Positron Emission Tomography - Article Example

Cite this document
Summary
This paper 'Positron Emission Tomography' tells that Positron emission tomography, allows the rebuilding of cross-sectional images of the human body depicting the biodistribution of PET tracer substances.  A more significant portion of physiological PET tracing implications that broadly involve isotopes of carbon etc…
Download full paper File format: .doc, available for editing
GRAB THE BEST PAPER91.5% of users find it useful
Positron Emission Tomography
Read Text Preview

Extract of sample "Positron Emission Tomography"

Positron emission tomography Positron emission tomography (PET) being a noninvasive diagnostictechnique, it allows rebuilding of cross-sectional images of human body depicting bio distribution of PET tracer substances. A greater portion of physiological PET tracing substances that greatly involve isotopes of carbon, nitrogen, oxygen and fluorine is accessible and permits vivo investigation of body part perfusion, metabolic pathways and bio molecular processes where there is a normal and diseased state. PET cameras make great use of real features of positron putrefy to extract quantitative computation of tracer absorptions. The analysis gives easy clarification of crucial features involving basic rules of radionuclide imaging, PET instrumentation and current developments. Image rebuilding ways having a beginning in signal and image processing is in discussion below. In addition, potential limitations of the methods in discussion are in highlight as well as analysis of statistical picture recreation ways that have ability to bring about a better picture standard Radioactive isotopes refer to iota whose interior core and nucleus is not steady that is, they have a lot of buoyancy. Nuclei consist of heavily loaded disposition of protons and neutrons. Through decomposition, nuclei transform their configuration and features to contain less strength and steady condition. Decomposition procedure obey an exponential law that is, the number of decomposition per second is always equivalent to the amount of the un-decayed nuclei available. However, the same is true for the rate of decay or activity that is determined by half-life of the particular nuclide- the time it takes for half of the original nuclei to decay. Positrons refer to subatomic speck equal in mass to an electron but carry a positive charge. In positron decay (β+), nuclei adopt one of its core protons (p) into a neutron (n) resulting to the release of positron (β+), usually a positively charged electron, and a neutrino (β+). After the release from the actual nucleus, the strong positron move across a few millimeters through the tissue until it endures thermalization. When the positrons arrive at thermal energies, they begin connecting with electrons either by annihilation, which produces two 511 keV photons that are anti-parallel in the positronís frame, or through development of a hydrogen-like orbiting couple known as positronium. At its foundation condition, positronium has two types’ of- ortho-positronium, where the spins of the electron and positron are parallel, and para-positronium, where the spins are anti-parallel. However, Para-positronium decomposes again through self- annihilation those end up in creation of two anti-parallel 511 keV photons. Ortho-positronium self-annihilates by the emission of three photons. The photons spread along nearly collinear paths, with the degree of noncollinearity relying on the momentum of the positron and electron when they annihilated. Parting from collinearity is around a single degree or less and is not into considerations. The extent to which the positrons move before annihilating is positron range. The significance of the scope relies on positron energy, which differs in different isotopes. However, positron scope is much smaller than the resolution of most scanners, so it is not a serious source of error and is usually no tin consideration. The limit positron scope and the non-collinearity of the annihilation photons give rise to an inherent positional in absolute not present in the conventional single photon emission techniques. However, other features of PET are in discussion below more than offset this disadvantage. The only two possibilities of interactions at 511 keV are photoelectric concentration and Compton scatter. In photoelectric absorption, an atom concentrates a photon and in the process, an electron is let out from one of its bound shells. The chance of photoelectric concentration enlarges faster with increasing atomic amount of the concentrator atom, and reduces faster with enlarging photon energy. However, in water, the probability of photoelectric absorption decreases with roughly the 3rd power of the photon energy and is negligible at 511 keV. During an ordinary connection, the photon connects with an outer shell electron such that its way is in deflection and some of its strength is lost. Most of the scattering photons encounter reduction of energy and a related transformation of direction are scattered out of the field of view and so are unavailable for image formation. There is a term to refer the effects of the interactions, which is attenuation. The amount of photons that are in observation at straight line from production place decreases exponentially with increasing length of material traversed. The thickness of smooth matter required to reduce the intensity of a beam by one half is approximately 7 cm as in opposition to 3-4 cm for x-rays. After approximately 14 cm of smooth matter the 511 keV annihilation photon flux can be in reduction to ¼ of its original intensity, and through the abdomen, the photon flux can be reduced to 1/50 of its original intensity. Thus, attenuation is often the dominant factor in PET image quality, especially for thicker patients. Below are the basic components in PET scanners, PET radiopharmaceuticals, data acquisition, and image reconstruction. Detectors are some of the crucial components of the PET cameras with their leading feature being the big scintillation crystals connected to a lot of photo-multiplier tubes (PMTs). The ordinary scanners currently, scintillation detectors detect elements as part of their usage. They connect inorganic scintillation crystals that release observable or near ultraviolet light after connection with an incident high-energy (511 keV) photon to photo detectors that detect and measure the scintillation photons. After photon interaction in the crystal, electrons move from the valence band to the conduction band. These electrons then return to the valence band at impurities in the crystal emitting light in the process. However, since the pollutants usually have metastable excited states, the light output decomposes