Fire Safety Management Plan - Literature review Example

Cite this document
Summary
The paper "Fire Safety Management Plan" is a good example of a literature review on the law. There have been legislations and standards that have been set to ensure that cases of fire outbreaks and controlled and in the event of an occurrence, their effect is mitigated…
Download full paper File format: .doc, available for editing
GRAB THE BEST PAPER96.1% of users find it useful

Extract of sample "Fire Safety Management Plan"

Contents Page Introduction 3 Fire safety policy statement 3 Fire safety management structure 4 Evacuation strategies 4 Emergency response 4 Fire alarm and detection 5 Sprinkler system 5 Fire prevention and arson awareness 5 Routine procedures for staff 6 Selection and control of materials 6 Maintenance and testing of fire safety systems 6 Decoration, alterations and extensions 7 Staff training and fire drills 7 Fire risk assessments 8 Duties/Responsibility of the Vice-Chancellor 8 Voice Evacuation 8 Responsibility of the Development and Maintenance Manager 8 The Accommodation, Building and Grounds Manager 9 Safety, Health and Environment Manager 9 Record keeping 9 Audit and updating of this manual 10 References 11 Appendix 1 12 Introduction There have been legislations and standards that have been set to ensure that cases of fire outbreaks and controlled and in the event of occurrence, their effect is mitigated. Fire Safety Order (2005) and BS 9999 (2008) has been instituted to ensure that when designing fire safety plan for Media Factory Building, it complies with the required standards. Based on the above guideline, the report will give the procedure needed to design fire safety plan for Media Factory Building. Fire Safety Policy Statement Fire safety policy statement will be inclusive statement that seeks to detail what Fire Safety Order (2005) defines as responsibility of “responsible person.” Everybody while determining fire safety plan for University of Central Lancashire, will be expected to be in charge of a given responsibility in accordance with articles 8 to 22 of the Fire Safety Order (2005). Diagram for Responsibilities within the University Evacuation Strategy This area has been recognised by BSI (2008) and to mention evacuation strategies within Media Factory Building and the University, the responsible people will be in charge of reports especially when there are incidences of fire The office tasked with evacuation will be mandated to make calls to 122 or 999---depending on the urgency of the matter. The office in accordance with Educational Premises (2006) should ensure constant surveillance Emergency Response According to the standard set by BS 9999 (2008) and articles 8 to 22 of the Fire Safety Order (2005), the staff related to Media House Factory will be tasked with responding to fire alarms and whenever necessary, assemble people at the fire points (British Standard, 2008) According to association for Specialist Fire Protection (2007), the fire marshals available should be able to be deployed according to the emergency of the fire Fire Alarm and Detection In accordance with BS9999 (2008) sub-section dealing with Management of Fire Safety, there are elements that should be considered during fire alarm and detection. These should the responsibility of the office concerned; Creation of awareness among people Increasing probability of the appropriate behaviour so as to reduce threat from fire Fire related materials should be tested periodically Sprinkler System According to BS 9999 (2008) section 3.106 (Sprinkler installation), the institution will be advised to ensure that the systems has control valve set BS 9999 (2008) section 3.107 further explains that there should be means of ensuring that the sprinkler is protected in the premise On variation of guidance, BS 9999 (2008) Section 5 permits variations to be made to travel distances and door and/or stair widths on the basis that the level of risk can be reduced by the provision of additional fire protection measures when Sprinkler System is involved Fire Prevention and Arson Awareness The institution will be responsible for intrusion detection mounted at entrance points There should be installations of gadgets that will detect fire (Arson Prevention Bureau, 1997) The institution and Media Factory Building in particular should have video surveillance and that be checked regularly (HM government, 2007) Routine Procedures for Staff The routine procedures for staff will be to detail responsibility of different staff members within the institution including Media Factory Building. For instance; BS 9999 (2008) section 9 and Fire Safety Order (2005) article 13 explains that when designing Media Factory Building, adequate training of the staff should be considered There should be regular checking of the fire related gadgets to ensure that they are in a good condition In the event of fire, mechanisms should be put in a place that are geared towards the reduction of the spread of fire (HM Government, 2006) Selection and Control of Materials According to clause 39 of the BS 9999 (2008) selection and control of materials will encompass limitation of fire development by the control of materials or the provision of automatic suppression systems When designing fire safety plan for the University, articles 8 to 22 of the Fire Safety Order (2005) and BS 9999 (2008) (Section 2) require that the above named “responsible person” to provide fire control systems S/he will be aiding financial requirement in the institution. The financial stretch of the institution should be governed by Article 17 of the Fire Safety Order (2005). The total number of fire marshals within the compound and those marshalling Media Factory Building are recorded The number of people responsible in the event of fire will have to be put in the record and statistics taken for references Maintenance and Testing of Fire Safety Systems Allocation of the needed funds to cater for assessment of risk as well as provision of requirements for fire safety training To ensure that all gadgets are functioning, track of all statistics related to fire safety within the institution should be taken There should be financing of the needed maintenance to facilitate the needed fire safety systems Decoration, Alterations and Extensions According to the guidelines provided by BS9999 (2008), the university should be told that in most cases, the premises itself do not cause fire but the furnishings and decorations within the said premise. There the standard explains that there need to be enough space so as to minimise the chances of fire spreading in other parts of the buildings Fire Safety Order (2005) further explains that decoration needs to be made with emulsion polish but not wax related polish On the decoration of floor surface, the materials that should be used should not be those that propagate fire in the event