StudentShare
Contact Us
Sign In / Sign Up for FREE
Search
Go to advanced search...
Free

Structural Design of the Station - Coursework Example

Cite this document
Summary
"Structural Design of the Station" paper explains why is steel preferred for columns. The purpose of column design is to predict that a specific load that makes a column collapse. The adequate factor is kept in consideration during design. This safety factor must be compared with the applied factor…
Download full paper File format: .doc, available for editing
GRAB THE BEST PAPER94.6% of users find it useful
Structural Design of the Station
Read Text Preview

Extract of sample "Structural Design of the Station"

Structural Design of the Station Why is steel preferred for columns? Concrete is a common building material in most super structures today. Despite this fact, concrete has some weakness in its property; it is strong in tension but weak in compression. This property makes concrete bear tensile forces but succumb to compression forces. Because of this weakness, steel is preferred for columns. Steel as a column withstands compression better than concrete. This makes steel qualify as our material for column construction in the station. Why did we use steel columns structural parts of the structure? The benefits linked to steel as a composite material for columns are many and economical. Columns made of steel are slender because material used is strong enough o bear dead and live loads subjected to it. Columns made of other types of material like stone and bricks have a larger cross sectional-area than steel. The large cross-sectional area should be proportional to the column’s length. Although a steel column could be stocky, the strength possessed is greater than that of stone. Through design, slender columns are developed. This type of flexibility is not possible for other materials. The bearing capacity of a stocky column is directly proportional to strength of material as well as cross-sectional area. On loading, a stocky column shortens elastically until an elastic limit is achieved. At this point, an increase in exposure to loads leads to a disproportion in length reduced. This is referred to as the yield point of a column. If loads are increased on the column, it automatically collapses. This behavior is prevalent when the column is short in comparison to its size and cross-sectional area. The failure developed in this particular case is derived from steel as a construction material in compression. The axial load capacity is determined from this formula: Column Axial Load Capacity= Yield Stress of Steel during Compression X Column Cross-sectional Area. Practically, such columns cannot be achieved because high strength in steel needs a column that has a small cross-sectional area. This implies that the commonly used steel columns are slender. This characteristic contrasts that of columns made from weak materials. These columns are stocky and possess a large cross-section. Structural failure related to steel columns is buckling. This mode of failure is related to slender columns. Proportionally casted steel columns buckle before steel’s crushing strength. With gradual increment in compressive strength, a value is achieved at the point when the column buckles and deforms perpendicular to its axis and shortens axially in length. This type of load is the buckling load. On reaching the buckling load, steel columns fail as structural elements and can no longer sustain any load. The purpose of column design is to predict that specific load that will make a column collapse. An adequate safety factor is kept in consideration during design. This safety factor must be compared with the applied factor (tatasteelconstruction). EUROCODE 3-STEEL DESIGN Construction process of steel structures is in four stages: design, construction operation and dismantling. Eurocode Design Manuals provide guidance during design stages on Eurocodes through a theoretical background and provisions in the design codes. Eurocode 3 addresses design of steel structures describing the basics of design, properties of material, geometric qualities and tolerances. The code highlights structural analysis of skeletal structures, and the design of members and components. Structural modeling, global analysis and categories of cross-sections are discussed in the code. Internal forces like tension, bending and shear, compression and torsion forces, and their combination exposed to steel members are considered during design (Luís Simões, Rui & Helena 2010, p. 1.1). EUROCODE 6 - Masonry  Eurocode 6 is a set of guidelines to masonry buildings and civil engineering works (except bridges). Its description contains reinforced, prestressed and confined masonry. It is composed of four