The use of an induction motor as a generator requires a magnetizing current for excitation and a prime mover to maintain the rotor speed above the synchronous speed. In a self-excited induction generator the excitation is provided by the capacitor connected across the stator…
Download full paper File format: .doc, available for editing
GRAB THE BEST PAPER96.3% of users find it useful
Theory of operation single phase induction generator at load state ,
Read Text Preview

Extract of sample "Theory of operation single phase induction generator at load state ,"

2. Theory of single phase generators The use of an induction motor as a generator requires a magnetizing current for excitation and a prime mover to maintain the rotor speed above the synchronous speed. In a self-excited induction generator the excitation is provided by the capacitor connected across the stator winding as shown in Fig 1. Fig1 – Capacitor connected induction generator Before a generator can be applied to supply power to a specific electrical load, it is important to understand the voltage and frequency of power that will be generated.

This is discussed in the sections below. 2.1 Factors that determine the generator voltage and frequency a) In the single phase induction generator, the excitation voltage and frequency vary depending on the rotor speed, the values of the capacitance and the winding inductance and the load current. For any value of capacitance, there is a minimum rotor speed at which self-excitation would occur [1]. It is difficult to measure the self inductance of the generator winding directly.

An approximation can be made by driving the rotor at synchronous speed and measuring the stator voltage and current. At the rotor synchronous speed, no current is induced in the rotor and it is a virtual open circuit. The measured impedance (V/I) can be approximated for the winding self-inductance. The resonant frequency is given by ω0 = 1/ √ LC From the above relationship, the value of the capacitance required for resonance at 50 Hz is calculated by C = 1/ ω02 L From the above equations, it is clear that the self-inductance of the winding would vary with the voltage induced in the winding.

The variation of magnetizing inductance with voltage for a specific induction generator is shown in Fig 2. Fig 2- Variation of self-inductance with voltage The inductance increases from (A) to (E) on the curve with an increase in voltage and then falls from (E) to (C) as the machine begins to saturate. b) For a given speed of the rotor, the voltage generated in the winding would vary with the value of the connected parallel capacitor. The relationship between the terminal voltage and the value of the capacitor for a specific induction generator is shown in Fig 3.

Fig 3 – Variation of terminal voltage with value of capacitance at constant speed One requirement in any electrical generator is for the terminal voltage to remain constant when the connected load varies. Most electrical loads operate satisfactorily only in a narrow range around their rated voltage. The value of capacitance needed to maintain constant terminal voltage at a given rotor speed is shown in Fig 4 for a specific induction generator. The graph shows that the variation is linear.

Fig 4- Capacitance value to maintain constant terminal voltage with change in load In addition to the constant voltage, an alternating current generator also needs to supply power at a constant frequency. For the single phase self-excited generator, we know from induction motor theory that as the load current changes, the slip between the rotor and the stator would vary and cause the induced stator frequency to vary. This relationship for a specific induction generator is shown in Fig 5.

Fig 5- Variation of output frequency with load at constant rotor speed The controls needed to maintain the voltage and frequency of a single-phase induction generator would therefore be very complex and defeat the objective of using the simple machine as a generator. The solution is therefore to use the single-phase induction generator to charge a battery and then to feed the connected load through an inverter. Reference :1. Robinson, L. and Holmes, D.G., (2006). “A Single-phase Self-excited Induction Generator with Voltage and Frequency Regulation for use in a remote area Power Supply”, Proceedings of the Australasian Universities Power Engineering Conference (AUPEC ’06), Melbourne, Australia, 10-13 December 2006, pp 1-6. Web. Retrieved from < http://educypedia.karadimov.info/library/207.pdf >