exponentially at a rate features of the crystal. The basic crystal has high density so that; a large fragment of incident photons scintillate, high light output for positioning accuracy, fast rise time for accurate timing, and a short decay time so that high counting rates can be handled. The block is in fabrication in a way that the amount of light in collection by each PMT differs uniquely relying on the crystal in which the scintillation occurred. Hence, integrals of the PMT outputs can be decoded to yield the position of scintillation. The summation of integrated PMT outputs is proportional to the energy deposited in the crystal. When photon connects in the scintillating detector, light releasing take place and collection of a weighted sum of the PMT signal take place. Therefore, we can establish the moment within which an event in the small detectors occurred. Through this, the size of the detectors can be reduced to better spatial resolution which in turn there will be limiting of the number of PMTs that are in need PMTs is vacuum tubes with a photo cathode where the arriving light photons release electrons that are in speed and amplification. The end results of electrical current is proportional to amount of original scintillation photons and therefore to the energy deposited in the scintillation crystal by the PET photon. The rating of scintillators for PET can be because of their four features in highlight below Stopping power This refers to the inverse of the sum of the gap moved by photons before they release energy in the crystal .This distance relies on mass and operative atomic number (Z). A small travel gap is suitable because it will lead to increased interactions with the 511 keV photons and a better efficiency for detecting them in crystal of fixed size. Decay constant This explains how lengthy the scintillation flash proceeds in the crystal. Shorter decomposition constants are suitable because they permit counting greater photon rates and lower background rates. Good energy resolution That is, a small ratio of strength difference over energy means that there are only small inconsistencies in the energy measurements. This gives a means to distinguish against PET photons that have Compton scattered (and lost energy) before being measured. The energy resolution relies on the light output and the intrinsic energy resolution of the crystal. Light output This refers to the number of photons in production by each incident photon of which, it should be high to allow the perfect spatial and energy resolution. The initial tactic in an ET study is building of a radiopharmaceutical that is suitable for imaging the disease in question. ET imaging of a specific organ or disease begins with development of a radiopharmaceutical that will connect with the body in a way that produces communicative image. A radiopharmaceutical involves of two parts: the tracer compound that connects with the body and the radioactive label that permits us to image it. A crucial importance of PET imaging is that due to the positron annihilation we anticipate to see two photons at the same time (coincidence) in the detector ring. The annihilation event, i.e. the radioactive tracer, will then be located somewhere on the line connecting the two photon-detection points. However, several factors led to the photon detections not occurring at the exact time. The annihilation may occur closer to one detectors surface than the other that will result in a slight but measurable delay of one photon, where the photons travel at the speed of light. The crucial temporal mismatches is the infinite timing resolution of the detector that is, its timing uncertainty that arises from decay time of the scintillation in the crystal and the process time of the PMT signals. These effects lead to the use of a coincidence time window (order of 6-10 ns). Coincidence events in PET fall into 4 categories: true, scattered, random and multiple. True coincidence takes place when detectors in coincidence get hold of both photons from an annihilation event. Photon neither undergoes any form of interaction prior to detection nor is no other event detected within the coincidence time-window. On the other hand, scattered coincidence is one and in which at least one of the detected photons has undergone at least one Compton scattering event prior to detection. As the direction of photon undergoes a change during the Compton scattering process, it is likely that the resulting coincidence event will be assignment to the wrong LOR. Scattered coincidences add a background to the true coincidence distribution, which changes slowly with position, decreasing contrast and causing the isotope concentrations to be an over estimate. They also add statistical noise to the signal. The number of scattered events detected depends on the volume and attenuation features of the object being imaged, and on the geometry of the camera. Various coincidences take place when more than two photons detection take place in various detectors within the coincidence resolving time. In this situation, it is not possible to establish the LOR to which the event should be assigned and the event is rejected. However, dispositioning can be due to various coincidences. The quality of images in production by PET degrades through several physical factors of which some of the factors can undergo correction. Attenuation is the loss of actual happenings due to scattering and absorption. The total probability that a photon of a specific energy will undergo some type of connection with anything that occupies space and has mass when travelling unit distance through a particular substance is linear attenuation coefficient (µ) of that substance. The number of random coincidences detected also depends on the volume and attenuation features of the object image and on the geometry of the camera. Compensation for random coincidences is at performance by subtracting an estimate of the random coincidences under acquisition in a delay-timing window Read More
Cite this document
  • APA
  • MLA
  • CHICAGO
(Positron Emission Tomography Article Example | Topics and Well Written Essays - 1500 words, n.d.)
Positron Emission Tomography Article Example | Topics and Well Written Essays - 1500 words. https://studentshare.org/physics/1864574-positron-emission-tomography
(Positron Emission Tomography Article Example | Topics and Well Written Essays - 1500 Words)
Positron Emission Tomography Article Example | Topics and Well Written Essays - 1500 Words. https://studentshare.org/physics/1864574-positron-emission-tomography.
“Positron Emission Tomography Article Example | Topics and Well Written Essays - 1500 Words”. https://studentshare.org/physics/1864574-positron-emission-tomography.
  • Cited: 0 times

