Standard Imaging Sequences, Image Reconstruction, and Applications - Assignment Example

Summary
The paper "Standard Imaging Sequences, Image Reconstruction, and Applications" is a wonderful example of an assignment on medical science. A homogenous field is the main magnetic field that is present in the MRI, which ensures that the total number of rotations is at the same Larmour frequency within the Z-axis. …
Download full paper File format: .doc, available for editing
GRAB THE BEST PAPER94% of users find it useful

Extract of sample "Standard Imaging Sequences, Image Reconstruction, and Applications"

Standard Imaging Sequences, Image Reconstruction, and Applications Name: Course: Professor: Institution: City & State: Date: Q1 A homogenous field is the main magnetic field that is present in the MRI, which ensures that the total number of rotations is at the same Larmour frequency within the Z-axis. A result, this develops into failure to record any image within the body. This is because the rate at which the body is rotating is the same as that of the process frequencies. From these reasons, it’s clear that the frequency of the nucleus changes with the changing magnetic field. Due to this relationship, the spatial gradients are developed to produce the required echo. Therefore, this ensures that the magnetic field varies linearly to the distance that the field can cover. It also ensures that the rotations that the field creates move at different frequencies thus creating the images with different gradients. Phase encoding and read phase are the two gradients. Phase encoding Phase encoding is the gradient which is applied on the shorter axis. It is usually perpendicular to the read gradient so that it can be able to adjust the spin’s frequency as located on the transverse plane. Frequency changing can be achieved effectively by use of the phase gradient along the Y-axis. The purpose of doing this is to raise or reduce the rotations’ frequencies, based on their position on the phase ground. During the phase encoding, rotations usually undergo dephasing. This results into adjustment of the rotations positioning. The phase gradient randomly turns off when exposed to magnetic field, sending the rotations back to their initial speeds and frequencies. Each twist of the phase angle does not change all together. The phase offset does not change as well. This means that the strength of the gradient is non-existent and hence the central frequency does not change. At the same time, the spin located at the high gradient field fastens while the ones located on the low fields slow down. The signal strength in the midst of the k-space is expected to experience a heightened signal because the gradient field does not exist. The location of the phase direction is also expected to steadily lower the speed of the signal. Every signal that is received is heighted by the echo originating from negative to positive. The values equally increase, in order to fill a single line of k-space. This scenario which is in the phase direction can be described as phase spatially encoding. Spins will then wear off as the gradient becomes stronger. When the RF pulse reaches 900, the phase gradient acquires an unlimited applicability. Varied frequencies are particularly caused by the phase encoding gradient, based on the specific gradient in place. Read gradient A single dimensional image spectrum is usually generated by read encoding gradient, which takes place during echo acquisition. The spin takes off, following turning off of 90o RF pulse. 1800 RF pulse application generates some echo. The frequency gradient keeps of pulsating perpendicularly to the phase gradient as the echo forms. This usually occurs along the axis of the image field. Based on the spin’s location on the gradient, the spin keeps changing frequencies and speeds. Apparently, the whole system can be dephased by gradient’s loss signal when the spins reach the maximum. This is presented as the phase coherent. The phase coherent would be minimized following application of groundwork of gradients’ read from opposite course prior to the read gradient. Minimization in this case depends on the duration that is the same as the start time of the read gradient as well as the center where the signal reaches the maximum. A dephasing of the spin will hereby result from the method used. Afterwards, read gradient is used to put them differently for the utmost warning sign at the echo’s center. This occurs in the read gradients’ foremost half. The spins would begin to diphase slowly after the echo’s center, which occurs during the second read gradients’ half. This means that echo’s formation results from a special encoding which occurs in the frequency direction. Each frequency’s read gradient that is changed is also involved in superimposition. Future record which occurs in the first half of the analysis requires the echo to be measured using the receiver. The read gradient has more stable features, during the phase sequence, which are essential for the whole nation. Q2 The data composed about the echoes from the power caused by the K-space is changed by use of Fourier transformations. Considering that the frequency is a time domain, the final process during which the raw data in the k-space is connected with as per the time domain is given. This