The voltage should be clean, steady and have a known value. A linear voltage is regulator is often used to create a known voltage using a transistor which operates in the regulator’s forward active…
Download full paper File format: .doc, available for editing
GRAB THE BEST PAPER91.6% of users find it useful
Lab report in DC Voltage Regulators
Read Text Preview

Extract of sample "Lab report in DC Voltage Regulators"

Download file to see previous pages

Typically, Zener diodes are intended to offer constant output voltage to a given load connected parallel to it irrespective of the variations in voltage supply or load current fluctuations. The diode regulates the voltage continuously for as long as the current lies below minimum value. The diode allows current to flow forward direction although when a Zener voltage is reached, the current is allowed to flow in the reverse direction. Basically, a voltage regulator is tasked with maintenance of a constant voltage through a load irrespective of variations in applied input voltage as well as variations in load current.

For a conventional Zener diode shunt regulator, the resistor is chosen in such manner that when input voltage is at minimum (VIN(min)) and load current is at maximum (IL(max)), then the current flowing through Zener diode is at minimum (Iz(min)). Then for all other arrangements of input voltage as well as load current, the Zener diode conducts excess current therefore keeping a constant voltage via the load. The Zener transmits the minimum current when loading current is maximum and conducts maximum current when load current is the minimal.

This is a type of voltage regulator used for positive voltage which might be set using selected two resistors that are connected between output and ground. Its capability is often dependent on style made use of. It has many different casing ranging from SOIC-8 to TO-3. Rather than having an Input, an Output and a Ground, it has an Input, an Output and a Reference. Alternatively, when the LM317 is meant to regulate output at 1.25 Volts above Reference pin, the value of the resistor sets current across the resistors.

The current obtained by reference pin is meager and may be ignored for as long as resistor current lies between 1 mA and 10 mA. Giving R1 a standard value, such as 120 or even 240 Ohms, the current is set through R2 also. All one has to do

...Download file to see next pages Read More
Tags
Cite this document
  • APA
  • MLA
  • CHICAGO
(“Lab report in DC Voltage Regulators Assignment Example | Topics and Well Written Essays - 1250 words - 1”, n.d.)
Retrieved de https://studentshare.org/engineering-and-construction/1608050-lab-report-in-dc-voltage-regulators
(Lab Report in DC Voltage Regulators Assignment Example | Topics and Well Written Essays - 1250 Words - 1)
https://studentshare.org/engineering-and-construction/1608050-lab-report-in-dc-voltage-regulators.
“Lab Report in DC Voltage Regulators Assignment Example | Topics and Well Written Essays - 1250 Words - 1”, n.d. https://studentshare.org/engineering-and-construction/1608050-lab-report-in-dc-voltage-regulators.
  • Cited: 1 times

CHECK THESE SAMPLES OF Lab report in DC Voltage Regulators

Differential-Amp Circuits

This is due to the summing point constraints at the lower and upper LM1458C inputs; there is no current is drawn from the signal… These implies that the input impedance is seen by both sources as infinite therefore the output voltage is unaltered by the internal sources impedance, for example V1a=V2b=19.... The potentiometer maintained output voltage at OV when differential input voltage is not applied.... The nulling potentiometer improved common-mode gain of small input voltage by availing even smaller input voltages, V1a=0....
3 Pages (750 words) Lab Report

Electronic Laboratory Practise

The oscilloscope was also used to determine voltage and frequency measurements.... The figure (2) displays the spectrum of DC signal obtained with a peak to peak voltage of 10.... V and root mean square voltage of 3.... DC graph on the oscilloscope when connecting the time base to 50              From the graph, the root mean square voltage was determined to be 61mV while the peak to peak voltage was 300mV....
2 Pages (500 words) Lab Report

Theory of the experiment

The aim of the paper “Theory of the experiment” is to build an amplifier; to evaluate the performance of the built amplifier; to learn the functions of its components through testing; to improve my knowledge and skills of an amplifier through conducting 'real' experiments.... hellip; The author provides the simplest type of audio amplifier....
8 Pages (2000 words) Lab Report

Magnetization on Voltage Using Metals and Semiconductors

The variation of voltage was studied with changing distance and plots were obtained.... The paper "Magnetization on voltage Using Metals and Semiconductors" explains that a voltage is generated in an electrical conductor carrying an electric curren when a magnetic field is applied to it at right angles.... hellip; The author of the paper explains that hall effect is the voltage difference in an electrical conductor which normally occurs when a magnetic field is applied to a rectangular shaped conductor at right angles when it is carrying electric current....
4 Pages (1000 words) Lab Report

Alessandro Giuseppe Antonio Anastasio Volta, and His Contribution To Modern Electrical Understanding

nbsp;… The unit used to measure electric potential difference (voltage) was named after him, i.... This paper ''Alessandro Giuseppe Antonio Anastasio Volta, and His Contribution To Modern Electrical Understanding'' tells that Volta is a famous figure in history due to his several inventions in physics....
5 Pages (1250 words) Report

Basic Lab Instrument Familiarity and Resistor Basics

For resistors in… Therefore, the combined resistance is given by In many electrical circuits, it is important to determine the rate at which The paper “Basic Lab Instrument Familiarity and Resistor Basics" is a forceful variant of a lab report on physics.... Electrical resistance in measured in Ohms, which is the resistance of the conductor in which the current is 1 ampere flows when a voltage of 1 Volt is applied across a conductor (Duncan and Heather 12)....
3 Pages (750 words) Lab Report

Speed Control of a DC and AC Motor Machine

hellip; The components that make up the DC motor including the stator and rotor winding which are separately excited, in this case, have independent dc voltage sources.... A single-phase diode bridge rectifier is used to feed a constant dc voltage to the motor stator.... The author of the "Speed Control of a DC and AC Motor Machine" paper examines speed control of separately excited DC motor by armature voltage variation, operation of a single-phase half controlled bridge rectifier, and waveform of the motor armature voltage operation....
11 Pages (2750 words) Lab Report

Speed Control of DC and AC Machines

rmature winding drives the motor and as a result of varying resistance and voltage properties of the armature will enhance the realization of motor speed control.... Realization is through connecting it to the motor armature voltage supply circuitry.... The paper "Speed Control of dc and AC Machines" highlights that AC machines are able to vary the speed with time increase.... o be able to achieve separate motor excitation of the dc motor, making use of the steady-state conditions is a necessity....
11 Pages (2750 words) Lab Report