of one On maintenance of fire safety equipment and provisions as stipulated in section 43.3 of BS 9999 (2008), alterations additions and repairs have been mentioned. Such should be mandated to competent individuals There should also be periodic inspection of devices and gadgets that are related with safety fire management Staff Training and Fire Drills The institution should be responsible, according to Fire Safety Order (2005) allocate the needed funds to cater for assessment of risk as well as provision of requirements for fire safety training Ensure that staffs handling the materials have the required competencies through formal training Test evacuations or fire drills as explained by BS 9999 (2008) sub-section 44.6 indicates that such should be tested periodically, preferably twice within a period of 12 months. Therefore to ensure the competency staff deployed in the designated zones need to take part in the test process for easy facilitation The function or the basis of fire drills should be set clearly the fire safety manager within the institution There should be identification of weakness in the emergency communications procedures and systems Fire Risk Assessments In the event of assessment, all features related to fire protection in the institution or Media House Factory should be put into consideration Power supply to the third and second floor through lifts should remain usable throughout the time evacuation is required According section 3.70.2 and annex G of the BS 9999 (2008) in the event of fire and the floors are served with lifts then a non-evacuation lift which in this case should be remote from a fire should be used Duties/Responsibility of the Vice-Chancellor According to the guidelines that have been set by BS 9999 (2008) (Section 2) and Fire Safety Order (2005) vice chancellor will be tasked with the following; Develop a working relationship that ensures the policies set within the institution are followed to the latter. Coming up with objectives (both long and short term) that ensure proper management of fire safety. Voice Evacuation This device should be fitted to ensure that once alarm rings it sounds throughout the premise, BSI (2008) (Large Places of Assembly, 2006) Responsibility of the Development and Maintenance Manager The standard set requires the above named to comply with paragraph 1 of the Fire Safety Order (2005) and Section 3: 7.1 of BS 9999 and 13 which both agrees that inspection of the gadgets or fire related material be done periodically In the event of fire, the above named persons will be tasked with the responsibility of raising the alarm Signs that are fire related are supposed to be put at points where they can be easily seen (examples of these signs are attached in appendix 1) The Accommodation, Building and Grounds Manager The personnel or “responsible person” as Safety Order (2005) puts it are expected to uphold article 21 of the Fire Safety Order (2005) by availing necessary measures to control accessibility of the University or Media Factory Building As explained by British Standard (2002), all potential hot spots or ignition points should be under the control of the above named person As also suggested by Protection Association and InFiReS, (2003), they will also be expected to ensure that all flammable objects are kept at bay. This is also related to cleanliness of exit points Safety, Health and Environment Manager S/he should ensure that fire safety plans are put in place before the event of fire When section 3: 7.1 of BS 9999 (2008) is consulted, the persons above should be tasked with the responsibility of inspecting hot spots within the university The buildings within the University or Media Factory Building should be given risk profiles that comply with the emergency plan arrangement (CIBSE, 2010) Record Keeping As required by Fire Safety Order 2005 keeping records of the following information has been deemed necessary; Prepared plans for the salvage in the event of fire Safety measures that have been taken to reduce injury People who are at risk Hazards likely to cause fire Other reasons such as information the institution will need for fire safety management Audit and Updating of this Manual The institution will be expected to be in liaison with the director of estates who ensures that fire risk assessment within the building are audited with certain exceptions carried out through competent persons. References Association for Specialist Fire Protection (2007). Fire resisting ductwork. Second edition. Aldershot: Association for Specialist Fire Protection. Arson Prevention Bureau, (1997). How building design can reduce the threat from arson. London: Arson Prevention Bureau. British Standard (2008). Code of practice for fire safety, in the design, management and use of buildings. London: BSI. P53-238-232-94. British Standard (2002). Fire detection and fire alarm systems for buildings. Code of practice for system design, installation, commissioning and maintenance. London: BSI. P15-16-18 CIBSE (2010). Fire safety engineering- Guide E. London: CIBSE. P78-96-97. Fire Protection Association and InFiReS, (2003). Design guide for the fire protection of buildings – Essential principles. London: Fire Protection Association. HM Government (2007). Fire safety risk assessment, Means of Escape for Disabled People. London: the Department for Communities and Local Government, Eland House. P6-7- 20-21. HM Government (2006). Fire safety risk assessment, large places of assembly. London: the Department for Communities and Local Government, Eland House. P37-109-21-55-56- 112. Appendix 1 FIRE SAFETY MAINTENANCE CHECKLIST Yes No N/A Comments Daily checks (not recorded) Escape routes Can fire exits be opened immediately and easily? Are fire doors clear of obstructions? Are escape routes clear? Fire warning systems Is the indicator panel showing ‘normal’? Escape lighting Are luminaires and exit signs in good condition and undamaged? Do any emergency lights and sign lights have any visible defects ? Firefighting equipment Are fire extinguishers in place? Are fire extinguishers clearly visible? Yes No N/A Comments Read More
Cite this document
  • APA
  • MLA
  • CHICAGO
(Fire Safety Management Plan Literature review Example | Topics and Well Written Essays - 1500 words, n.d.)
Fire Safety Management Plan Literature review Example | Topics and Well Written Essays - 1500 words. https://studentshare.org/law/2049590-fire-safety-management-plan
(Fire Safety Management Plan Literature Review Example | Topics and Well Written Essays - 1500 Words)
Fire Safety Management Plan Literature Review Example | Topics and Well Written Essays - 1500 Words. https://studentshare.org/law/2049590-fire-safety-management-plan.
“Fire Safety Management Plan Literature Review Example | Topics and Well Written Essays - 1500 Words”. https://studentshare.org/law/2049590-fire-safety-management-plan.
  • Cited: 0 times

