StudentShare
Contact Us
Sign In / Sign Up for FREE
Search
Go to advanced search...
Free

Determination of PSA Serum Levels Using ELISA - Lab Report Example

Cite this document
Summary
Prostate-specific antigen (PSA) is a biomarker for prostate and its physiological function is to liquefy post-ejaculation semen (Herschman, Smith, Catalona, 1997). PSA is present in semen as well as in blood (serum). Apart from its physiological function, PSA has a diagnostic…
Download full paper File format: .doc, available for editing
GRAB THE BEST PAPER97.2% of users find it useful
Determination of PSA Serum Levels Using ELISA
Read Text Preview

Extract of sample "Determination of PSA Serum Levels Using ELISA"

The paper "Determination of PSA Serum Levels Using Enzyme-Linked Immunoabsorbent Assay" is a delightful example of a lab report on medical science. Pro specific antigen (PSA) is a biomarker for prostate and its physiological function is to liquefy post-ejaculation semen (Herschman, Smith, Catalona, 1997). PSA is present in semen as well as in blood (serum). Apart from its physiological function, PSA has a diagnostic value where elevated circulating levels are indicative of prostate abnormalities (Balk, Ko, and Bubley, 2003).

For instance, prostate cancer, prostatitis, and benign prostatic hyperplasia cause a marked increase in serum PSA levels (Velonas, Woo, Remedios, and Assinder, 2013). Quantitative analysis of PSA levels in serum is routinely done using Enzyme-Linked Immunoabsorbent assay (ELISA), an antibody-antigen technique (Lequin, 2005). In Elisa, specific antigens or antibodies or both are detected in a test sample using commercially prepared corresponding antigens and antibodies. In this experiment, PSA serum levels of three patients were determined in both diluted and undiluted state and the results compared.

Methodology A standard commercial Elisa kit was used for this assay; the plates were pre-coated with monoclonal antibodies against PSA (Acevedo, et al, 2002). Blood samples were obtained from the three patients using standard phlebotomy procedure and their respective serum labeled as patient A, patient B and patient C. For the second assay of diluted samples, an aliquot of the three serum samples were diluted fivefold using physiological saline. The samples were loaded on their respective plates (diluted and undiluted), incubated and washed as per the manufacturer’s instructions.

A secondary antibody conjugated to horseradish peroxidase (HRP) was added and incubated for 1 hour (Van Weemen, and Schuurs, 1971). Unbound antibodies were washed and the HRP substrate added for color development. The enzymatic reaction was stopped by adding a stop solution. The absorbance (OD) of the standard and the samples was read in a standard Elisa plate reader at 450 nm and recorded (Acevedo, et al, 2002). Results To improve the validity of each sample and the standard solution was tested in triplicates and the average calculated and used in the analysis.

Table 1 and 2 below show the respective absorbance (OD) of the standard and patient samples. The background absorbance was corrected by subtracting the absorbance OD from the average OD of the individual test run. The average OD values of the standard solution were used to plot a calibration curve that was used to calculate the individual PSA concentrations in each patient sample tested. The calibration curve is shown in figure 1 below. Figure 1 Standard Curve used to determine the final PSA concentration (0-1000ug/ml).

Values represent absorbance reading at 450nm It is important to note that the unexpected peak at point 50ug/ml may have been caused by a technical error during the assay run. However, it is insignificant in that it does not affect the interpretation of patient sample tests. From the calibration curve shown in figure 1 above the actual PSA concentration for each patient, the sample was calculated and tabulated as shown in table 3 below. The results show the discrepancy between diluted and undiluted samples of the same patient.

There are a number of reasons that can explain this observation and are discussed in the following section of the report. Discussion The experiment was successful in using the ELISA sandwich technique in estimating the PSA serum concentrations of patient samples. However, interpreting these results is not recommended due to questionable validity. Validity and reliability are important in any diagnostic and even scientific test as it boosts the confidence of the results obtained (Acevedo, et al, 2002).

There is a couple of techniques used to improve the reliability of laboratory tests results such as the user controls, SOPs, and testing in duplicates or triplicates(Acevedo, et al, 2002). Technical errors such as pipetting and mixing errors are common culprits in many cases of unexpected results. The peak at the standard concentration of 50ug/ml is a good example. A reliable test should give consistent results even when the sample is diluted and the correct adjustment made. The variation seen in the results of this experiment may be explained by the introduction of an error during the test procedure.