Read More
Cite this document
  • APA
  • MLA
  • CHICAGO
(“Theory of operation single phase induction generator at load state , Thesis”, n.d.)
Theory of operation single phase induction generator at load state , Thesis. Retrieved from https://studentshare.org/engineering-and-construction/1661912-theory-of-operation-single-phase-induction-generator-at-load-state
(Theory of Operation Single Phase Induction Generator at Load State , Thesis)
Theory of Operation Single Phase Induction Generator at Load State , Thesis. https://studentshare.org/engineering-and-construction/1661912-theory-of-operation-single-phase-induction-generator-at-load-state.
“Theory of Operation Single Phase Induction Generator at Load State , Thesis”, n.d. https://studentshare.org/engineering-and-construction/1661912-theory-of-operation-single-phase-induction-generator-at-load-state.
  • Cited: 0 times

CHECK THESE SAMPLES OF Theory of operation single phase induction generator at load state ,

Circuits with Feedback and Sine Wave Oscillators

The different between the two types of feedback entails whether the feedback signal is out of phase or in phase with an input signal.... Positive or Regenerative feedback is said to occur whenever the feedback signal happens to be in phase with an input signal (Maas 53).... It can be deduced from the diagram that the input signal and the feedback signal are in phase implying that the feedback signal regenerates or adds the input signal....
10 Pages (2500 words) Coursework

Condition of Operation of Single-Phase Induction Generator

Single-phase induction generator must always be excited with a leading voltage.... The working principle of single phase induction generators is similar to that of the three phase induction generators.... This research seeks to critically illustrate the operation of induction motors as generators with particular focus to the conditions of operation of single-phase induction generators as well as the various parameters and characteristics of single-phase induction generators....
12 Pages (3000 words) Thesis

Model and Performance of Single-Phase Induction Generators

It uses analysis mathematical models and equivalent circuits to give more detailed explanation about the steady state and performance of this generator. Engineers have… The unavailability of power in a remote and not easily accessible areas and the issues of power black out that result in need for standby power The single phase induction generator has become one of the devices in consideration to achieve this goal it was explored with a view of bringing cost effective small power generator acceptable to the users....
5 Pages (1250 words) Thesis

FAULT DIAGNOSIS OF AC High Voltages UNDERGROUND CABLES AND SOLUTIONS ANALYSIS TECHNIQUES

This study focused on faults experienced in AC high voltage underground cables and examined the various ways through which they can be identified and corrected.... Wear and tear was found to be one of the major issues leading to electric faults hence power loss.... A lot of… At times, however, the diagnosis differs from the actual problem upon unearthing these cables....
41 Pages (10250 words) Research Paper

Strategic Management of Clothing Stores in the Army

the consolidation of the five clothing stores of the Army into one single store.... Moreover, these theories will be applied or connected with the change that the Army regiment encounters as a result of the consolidation of the five stores into a single entity to cater to the demands of the members of the regiment.... The aim of this paper "Strategic Management of Clothing Stores in the Army" is to analyze and make recommendations on a rather huge organization that is about to encounter a major change in its operation, i....
13 Pages (3250 words) Research Paper

Parameters and Characteristics of Single-phase Induction Generator

According to research findings of the paper “Parameters and Characteristics of Single-phase induction generator”, single-phase inductor generators operate by mechanically turning the rotor of the generators at faster speeds than the synchronous speed in order to produce torque through electromagnetic induction.... Single-phase induction generator must always be excited with a leading voltage.... hellip; Single-phase induction Generators are simple AC motors that employ the principles of induction to derive their power (asynchronous power generation)....
20 Pages (5000 words) Term Paper

Light Background and Interferometry

Additionally, the PSI method overcomes a limitation that requires fringes to have a carrier frequency to resolve the spectral phase slope and reduces the spatial variation in the interferogram background signal.... Monochromatic light is light made of a single wavelength such as laser hence the word mono refers to one.... No light has a definite single frequency.... However, in the late nineteenth century, the new perception of light in terms of wave theory replaced the particle phenomena and still remains....
26 Pages (6500 words) Coursework

Restricted Earth Fault Protection System

he impedance may be a low resistance, high resistance or by combining resistance and induction.... The paper describes a core idea of such a method and its operation illustrated via a diagram.... However, the part needs to coordinate with any other protection thus; there need be noIntentional delay for operation....
8 Pages (2000 words) Case Study