parts: regulations for reinforced and unreinforced masonry, structural design for fire, selection and masonry works and calculation methods used for unreinforced concrete masonry structures (Roberts, n.d., Pp.2-6). Materials covered in the code are clay, concrete and stone. Configurations based on proportion, perforation directions, thickness among other factors are made. Compressive strength of masonry in the code considers normal strength for masonry and that of mortar. Designs for mortar have changed because of declaration needs based on strength but not mix proportions (www.eurocode6). Software-Statics 2011 Spatial Framework Programme (6 degrees of freedom per node) is used in solving multi-storey reinforced concrete structures, bearing masonry, metal States, wood members, or members of different bodies of composite materials. Eurocode 2(Opl. Concrete) and Eurocode 8 (Earthquake), and and EC1, EC3, EC5, EC6 provide guidelines for design. The software comprises of: The main body; composed of Reinforced Concrete, Structural Steel, Structural Timber, masonry structures, and combinations thereof (promiscuous Agency) Flexible correction, change, delete, add data after the initial introduction, with auto body recognition Identification panels, plates solving, distribution of loads on beams, continuous beams division, Completely automatic with only one option Special type panels: metal, wooden, metal-concrete composite Description of any type column: rectangular, circular, form C or P (elevator) or T-composite sections consisting of an unlimited number of rectangular columns Description of columns, curved walls, curved beams, and curved edges (contours overhangs, etc.) Description ramp height columns and columns of variable cross-section height Description Multi-sloped roofs on the same floor plan (with different ridges, slopes, contours) Special static points: Joints at ends of beams, columns, change braces and beams and adding user-vertical or horizontal loads in columns (beyond recognized by the program) Special Loads automatically created: Temperature of a structure is considered as uniform change in the whole building, per level, in difference and exit. Fibre sizing beams are placed only at the (and length selected by the user) columns or foundations. The design focuses: Snow Wind (lateral, on the facades of the building, taking away the roof) Land impulses (relaxation-EQ) in basement walls. Differential subsidence is derived from drop support. Technical Report of Static and Antiseismic Calculation with the use program of “Statics 2011” EUROCODE 3(PROGRAMME Results) Proposal Design 1. Assumptions [I]. Materials [II]. Vertical Loads a. Permanent b. Variable IV. Ground V. Conditions OF Environment 2. Technical Information of Bearing Construction The building constitutes common manufactured materials, which is the basic bearing construction of the work. It is composed of reinforced concrete and structural steel while fulfillment materials are of glass and bricks. Horizontal parallel plates constitute basic bearing construction of the individual sandals, monolithically connected with crossed joists and walls, individual sandals and binding joists. Construction of fulfilment is considered in the design process because it transports the vertical loads corresponding to basic bearing construction (Knapton 2003, p.109). 3. Methodology of Analysis The analysis realised is based on the following assumptions: 1. The bearing construction is constituted by members of linear deformity. 2. Construction materials are continuous, homogeneous, and linear and follow Hooke’s law of elasticity from manufactures state. 3. The results of analysis are in effect only for small locomotion so that the phenomenon of 2nd order is ignored. 4. Factors of rigidity are calculated in the non deformed bearing construction, while equations of balance are applied for the deformed position of the bearing construction. The bearing construction is solved as a frame in the space with 6 degrees of freedom per free node. This analysis combined with the method of Locomotion’s. The program “manufactures” the general registration of rigidity of bearing construction and the total registration of charges of the construction. It is created from a linear system of equations (equations of balance). The resolution obtained is equated to locomotion and rotation of the free nodes. An exception is made for the corresponding nodes of the reversed foundation. The corresponding nodes of the foundation can also be cancelled to attain corresponding degrees of freedom. Locomotion of the nodes assists in determining intensive sizes (3 forces and 3 propensities) at the end of each member. Inversion of registration of rigidity is developed with the numerical method Cholleski-Skyline. 