Pressure sandwich is a fire fighting phenomenon that involves the exhaustion of the origin of the fire and pressurizing the upper and the lower floors of the fire origin. It involves the pressurization of only the zones that are adjacent to the smoke zone and the exhaustion of…
Download full paperFile format: .doc, available for editing
GRAB THE BEST PAPER93.7% of users find it useful
Skip navigation links BFS 3460-08B-2 FIRE PROTECTION SYSTEMS (BFS3460-08B-2)
Read TextPreview

Extract of sample
"Skip navigation links BFS 3460-08B-2 FIRE PROTECTION SYSTEMS (BFS3460-08B-2)"

Download file to see previous pages The supply fans of the upper and lower ventilation zones would then be actuated, while the exhaust fans are turned off. These actions would consequently produce a multi-floor sandwich effect in the edifice, and the net effect would be the generation of a pressure variance sandwiched between the hub and boundaries within the Heating Ventilation & Air-Conditioning (HVAC) zone of the fire origin (Brannigan & Corbett , 2008).
Fire alarm plays a very significant role in sandwich pressurization. In exhausting the air from the origin of the fire, the fire floor is likely to drag the fire with it and consequently cause a further spread of the fire before it can be quenched. This is where the fire alarm becomes relevant; it is the fire alarm that assists in actuating the smoke control mode in the event of an inferno. The system then activates the pressurization fans and the fans continue running until the smoke detector supply channel is activated by the fire alarm. It is the fire alarm that aid the initiation of the pressurization system as the process begins when the system receives an actuating signal from the fire alarm in the stairs of the building affected by the fire. Hence fire alarm helps accomplish pressure ...Download file to see next pagesRead More
Cite this document
  • APA
  • MLA
  • CHICAGO
(“Skip navigation links BFS 3460-08B-2 FIRE PROTECTION SYSTEMS Essay - 5”, n.d.)
Skip navigation links BFS 3460-08B-2 FIRE PROTECTION SYSTEMS Essay - 5. Retrieved from https://studentshare.org/miscellaneous/1557372-skip-navigation-links-bfs-3460-08b-2-fire-protection-systems-bfs3460-08b-2
(Skip Navigation Links BFS 3460-08B-2 FIRE PROTECTION SYSTEMS Essay - 5)
Skip Navigation Links BFS 3460-08B-2 FIRE PROTECTION SYSTEMS Essay - 5. https://studentshare.org/miscellaneous/1557372-skip-navigation-links-bfs-3460-08b-2-fire-protection-systems-bfs3460-08b-2.
“Skip Navigation Links BFS 3460-08B-2 FIRE PROTECTION SYSTEMS Essay - 5”, n.d. https://studentshare.org/miscellaneous/1557372-skip-navigation-links-bfs-3460-08b-2-fire-protection-systems-bfs3460-08b-2.
  • Cited: 0 times
Comments (0)
Click to create a comment or rate a document
CHECK THESE SAMPLES - THEY ALSO FIT YOUR TOPIC
Skip navigation links BFS 346008B2 FIRE PROTECTION SYSTEMS (BFS346008B2)
...Decibel Ratings Problem: A residence requires smoke alarms within a bedroom and in the corridor directly outside the bedroom. The ambient noise level in the bedroom is 60 dB and a solid core door reduces noise by 25 dB. Determine the minimum decibel ratings for the bedroom smoke alarm and the corridor smoke alarm. According to the NFPA 72 National Fire Alarm Code, the following guidelines for fire alarm decibel ratings must apply: Sleeping area audibility requirements 15 dB above average ambient sound levels, or 5 dB above maximum ambient sound level or 75dB whichever is greater Corridor fire alarms must be audible to all occupants of the floor From this information, we can compute for...
1 Pages(250 words)Essay
BFS 3460-08B-2 FIRE PROTECTION SYSTEMS (BFS3460-08B-2)
...Information that would be missed if only the plumbing drawings were made available to the fire protection system designer Providing only the plumbing drawings of a building are insufficient for a fire protection system designer to design a suitable fire protection system for the building. Apart from the plumbing drawings, the fire protection system designer also needs to know the type of piping system in the building and the type of fluids that these pipes convey. They also need to know the Height and the Area of the building that would be protected from fire hazards as this would enable them to determine the capacity of the fire protection system that would be designed for the building. Fire protection system designers also need... the...
1 Pages(250 words)Essay
Skip navigation links BFS 3440-07B BUILDING CONSTRUCTION FOR FIRE PROTECTION (BFS3440-07B)
... there is limited information given in this situation, it is imperative to assess live loads as close as possible to reality. This would give a crude idea of the dispersal of people in any given building and the maximization of other safety measure that can mitigate any damage, distortion, or discomfort to its occupants. References: Sharry, J. A. (eds.). (1978). Life Safety Code Handbook. Boston, Massachusetts: National Fire Protection Association... load, properly defined, is the weight superimposed by the use and occupancy of any building not including the wind load, earthquake load, or dead load. In contrast to dead load, live load is the probabilistic factor that accounts for occupancy load which then gives the limit or the capacity of...
