor also involves movement and dipping motions of the tissue specimens into open chambers and these movements made during processing tends to damage the specimen’s. Light microscopy also does not handle tissue processing effectively in the sealed system. (Light Microscopy processing method)
This has lead to the invention of utilizing dual containers for treating liquids including paraffin which are drawn to a sealed processing chamber. The tissues are confined to the closed chamber and remain stationary during processing. Programmed sequence is set which helps in fixation, processing and cleaning solutions in the closed chamber. Under this automated mode of operation, the solution pump in and out and replacing the next solution takes place in the preselected time sequence. While this invention is primarily in terms of light microscopy processing, elimination of cleaning steps, de-energization of heated paraffin will help in automated staining apparatus. Earlier, the microscopes used suffered poor resolutions and the addition of another lens resolved this. The process of tagging created glowing molecules which simplified the way for the researchers to obtain information. In summary, series of improvement in light microscopy has lead to a new era in the field of biology. (Light Microscopy processing method)
Literary References
Histotechniques retrieved 25th Jan 2010 from website http://library.med.utah.edu/WebPath/HISTHTML/HISTOTCH/HISTOTCH.html
US patent 4001460- Light Microscopy processing method retrieved 29th Jan 2010 from website Read More
Cite this document
  • APA
  • MLA
  • CHICAGO
(“Basic Tissue Processing for Routine Light Microscopy Assignment”, n.d.)
Basic Tissue Processing for Routine Light Microscopy Assignment. Retrieved from https://studentshare.org/miscellaneous/1562225-basic-tissue-processing-for-routine-light-microscopy
(Basic Tissue Processing for Routine Light Microscopy Assignment)
Basic Tissue Processing for Routine Light Microscopy Assignment. https://studentshare.org/miscellaneous/1562225-basic-tissue-processing-for-routine-light-microscopy.
“Basic Tissue Processing for Routine Light Microscopy Assignment”, n.d. https://studentshare.org/miscellaneous/1562225-basic-tissue-processing-for-routine-light-microscopy.
  • Cited: 0 times
Comments (0)
Click to create a comment or rate a document

CHECK THESE SAMPLES OF Basic Tissue Processing for Routine Light Microscopy

Scanning Electron Microscopy

...differences in the images and explain these differences based on interaction volume changes with kV. The contribution from both SE and BSE must be taken into account. Image obtained at 2 kV This image is extremely light visibly reduced contrast. The fine circular granules and the horizontal dark lines are almost invisible. There is little distinction between the sample and the substrate. The image has very low resolution. This indicates that there are extremely less or no secondary electrons at all because of the low kV, i.e. 2kV. Lack of secondary electrons makes it difficult to view the surface topology and the contours of the specimen. The interaction volume is fairly low. Image obtained at 15kV Compared to the image...
15 Pages(3750 words)Coursework

Electron Microscopy

...are extremely light and the fine details are almost invisible. The raised circular grains and horizontal lines on substrate are also invisible. The lines are most prominent in the image obtained at 30 kV, and a little lesser in 15 kV. The fine circular grains are most prominent in the image obtained at 15 kV. The image obtained at 2 kV has very low contrast; the one at 30 kV has the highest contrast. The differences given above can be explained as follows: At 2 kV, there are very less secondary electrons and so, the topology of the image is almost invisible. At a higher kV, at 15 kV, there is better resolution and the topology is the clearest. This is because enough secondary electrons are released, making the raised...
21 Pages(5000 words)Coursework

Electron Microscopy

...Electron Microscopy la. Briefly describe how the main lens aberrations arise in electron microscopy. Electron microscopy is a technique in microscopy that offers higher magni-fication, higher resolution and greater depth of field in viewing objects. When the main lens aberrations arise in electron microscopy1 the high quality of resolution, light focusing to the point of object and depth of field is not achieved. Lens aberrations can exist in a form of chromatic aberrations. This exist when a range of wavelengths is instantly present in the light (for example in 'white' light) and occur because a single lens...
4 Pages(750 words)Coursework

Design of the Light Microscopy Facility

...space of 180M2. In this regard, all the equipments and microscopes will be arranged and fixed along the perimeter walls of the facility. The center space will be fixed with split benches where researchers will be able to carry out activities such as sample preparation and post acquisition image processing and analysis. To ensure flexibility and maximize the use of space, the corridors of the facility will have to be wider than 1800mm for easy movement of the equipment. The wide corridors will also be used as storage places when need arises. Finally Instead of partitioning the walls at the facility, I recommend that free standing shelving and cabinets shall be used to separate various compartments. Layout Diagram of the...
4 Pages(1000 words)Assignment