shows clearly that that the raw data in the k-space can be decoded into 2 and 3 dimensional images. The raw data results are given by the frequencies encoded, as provided by the gradient’s phase spatially encoding which is found on the phase direction, together with the gradients’ read spatially encoding as positioned on the read direction. Sometimes, shift of the phase can be adjusted. To fill the k-space lines, a common change for the increment on other phase encoding, in every echo acquisition, is equally increased as it gets stepped from negative to positive values. To alter the occurrence of the read direction’s spins, frequency encoding is used during the echo acquisition. Apparently, the materials which are applied here seem like a single spike spectrum. Nevertheless, the information in the k-space is determined by gradient strength multiplied by time. Varied imaging which results from transformations can be solved by converting (m-) to (m) domain by use of a Fourier transformation. In short, this involves changing of time domain to a frequency domain. Both of the Fourier transformations should change the echoes produced from read and phase directions since the k-space is a group of echoes placed horizontally and vertically. The maximum signal is most suitably positioned in the center where there is no signal in the edge and gradient applications are non-existent. Binary numbers are used to represent each echo that is presented in the k-space. It is hard to know whether the frequency of the echo originates from one of the read gradients or both if the read gradients are used in the two dimensions. The fact that k-space consists of two directions, that is phase and read, then two Fourier transformations are essential. A group of profiles of the selected image are produced in the read direction as a result of application of the first Fourier. Fourier transformation is used to transform each echo into a signal file, after which the read direction’s phase is transformed from m- to m domain. The strength of the read direction’s signal produced from the read direction as echoes. In the phase direction, the second Fourier is used to transform the k-space information to information in the phase direction. This means that it can be transformed from m- to m. data points and sine waves are used by Fourier transformation, to establish the position of the each echo’s frequency as represented in the k-space. Following the occurrence of the initial and the subsequent Fourier conversions, an image is formed. In turn, this shows the arrangement of each point corresponding to the arrangement of each position in the excited slice. Q 3 Figure 1: spin echo sequence Spin echo pulse sequence 900 RF pulse Spins that are located in the innermost magnetic turf ought to be in the utmost phase consistency since they are lined up as either anti-corresponding or corresponding with the B0. At this juncture, production of images by the echoes is not expected. As such, a 90o RF Pulse needs to be applied perpendicular to the central magnetic field if any echo is to be generated. Also, Larmour frequency of the chosen slice that has already been altered by the slice selection gradient should be applied. Consequently, flipping of all spins into a new plane, X and Y occurs. It occurs in one direction and causes maximum signal immediately as illustrated in figure 1. The spins will be steady in the slanting plane due to the T2 which is time reliant and the T2* which does not rely on time. Figure 2: Turbo spin echo Slice selection grade Figure 2 illustrates how gradient of the slice selection as an encoding gradient. It is used before, after and during 90o RF pulse along the sample and at some specified time. This creates diverse frequencies in the Z axis. The transformation of the spins is achieved by the means of a linear gradient field along the sample. 900 RF pulse is applied only when the involved slice takes place. Rotation at 900 RF pulse only happens to the protons in the excited slice. It occurs at the transverse plane. The location along the gradient’s slice influences the spin’s frequencies. Hanging on the Bo is likely to occur to those that do not undergo animation and flipping by the 90o RF pulse. The appliance of the slice assortment gradient offers the spin rotational loss. This is harmful as it creates very high signals (Figure 3). Reversing the slice gradients’ phase can cause consistent phase loss. This is done for and period of time, which is equivalent to the time flanked by the 90o RF pulse as well as the very last slice assortment gradient part. Consequently, the incoherent spins’ phase will be overturned and enhanced, therefore the rational phase of the spins besides producing an elevated signal. The application of slice gradient is also done through the 180o RF pulse, but exclusive of reversing (Frank, 1992). Phase gradient Next, spatial gradient with the capacity to transform the spins’ phase is referred to as phase gradient. It is functional anyplace flanked by the 90o RF and the reverberation, but typically prior to the 180o RF pulse in the spin reverberation series. From end to end of the appliance of the phase gradient, the spins will contrast the spins’ rate of recurrence in regard to their location alongside Y direction. A few will progress more rapidly while others will progress slowly. The spins located at the middle of the phase gradient are not changed. Therefore no deplaning occurs. As a consequence, elevated signal in the middle of the k-space is formed. This is used on one occasion in each acquired reverberation or 900 RF pulse and moved starting negative towards positive in equivalent increments to load one line of the reverberation in the k-space (Baert et al., 2011). Putting off the phase gradient returns every frequency to their unique position, retaining the phase shift as a result of manipulation of the major magnetic field. Escalating the phase gradient amplitude reduces the phase consistency hence loss of a signal will take place. 