CHECK THESE SAMPLES OF Positron Emission Tomography

Article summary of Roschach

The findings of over 125 meta-analysis and 800 multimethod assessment studies have shown that psychological assessment instruments such as the Rorschach perform as effectively as any instrument used in the entire health services industry such as “electrocardiograms, mammography, magnetic resonance imaging (MRI), dental radiographs, Papanicolaou (Pap) smears, Positron Emission Tomography (PET) scans, and serum cholesterol level testing”....
1 Pages (250 words) Essay

Antimatter Research: Bane or Boon

Positron Emission Tomography, PET, for example relies on antimatter.... (The History of antimatter, 2001) In 1932 Carl Anderson, a young professor at the California Institute of Technology, while studying showers of cosmic particles in a cloud chamber discovered antielectron, He called the antielectron a "positron", for its positive charge....
4 Pages (1000 words) Essay

Use of Landmarks in Skull of Dog (Canis familiaris) for Neuronavigation

This spatial accuracy afforded by functional imaging systems such as, primarily, magnetoencephalography (MEG), functional magnetic resonance imaging (fMRI) and Positron Emission Tomography (PET), when incorporated within the neuronavigation process, allows precise surgery near eloquent areas of the brain with minimum morbidity (Ganslandt, O....
5 Pages (1250 words) Article

Plexiform neurofibromatosis

Neurocutaneous disorders are diseases that involve nervous system, skin, and retina and other ectodermal tissues.... They are congenital.... Migration of neural cells to brain and melanoblasts to the skin from the neural crest occurs between 3 to 6 months of intrauterine life.... hellip; Neurofibromatosis is an autosomal dominant neurogenetic disorder....
4 Pages (1000 words) Essay

SEO content for a web site selling custom trailers

Customized mobile medical exam trailer must have these basic health services:X-ray sectionGeneral Checkup and Mobile Treatment SectionMobile Laboratory for Blood, Urine and Pap Smear AnalysisDisease detection and treatment sectionUltrasound, Mammography, and Radiography (X-rays), and EKG Unit Positron Emission Tomography (PET) / Computed Tomography (CT) Scans Unit Magnetic Resonance Imaging (MRI) SectionMobile Ophthalmology Clinic Dental Care Section Others as to clients' specifications Medical Imaging equipments are expensive to acquire and install....
2 Pages (500 words) Essay

PACS System Solution

here are various imaging instruments in which PACSs handle images are used such as ultrasound (US), magnetic resonance (MR), Positron Emission Tomography (PET), computed tomography (CT), endoscopy (ENDO), mammograms (MG), Digital radiography (DR), computed radiography (CR)ophthalmology....
2 Pages (500 words) Essay

Application of Psychology in Life

In cognitive neuroscience, an individual is able to get motivation by focusing on invasive components of functional neuroscience such as Positron Emission Tomography and diffusion tensor imaging which provides a broad spectrum of basic scientific understanding of diverse matters regarding behavior, brain, and cognition (77)....
2 Pages (500 words) Essay

Buying Behavior: A Need or a Disorder

This essay "Buying Behavior: A Need or a Disorder" discusses codes in states such as the State of California that indicate that lunatics, idiots, and insane people are not capable of registering their actions and therefore are not responsible for their actions.... hellip; Many diseases seem to overlap in the DSM model; in OCD, one may either count or not count kleptomania as they have many similarities as well as many differences....
5 Pages (1250 words) Essay
sponsored ads
We use cookies to create the best experience for you. Keep on browsing if you are OK with that, or find out how to manage cookies.
Contact Us