3. 1 Slabs Czerny method is used to calculate intensiveness of slabs. The reactions of uniformly loaded slabs are calculated according to a DIN 1045, with geometrical division of the surfaces so that they are distributed as charges of planning in parametric joists(or slabs).The maximum and minimum moments of opening are also calculated (Knapton 2003, p.37). 3.2 Foundations The action of design were calculated in terms of combination of the relation Efd = Efg ± [g] Rd*[O]*Efe Satisfactory intensity for the foundations is in dimensions. This should be received by the ground. Caution is taken to avoid overshooting the bearing capacity of the ground. The moment the bearing is transferred on the ground (which is considered as steadfast support) because of constructional eccentricity and seismic moment, a rotation is triggered in the foundation. This rotation is distributed in elements of rigidity (binding joists and ground) reflected in the Indicator of Resistance of each rotation. Control occurrence at the base column for the moment (ροπή) happens from the turn of the sandal. The resolution of sandals and beams originates from using ground idealisation. This is the model of Winkler (Knapton 2003, p.109). 4. Dimensioning 4.1 Action OF Designing The action of planning is calculated as follows: Sd = 1.35*G + 1.50*Q + 1.50*S Sd = 1.35*G + 1.50*Q + 1.50*W Sd = 1.35*G + 1.35*Q + 1.35*S + 1.35*W Sd = 1.0*G + [ps]2*Q + 0.3*S ± E Where G: Permanent, Q: Mobile, S: Snow, Wa: Wind, E: Earthquake, and The Ψ2 is fixed according to the EC1 4. 2 Elements from Reinforced Concrete Total Resistance method is used for dimensioning. To achieve this, the bearing capacity and the functionalism of the bearing construction in critical cross-sections of all members had controls. The controls countered the revised Regulations for Reinforced Concrete in the following ways: a) Through marginal situations resistance of equitable intensive sizes: moment of bending axial force of slabs, sandals of joists etc b) Through stresses due shearing: twisted beams, binding joists etc c) Through perforation of sandals d) Through buckling and bending of vertical elements and e) Through marginal situations of functionalism of cracking and deformities, arrows of bending (Knapton 2003, p.5). Restriction of big deformities is achieved in most cases through application of constructional provisions of Regulation of Concrete and Steel. It is important to acknowledge that all special controls imposed rely on the new provisions of Eurocodes for all types of elements in construction (multisoft). 4.3 Elements from Steel All dimensions comply with Eurocode 3. Methods stated in the Eurocode were also used for the required controls in bending, shearing, connections and other related issues. Figure : Steel columns ( Statics 2011) Figure : Static analysis ( Statics 2011) Bibliography Knapton, J. (2003). Ground Bearing Concrete Slabs: Specification, Design, Construction and Behaviour. Thomas Telford Publishing Co. Ltd. London. Luís Simões da S., Rui S., Helena G. (2010). Design of Steel Structures; Eurocode 3 Design of Steel Structures, Part 1-1: General Rules and Rules for Buildings. European Convention for Constructional Steelwork (ECCS), Portugal. No Author (n.d.). Eurocode 6: Design of Masonry Structures. Web: http://www.eurocode6.org. Retrieved on 05/05/2012. No Author (n.d.). Behavior of structural members in compression. Web: http://www.tatasteelconstruction.com. Retrieved on 05/05/2012. No Author (n.d.). Statics Eurocode. Web: www.multisoft.gr. Retrieved on 05/05/2012. Roberts, J.J. (n.d.). How to design masonry structures using Eurocode 6: Introduction to Eurocode 6. The Concrete Centre, UK. Read More
Cite this document
  • APA
  • MLA
  • CHICAGO
(Structural Design of the Station Coursework Example | Topics and Well Written Essays - 1750 words, n.d.)
Structural Design of the Station Coursework Example | Topics and Well Written Essays - 1750 words. https://studentshare.org/engineering-and-construction/1774414-change-the-text-that-is-copied-from-internet-some-information-about-steel-brick-in-static-analysis
(Structural Design of the Station Coursework Example | Topics and Well Written Essays - 1750 Words)
Structural Design of the Station Coursework Example | Topics and Well Written Essays - 1750 Words. https://studentshare.org/engineering-and-construction/1774414-change-the-text-that-is-copied-from-internet-some-information-about-steel-brick-in-static-analysis.
“Structural Design of the Station Coursework Example | Topics and Well Written Essays - 1750 Words”. https://studentshare.org/engineering-and-construction/1774414-change-the-text-that-is-copied-from-internet-some-information-about-steel-brick-in-static-analysis.
  • Cited: 0 times