1 Pages(250 words)Essay
Skip navigation links BFS 3440-07B BUILDING CONSTRUCTION FOR FIRE PROTECTION (BFS3440-07B)
... to have easy access to the building and safely perform fire fighting operation in the event of a fire outbreak. It helps to guarantee that fire fighters would have the upper hand during firefight. Preplanning a building would help the fire protection engineer to effectively coordinate the different types of fire protection systems in the building such as the coordination of fire separations with the architectural designs, the coordination of the smoke control systems with the Heating, Ventilation and air-conditioning systems (HVAC) system, coordination of the fire alarm and the inlet/outlet systems with the security of the building, coordination of the tamper switches and sprinkler system water flow with the fire alarm system... to...
1 Pages(250 words)Essay
Skip navigation links BFS 3440-07B BUILDING CONSTRUCTION FOR FIRE PROTECTION (BFS3440-07B)
...Compare the difference between bearing and non-bearing walls in a structure and how they influence fire fighting tactics during a fire Bearing wallsare load bearing structural elements that are made of heavy materials that are not easily combustible; they have a sufficient fire resistive rating to withstand the effects of fire and consequently prevent the spread of fire in the event of an outbreak. Non-bearing walls on the other hand are walls that are made of fabric materials that are of lightweight and they are more combustible than bearing walls, unlike the bearing walls they do not prevent the spread of fire in the event of an...
1 Pages(250 words)Essay
Skip navigation links BFS 3440-07B BUILDING CONSTRUCTION FOR FIRE PROTECTION (BFS3440-07B)
...Running Head: SKIP NAVIGATION LINKS The items that should be found in a company’s sprinklers systems Most organizations use the fire sprinkler systems so as to minimize the damages that occur as a result of fire. The system allows people to evacuate and contain fires when it occurs. The sprinkler systems used in organizations consists of pipes and sprinklers that are connected to a water supply so as to provide adequate pressure and flow rate to water distributing piping system for the extinguishing fires. The items that should be found...
1 Pages(250 words)Essay
Fire Protection Systems
...Running head: Fire Protection Systems Fire Protection Systems s Fire Protection Systems From man’s birth, Fire is taken as the symbol of life and its scattering red, blue and yellow shades make it a theme of motion, warmth and existence. This blessing of God can be turned into a great menace due to its burning nature. From centuries people became scared of its nature so they started its worship by thinking that it is the manifestation of Goddess anger. It is rightly said that “necessity is the mother of invention”, similarly the damages and distortions related to the...
1 Pages(250 words)Admission/Application Essay
Skip navigation links BFS 3460-08B-2 FIRE PROTECTION SYSTEMS (BFS3460-08B-2)
...to fire and burning material is limited. It acts by halting convection and access to oxygen by steam displacement. This type of foam is used in controlling liquefied natural gas spill fires and helps in dispersing the resulting the vapor cloud. High expansion foams have very low water content making it suitable to use in settings where damage to equipment by water is highly probable. It is also this characteristic that results to a minimum amount of residue thus minimizing post fire clean-up requirements. The National Fire Protection Association has stipulated that this type of systems should completely fill and engulf an area where the...
1 Pages(250 words)Essay
Skip navigation links BFS 3460-08B-2 FIRE PROTECTION SYSTEMS (BFS3460-08B-2)
...Usually in powder form, this agent can effectively extinguish fires because of its solid chemical properties such as its fine particles that can suppress the rapid spread of fire on normal surfaces, that is, surfaces with normal combustibility. Its physical properties also provide an obstruction for oxygen that can feed the fire during combustion. When heated, dry chemical compounds crystallize into a shield-like structure that sticks most efficiently on surfaces such as metals and plastics, effectively stopping the combustion reaction, and blocks the spread of fire on the surface of the ignited material. Fires that involve combustible metals such as...
1 Pages(250 words)Essay
Skip navigation links BFS 3460-08B-2 FIRE PROTECTION SYSTEMS (BFS3460-08B-2)
... system condition (Kidde Aerospace, 2007). Because this agent also effectively cools the temperature of any object it becomes proximate with, the usage of Halon also causes other side effetcs. If Halon comes in contact with the liquid of this product, it will cause frostbite to the eyes. Contact to the skin would also cause frostbite to the skin (Kidde Aerospace, 2007). References: Kidde Aerospace. (2007). Material Data Sheet of a Fire Extinguisher with recylced Halon 1301 and Methanol. Retrieved from: http://www.fenwalsafety.com/Files/KiddeAeroSpace/Global/US-en/Recycled_Halon_1301_&_Methanol_-_KA006_1107.pdf... A Halon in general is any compound in which the hydrogen atoms of a hydrocarbon have been swapped by bromine and other halogen...
1 Pages(250 words)Essay