TISSUE PATHOLOGY

...?TISSUE PATHOLOGY DISSERTATION 0 of the disease 1 Introduction The body’s defenses against diseases are in place in the form of the immune system and this system, made up of several components and functions is supposed to ensure that as much as possible, the body is protected from any form of diseases or at worse, the body will be in a position to fight diseases that attack the body to ensure healing (Lichtenstein, Hanauer and Sandborn, 2009). These defensive mechanisms notwithstanding, it has not been always been the case that the body has been protected against diseases. There are many forms of diseases that attack the body in various ways and bring different effects. Once there is a failed system through the natural functioning... of the...
12 Pages(3000 words)Essay

Light Microscopy

...Swarnambika S Academia Research Light Microscopy October 9, 2007 Light Microscopy Microscopes that use visible light as a source of illumination are called light microscopes. Today’s light microscopes are compound microscopes. They provide greater magnification and are much easier to use. Compound microscopes have two lenses, an objective lens and an ocular lens, both of which are corrected lenses (several individual lenses bonded together) that compensate for the aberrations inherent in ordinary lenses (James & Tanke, 1991). Uncorrected aberrations produce images that are surrounded by colored rings (chromatic aberration), and not all parts of the field of observation are simultaneously in focus (spherical aberration). Parts... are used...
3 Pages(750 words)Essay

Routine Letter

...February 27, 2009 Desmond Bouchard Mardi Gras Novelties 2198 Orange Avenue Orlando, FL 32825 Dear Desmond: I cannot begin to tell you how excited I was to meet with you concerning the production that your company has to offer toward our project. Having planned several large scale marketing projects for our company, I have had wonderful opportunities to expand our associations through the participation of a diversity of businesses. I look forward to this being one of those opportunities as I am thrilled to tell you that your company is being awarded the contract. We have seen many clever and innovative presentations regarding this marketing venture, however, none of the other applicants showed the same understanding of our goals... 27, 2009...
2 Pages(500 words)Essay

Nervous Tissue

...Nervous2 Running Head: Nervous.... Topic: Nervous Tissue Order#: 350318 Topic: Nervous Tissue The function and responsibility of the nervous tissue is to sense stimuli and transmit signals to and from different parts. The basic unit of nervous tissue is neuron. Its structure is eminently suited to its functions within the nervous tissue. Its two important parts are (1) Cell Body, that has the neurons nucleus,...
2 Pages(500 words)Essay

ELECTRON MICROSCOPY ( TEM )

...ELECTRON MICROSCOPY Q1. a) Calculation of Mean Free Path Mean free path of a molecule is given by the following equation 1) Where, R = 8.2*10-2 (lit-atm)/(mol-K) = 8.2*10-5 (m3-atm)/(mol-K) is Gas Constant T = 300 K is absolute temperature of the air molecules in TEM column NA = 6.023*1023 molecules per mole is Avogadro’s Number d = 3*10-10 m is average molecule diameter of air molecules [2] P = 10-6 torr = 1.316*10-9 Atm is pressure in the TEM column Putting these values in equation (1) Mean free path () of air molecules in TEM column becomes Q1. b) This value is comparable to the column length of a TEM, which is approximately one meter or so. Q1. c) Yes Based on the answers in Q1. A) and Q1. B) vacuum...
3 Pages(750 words)Coursework

Atomic force microscopy

...Atomic Force Microscopy and Spin Coating Supervisor Study Program Contents Atomic Force Microscopy. 3 Contact method 4 Non-contact mode. 5 Tapping Mode 6 Spin Coating. 7 References. 9 Atomic Force Microscopy. An Atomic Force Microscopy is a device that can analyse the characteristics of a material at microscopic level and classify it. It enables one to view a material with good precision ranging between 100 micrometre and 1 micrometre. The instrument operates by allowing an exceptionally sharp and thin tip to get into contact with the surface or be in very close proximity to the surface whose characteristic is to be determined. The tip is a few microns in length and of small diameter, about 100A in diameter. This tip is attached... to the...
5 Pages(1250 words)Lab Report
sponsored ads
We use cookies to create the best experience for you. Keep on browsing if you are OK with that, or find out how to manage cookies.

Let us find you another Assignment on topic Basic Tissue Processing for Routine Light Microscopy for FREE!

Contact Us