The error that caused the unexpected variation in the calibration curve may also have contributed to the difference seen between diluted and undiluted samples. Other possible sources of error include faults in assay machines and use of wrong samples. The use of SOPS and quality assurance programs are fundamental in reducing and minimizing chances of error (Acevedo, et al, 2002).

Read More
Cite this document
  • APA
  • MLA
  • CHICAGO
(Determination of PSA Serum Levels Using ELISA Lab Report, n.d.)
Determination of PSA Serum Levels Using ELISA Lab Report. https://studentshare.org/medical-science/1816047-immunology
(Determination of PSA Serum Levels Using ELISA Lab Report)
Determination of PSA Serum Levels Using ELISA Lab Report. https://studentshare.org/medical-science/1816047-immunology.
“Determination of PSA Serum Levels Using ELISA Lab Report”. https://studentshare.org/medical-science/1816047-immunology.
  • Cited: 0 times

CHECK THESE SAMPLES OF Determination of PSA Serum Levels Using ELISA

Elise Smart's Problem

This paper presents Elise Smart's problem which is that she must decide what performance assessment to give to one of her employee who has, uncharacteristically, failed to meet one of her key objectives for the year.... nbsp;The situation is difficult for Smart.... hellip; According to the discussion, Elise Smart's Problem, the employee has previously received excellent appraisals, including a recent one by the vice president....
4 Pages (1000 words) Essay

Determination of Serum Lactic Dehydrogenase Activity

In order to replenish the energy supply, (NAD) in the presence of low levels of oxygen, LDH converts pyruvate to lactate.... We can do an electrophoresis with a normal person's serum and note the intensities of the color produced.... Then we can do an electrophoresis with a patient's serum and note the intensities of color produced....
3 Pages (750 words) Essay

Tower of Pisa Issues

The essay "Tower of Pisa" deals with the leaning tower of Pisa which is constructed to show the wealth of the city of Pisa to the world.... Nevertheless, The people of Pisa are good sailors and they manage to conquer many lands including; Jerusalem, Norway, and Morocco among others.... nbsp;… As suggested by Mitchel (2001), the leaning tower of Pisa is located in Campo dei Miracoli commonly known as 'field of miracle' in Italy, behind the cathedral....
6 Pages (1500 words) Essay

Techniques for the Biomedical Sciences

Chorionic Gonadotrophin hormone is also useful in man in the determination of cancer of the testicles.... The essay "Techniques for the Biomedical Sciences" presents elisa tests which have been widely used in the separation of antibodies especially by the use of blood serum.... hellip; elisa was developed in 1970 as a replacement for radioimmunoassay.... elisa is a biochemistry assay that is wet in nature used in the detection of substance usually an antigen....
4 Pages (1000 words) Essay

Ella Minnow Pea

The following paper 'Ella Minnow Pea' focuses on the context of a book where the quote's an example of the appliance to silly despotic rules, which not allows using particular letters on the island of Nollop.... Days of a week now sound funny and invalid, unacceptable and childish....
1 Pages (250 words) Literature review

The Effect of Bank Provision for Loan Losses

Keynes in his analysis of income determination of a country hypothesised that income is subject to fluctuation and is characterised by boom and busts.... Greenawalt and Sinkey wonder why managers would want to smooth accounting incomes using loan loss provisions....
2 Pages (500 words) Essay

Major Dilemmas of ERISA

The essay "ERISA Law" discusses the prerequisites, adoption, and implementation of the ERISA Law.... nbsp;ERISA stands for the Employee Retirement Income Security Act of 1974.... nbsp;It is the federal statutory law that governs all benefit plans of employees as well as employees' welfare benefit plans of private employment....
8 Pages (2000 words) Essay

Colorimetric Determination of Salicylate in Urine

This lab report "Colorimetric determination of Salicylate in Urine" aims at learning the steps followed in the determination of salicylate in Urine, determining the presence of salicylate in urine and determining the concentration of salicylate in standard solutions and urine.... onsidering the fact that a large number of people are consuming the drug either knowingly or unknowingly, the determination of salicylate in the human body is paramount to facilitate proper prescription treatments....
5 Pages (1250 words) Lab Report
sponsored ads
We use cookies to create the best experience for you. Keep on browsing if you are OK with that, or find out how to manage cookies.
Contact Us