Pressure sandwich is a fire fighting phenomenon that involves the exhaustion of the origin of the fire and pressurizing the upper and the lower floors of the fire origin. It involves the pressurization of only the zones that are adjacent to the smoke zone and the exhaustion of…
Download full paper
GRAB THE BEST PAPER
Skip navigation links BFS 3460-08B-2 FIRE PROTECTION SYSTEMS (BFS3460-08B-2)
Read TextPreview

Extract of sample
Skip navigation links BFS 3460-08B-2 FIRE PROTECTION SYSTEMS (BFS3460-08B-2)

Download file to see previous pages... The supply fans of the upper and lower ventilation zones would then be actuated, while the exhaust fans are turned off. These actions would consequently produce a multi-floor sandwich effect in the edifice, and the net effect would be the generation of a pressure variance sandwiched between the hub and boundaries within the Heating Ventilation & Air-Conditioning (HVAC) zone of the fire origin (Brannigan & Corbett , 2008).
Fire alarm plays a very significant role in sandwich pressurization. In exhausting the air from the origin of the fire, the fire floor is likely to drag the fire with it and consequently cause a further spread of the fire before it can be quenched. This is where the fire alarm becomes relevant; it is the fire alarm that assists in actuating the smoke control mode in the event of an inferno. The system then activates the pressurization fans and the fans continue running until the smoke detector supply channel is activated by the fire alarm. It is the fire alarm that aid the initiation of the pressurization system as the process begins when the system receives an actuating signal from the fire alarm in the stairs of the building affected by the fire. Hence fire alarm helps accomplish pressure ...Download file to see next pagesRead More
Comments (0)
Click to create a comment or rate a document
CHECK THESE SAMPLES - THEY ALSO FIT YOUR TOPIC
Skip navigation links BFS 346008B2 FIRE PROTECTION SYSTEMS (BFS346008B2)
1 Pages(250 words)Essay
BFS 346008B2 FIRE PROTECTION SYSTEMS (BFS346008B2)
1 Pages(250 words)Essay
BFS 3460-08B-2 FIRE PROTECTION SYSTEMS (BFS3460-08B-2)
They also need to know the Height and the Area of the building that would be protected from fire hazards as this would enable them to determine the capacity of the fire protection system that would be designed
1 Pages(250 words)Essay
Skip navigation links BFS 3440-07B BUILDING CONSTRUCTION FOR FIRE PROTECTION (BFS3440-07B)
In any preplanning of a building, it is important to take into consideration the nature of each occupancy load of each floor. Given that the first floor will be used for
1 Pages(250 words)Essay
Skip navigation links BFS 3440-07B BUILDING CONSTRUCTION FOR FIRE PROTECTION (BFS3440-07B)
Preplanning a building enhances firefighters’ tactical proficiencies in anticipating the behavior of fire; it helps in preparing for search and rescue of fire victims in the event of a fire outbreak which would definitely improve firefighter safety and survival
1 Pages(250 words)Essay
Skip navigation links BFS 3440-07B BUILDING CONSTRUCTION FOR FIRE PROTECTION (BFS3440-07B)
walls on the other hand are walls that are made of fabric materials that are of lightweight and they are more combustible than bearing walls, unlike the bearing walls they do not prevent the spread of fire in the event of an outbreak. In bearing walls, Fire can only spread
1 Pages(250 words)Essay
Skip navigation links BFS 3440-07B BUILDING CONSTRUCTION FOR FIRE PROTECTION (BFS3440-07B)
The items that should be found during the inspection of a sprinkler system of an organization include: the frame, thermal linkage, a cap, an
1 Pages(250 words)Essay
Skip navigation links BFS 3460-08B-2 FIRE PROTECTION SYSTEMS (BFS3460-08B-2)
High expansion foams can have expansion factors as high as 1100. Our concern is on the low and high expansion types. Low expansion foams are used to extinguish burning flammable or combustible liquid spill and tank fires by
1 Pages(250 words)Essay
Skip navigation links BFS 3460-08B-2 FIRE PROTECTION SYSTEMS (BFS3460-08B-2)
When heated, dry chemical compounds crystallize into a shield-like structure that sticks most efficiently on surfaces such as metals and plastics, effectively stopping the combustion reaction, and blocks the
1 Pages(250 words)Essay
Skip navigation links BFS 3460-08B-2 FIRE PROTECTION SYSTEMS (BFS3460-08B-2)
It has been found however, that Halon agents, not only contributes to the depletion of the ozone layer but also causes potential harm to people exposed to this substance. According to the Material Safety Data Sheet of a fire extinguisher with
1 Pages(250 words)Essay
Let us find you another Essay on topic Skip navigation links BFS 3460-08B-2 FIRE PROTECTION SYSTEMS (BFS3460-08B-2) for FREE!
Contact us:
+16312120006
Contact Us Now
FREE Mobile Apps:
  • About StudentShare
  • Testimonials
  • FAQ
  • Blog
  • Free Essays
  • New Essays
  • Essays
  • The Newest Essay Topics
  • Index samples by all dates
Join us:
Contact Us