1800 RF pulse 180o RF Pulse which is a radiofrequency is used to overturn and relocate the product of the T2* deplaned to generate an echo. Usually, T2* is time autonomous and results from magnetic field in homogeneity, vulnerability impact or supplementary impacts and does not vary as time goes by. No frequency variation is caused by the 180o RF, but from the transverse plane, it varies the location of the spins. It is used past the first time period (Baert et al., 2011). Read pulse 180o RF Pulse which is a radiofrequency is used to overturn and relocate the product of the T2* deplaned to generate an echo. Usually, T2* is time autonomous and results from magnetic field in homogeneity, vulnerability impact or supplementary impacts and does not vary as time goes by. No frequency variation is caused by the 180o RF, but from the transverse plane, it varies the location of the spins. It is used past the first time period (Baert et al., 2011). Read carriage Read gradient is used at a 90 degree angle to the phase gradient in the course of the acquirement of the reverberation. It bears a linear magnetic field on its read direction which changes the spins ‘rate of recurrence in the transverse plane. This depends on their position in the gradient. A number of them will amplify in terms of velocity whilst some will diminish. The midpoint will not be altered. As a result, the signal is raised in the middle of the k-space. The gradient causes de-phasing in the spins resulting to a loss in the consistent phase. In order to diminish the effect of the inconsistent phase due to the read gradient, there is necessity to prepare a gradient phase. This is used prior to the read gradient within an episode of time corresponding to the time between the first round of the read gradient and the middle of the echo. This will result to failure of phase consistency. The dephasing spins re-phase in the initial half and dephase in the subsequent half when the read gradient is applied. Through the initial half of the read gradient, the signal will accomplish the utmost amplitude at the middle of the echo and then increasingly crumble due to dephasing in the subsequent half. The rise of the phase gradient connecting a negative to a positive 90o RF pulse requires comparable strength of read gradient for the entire spin echo series. Echo All MRI sequences are aimed at aligning the spins in a single direction along the X and Y axis. This produces echoes that obtain meaningful images after further processing. The receiver coiler detects the echo as a voltage which is presented as analogue signal, and eventually transformed into a binary number in the k-space. At the center of the gradient, the echo reaches the maximum. Within every 90o RF pulse, every echo in the spin pulse fills a single line in the k-space. This usually depends on the step or phase gradient slope. At its edges, the k- space will have a low signal, which implies that the detail and resolution while in the center, the signal is higher-this also points out contrast. Low signal emanates from the fact that gradient amplitude is superior in the positive and negative phase gradient edges. A disjointed phase will also result because of negative phase gradient edges in the right and the left of the read gradient. Either a neglected gradient field application in the center of the gradient or its absence causes the soaring signal in the middle of the k-space. This particular echo relies on the T2 decay which is caused by spin-spin interface, and which is time dependent as well. Magnetic moments that are capable of aligning with the magnetic field are produced by the net magnetizations that are used in MRI. During the echo time, the echo is acquired (Suetens, 2002). TE and TR Production of images with a contrast needs these two parameters. TR represents the time between between the successful 90o RF pulses to the next 90o RF pulse (Zlatkin, 2003). The TE represents the time between the 90o RF pulses to the echo’s midpoint as it is established by the receiver. While T1 reduction depends on the TR, the T2 reduction time depends on the TE. References Baert, A. L. et al., 2011. High-Field MR Imaging. 2nd ed. New York: Springer. Frank, J., 1992. Electron Tomography: Three-Dimensional Imaging with the Transmission Electron Microscope. New York: Springer. Holger, P. et al., 1998. The Encyclopedia of Medical Imaging: Musculoskeletal and Soft Tissue Imaging. New York: Taylor & Francis.  Suetens, P., 2002. Fundamentals of Medical Imaging. Cambridge: Cambridge University Press. Zlatkin, B. M., 2003. MRI of the Shoulder. New York: Lippincott Williams and Wilkins. Read More