CHECK THESE SAMPLES OF Structural Design of the Station

How WGN changed broadcasting

The letters that are used to abbreviate the name of the station stand for Worlds Greatest Newspaper which was a slogan that was coined by Chicago Tribune.... the station has a radio station with a transmitter that is located in the Elk Grove in Illinois.... the station has been the preferred station by Chicago Cubs, the Northwestern University football besides the men's basketball team from the same university.... the station was found to be favorable for these institutions and sports organization due to the freshness in terms of broadcasting as compared to its peers....
5 Pages (1250 words) Research Paper

CIVIL ENGINEERING Design option Report

The important design considerations that need to be incorporated in the design of station facilities are as follows Incorporation of overall policy of energy efficiency by using energy efficient lighting or using low energy demanding lighting systems could be used to bring down the energy costs at the station significantly.... With the expected passenger volume at the station it is estimated that atleast 1000kW per second could be generated... All the new buildings designed shall confirm to the guidelines proposed for sustainable design of building units, which includes BREEAM standards....
4 Pages (1000 words) Essay

NASAs Value Chain Analysis

According to Michael Porter, the business of a firm can best be determined as a value chain in which total revenues minus total costs of all activities undertaken to develop and market a product or service yields value. Every firm is a synthesis of activities that are performed to design, produce, market, deliver and support its product....
3 Pages (750 words) Essay

Structural engineering

This paper is aimed at expounding on the details of sub-frame structural design.... design moment of beam (and slab) monolithic with its support providing rotational restraint should be that at support face if the support is rectangular and 0.... But the design moment after reduction should not be less than 65% of the support moment.... The structural… Normally continuous beams are analysed as sub-frames by assuming no settlements at supports by walls, columns (or beams) and rotational stiffness by supports provided by The analysis can be done either manually or using commercial software....
4 Pages (1000 words) Essay

Public Affair class summary #5

The design of the story needs to be unique and compelling after conducting research on the targeted audience.... The design of the story needs to be unique and compelling after conducting research on the targeted audience.... An individual who intends to pitch a given TV station has to consider the current rating of that station, as well as the type of programs and news covered in the past....
1 Pages (250 words) Essay

Mechanical cavopulmonary assist device cage for Fontan patients

The elliptical design of the protective cage of filaments not only presents hydrodynamic characteristics but also provides space efficiency.... The proposed design has five basic parts including the protective cage of filaments, the diffuser, the impeller and the catheter.... The outer filament to filament diameter will be designed at 18 Smaller size of the filaments limits the structural support ability of the protective cage while large sizes of the filaments decreases the hydrodynamic properties of the design while increasing the pressure....
5 Pages (1250 words) Research Paper

Structural Analysis

Another important aspect in structural engineering the design.... structural steel beam is simply supported and has a span length of 6m; as shown in Figure 1.... This therefore, makes an I-Section the best beam for structural engineering.... The beam is under perpendicular loadings and also carries a uniformly distributed load of 0....
4 Pages (1000 words) Assignment

Utopia of Glass: Mertins on Glass Train Station

One would imagine the strong vibrations caused by trains on rails shaking the walls of the station, something that would break the glass into pieces.... This article "Utopia of Glass: Mertins on Glass Train station" presents Detlef Mertins as a champion of architectural designs.... The design drawing of the train station in Stuttgart by Mies van der Rohe (1924) gives a classic example of Detlif's treatment of glass architecture.... A train station built of glass?...
1 Pages (250 words) Article
sponsored ads
We use cookies to create the best experience for you. Keep on browsing if you are OK with that, or find out how to manage cookies.
Contact Us