CHECK THESE SAMPLES OF Fire Safety Management Plan

Fire Safety Management Plan for Student Hub

The paper contains a Fire Safety Management Plan for Student Hub, a busy center for numerous activities in the institution for which are required practical safety procedures.... This Fire Safety Management Plan is produced to comply with the UK standards of Building Regulations.... Hence, many activities like eating and drinking, studying, relaxation and meeting take place there; therefore, it is important that a definite Fire Safety Management Plan be drawn up to provide appropriate safety strategies for students in case of unexpected fire outbreak....
10 Pages (2500 words) Case Study

Design Project: Fire Spread at Whitworth Towers

The author of the paper "Design Project: Fire Spread at Whitworth Towers" outlines that the proposed plan of the building will have a B2 Internal fire spread (linings), B4 External Fire Spread, and researching fire safety/management for a conference room.... A plan has been prepared on these lines as per approved guidelines which covers all the aspects in detail....
8 Pages (2000 words) Report

The University of Central Lancashires Media Factory - Fire Safety Management

As a consultant engaged in the preparation of a Fire Safety Management Plan, the first consideration is given to laws applicable to such as premises which in this case in the Regulatory Reform Order 2005 and a number of guiding documents.... This Fire Safety Management Plan takes into account the most realistic steps to protect occupants and those in the vicinity of the building from the harmful effects of fire.... Moreover, to ensure the validity and reliability of the Fire Safety Management Plan, audit and updating will be conducted particularly when there are alterations or modifications that can greatly affect existing fire safety measures....
6 Pages (1500 words) Case Study

Fire Safety Management and Legislation in Event of an Emergency Service in Media Factory

The need for a Fire Safety Management Plan is a requirement by law.... he need for a Fire Safety Management Plan is a requirement by law.... aking sure of the availability of a Fire Safety Management Plan ... The reason for the preparation of this safety management plan is to acquaint the staff, students, and all other occupants of the media factory with information on fire safety.... The reason for the preparation of this safety management plan is to acquaint the staff, students, and all other occupants of the media factory with information on fire safety....
7 Pages (1750 words) Case Study

Media Building Fire Safety Management Plan

This literature review "Media Building Fire Safety Management Plan" presents fire risk that will be analyzed by the chief fire marshal every year to note the possible points that can result in a fire.... ire safety management structureThe fire safety and management section will have a team that will be looking into the issues regarding fire safety.... This gives the University of Central Lancashire every legal responsibility to make sure that it has an appropriate fire safety plan according to all the rules and regulations about fire as stated in the RR (FS) O 2005 act....
7 Pages (1750 words) Literature review

Aspect of Fire Safety Management

"Fire Safety Management Plan" paper addresses issues on carrying out fire risk assessments; maintain suitable precautions in buildings to secure occupants and rescue procedures.... A Fire Safety Management Plan is developed to assist in managing various programs that prevent fire which has the potential to loss of life, loss of property, and compliance with fire regulations.... he Fire Safety Management Plan has been developed to ensure there is a comprehensive procedure for the fire risk management process that is adopted across the University and the JB Firth Building....
7 Pages (1750 words) Term Paper

The Provision of Fire Safety Systems and Procedures

Everyone in the university, visitors and legal duty to ensure they comply with the law and fire safety provisions stipulated in this Fire Safety Management Plan.... Consequently, the objective of this Fire Safety Management Plan is to avail of an effective fire safety framework that will be employed to secure the safety and well being of every occupant of JB Firth building and to protect the building's assets (Daniel, 2014).... ire safety management Structure ...
6 Pages (1500 words) Assignment

A Fire Safety Plan for the University of Central Lancashire

A Fire Safety Management Plan is important to everyone since it prevents the massive loss of lives and property.... ire safety management is designed for everyone in the schools, within departments, every premises head and those who control all facilities in the university, to always maintain and apply fire safety management objectives within their areas of control and power in the university.... This term paper "A Fire Safety Plan for the University of Central Lancashire" focuses on a fire strategy management plan that seeks to address the issue of fire safety within the Maudland building in the University of Central Lancashire....
10 Pages (2500 words) Term Paper