CHECK THESE SAMPLES OF Standard Imaging Sequences, Image Reconstruction, and Applications

Design And Analysis Of Algorithms For Obtaining Super Resolution Satellite Images

Then it investigates fundamentals of image processing particularly its definition, image perception, image sampling and quantization, image enhancement and image reconstruction from projections.... Researchers have come up with a reconstruction technique known as Super-resolution (SR) technique.... The purpose of this assignment is to develop an algorithm to obtain a HR image from a set of LR images captured by remote sensing satellites.... These algorithms use LR images that are related to each other's through random translations and rotations in order to create a single HR image of the original scene....
18 Pages (4500 words) Essay

The Frequency Encoding Gradients and Phase Encoding Gradients

n the event that the slice is selected, the signal that originates from the slice should always be positioned on both axis of the image.... This paper seeks to respond to a number of questions touching on among other factors, the frequency encoding gradients, phase encoding gradients (question one), Nyquist's theorem (question two), Radiofrequency pulse (RF), the slice select gradient, Readout (frequency encoding) gradient, as well as signal acquisition (question three)....
6 Pages (1500 words) Essay

Parallel Imaging. Advantages And Disadvantages Of Parallel Imaging

They are on the verge of being explored in clinical applications.... This paper seeks to provide an overview of fundamental parallel imaging concepts while illustrating on potential clinical applications.... Described as one with the ability to decrease the time required to perform the image sequence, it causes an increase in the resolution provided there is a specific time measured or be able to perform the two (Boesiger, 2002).... Within the image product, such an advantage can lead to reduced susceptibility, motion artifact, as well as in mitigating of the T2/T2* blurring (Hahn eta l....
16 Pages (4000 words) Assignment

4T MRI Knee Protocol at the Wesley Hospital in Australia

adiographs and CTs remain effective modalities for post-operative imaging following ACL reconstruction.... This paper "4T MRI Knee Protocol at the Wesley Hospital in Australia" seeks to present methods for improving the MR protocol of ACL tears imaging that is used by 4T MRI Siemens scanner at Wesley Hospital in Brisbane for a more accurate diagnosis of the ACL tears.... Ultrasound imaging is utilized minimally together with magnetic resonance imaging when analyzing many knee injuries....
9 Pages (2250 words) Research Proposal

BLIP Echo Planar Imaging Method

It provides high image quality by collecting more averages with increased slice frequency per TR.... variety of tissue contrasts (T1, T2, and T2*) are allowed by EPI for image acquisition, and small structures are imaged using the flexibility in resolution where the field view can be reduced, the echo train length can be increased, or geometric distortions can be reduced to increase the resolution.... Also, just half of the image data can be gathered that can be further synthesized through conjugation to obtain the remaining data....
10 Pages (2500 words) Report

Concepts of Parallel Imaging

They are on the verge of being explored in clinical applications.... Recent studies have hinted that parallel imaging is quite attractive for both vascular and cardiac applications and proves more valuable as a 3-T body.... This paper seeks to provide an overview of fundamental parallel imaging concepts while illustrating potential clinical applications.... It is noted that it has found many applications due to attributed advantages....
12 Pages (3000 words) Report

Advantages of Higher-Field Tesla Scanners

The introduction of 3T scanners in clinical applications has completely changed the way body diagnosis is being done across hospitals the world over.... Faster scans, reduced image degradation, increased contrast between tissues, sub-millimeter resolutions, and much more can be captured with a short period.... Thus the image obtained at 3T scanners is of a higher contrast as opposed to those obtained from previous scanners.... The image below illustrates how images are obtained from various gradients to obtain a clear image (Lutterbey, et al, 2005)....
9 Pages (2250 words) Essay

Echo Planar Image Sequences Data

(7 marks)Echo planar image (EPI) sequences data collection has different ways of comparing with sequences in standard pulse.... (7 marks)Echo planar image (EPI) sequences data collection has different ways of comparing with sequences in standard pulse.... In K space every echo is acquired in a reverse line and before an image is reconstructed an alternative line in K-space must be recorded.... PI is an imaging method that is fats and flexible....
9 Pages (2250 words) Assignment
sponsored ads
We use cookies to create the best experience for you. Keep on browsing if you are OK with that, or find out how to manage cookies.
Contact Us