StudentShare
Contact Us
Sign In / Sign Up for FREE
Search
Go to advanced search...
Free

Overload protection systems - Essay Example

Cite this document
Summary
In industrial applications, overload occurs when machines are loaded beyond their capacity leading to breakdown of the machine. For this reasons, machines must be protected against mechanical overloading using overload protection systems…
Download full paper File format: .doc, available for editing
GRAB THE BEST PAPER97.4% of users find it useful
Overload protection systems
Read Text Preview

Extract of sample "Overload protection systems"

? PAPER TOPIC SYSTEM By Overload Protection Systems In industrial applications, overload occurs when machines are loaded beyond their capacity leading to breakdown of the machine. For this reasons, machines must be protected against mechanical overloading using overload protection systems. Depending on the type of overload, the appropriate protection systems are chosen and employed is design of machines. For instance, relays, overload release and circuit breakers are used to protect systems against mechanical overload (Bhalja & Maheshwari, 2011). The most common overload protection systems are mechanical and hydraulic overload protection systems. Mechanical overload protection systems are used in mechanical presses; the working principle is based on a delicate shear plate that requires approximately 130% capacity to be broken. When the shear plate is broken, a slide in position has some space of free distance that allows the press to go through a complete stroke. The shear plate is replaced after each case of overload. Hydraulic overload protection systems are more common because the force of the press can be restricted by controlling the hydraulic pressure, and the press can be restarted after an incidence of overload without having to change the plates (Altan & Tekkaya, 2012). Overload protection systems (a) mechanical (b) hydraulic (Altan & Tekkaya, 2012). The system consists of an oil pad placed between the slide and the connecting rod to which pressure is applied when force is developing. The pressure from the oil is used to move another piston, which acts to intensify the pressurized air. In case the oil pressure (air pressure) exceeds a threshold value, the oil is sapped back into a tank. Therefore, the force applied is restricted and some space is created for free movement (Altan & Tekkaya, 2012). a) Torque guard Torque guards are overload protection devices used in power transmission applications. A spring with a load cam follower placed in a core and detent causes the core and load to rotate jointly. Thus the load always resets in one position and stays in phase when tripped. The system automatically resets when it goes back into the set position after tripping, normally by moving the machine after the overload is cleared. Torque guards assist to protect mechanical systems from damage that may result from extreme torque produced by jamming and overloads. The automatic reset and instant reaction capacity offers consummate guard and reduces down-time. The system disengages at the stipulated torque limit (Grote & Antonsson, 2009). b) Torque limiter A Torque Limiter is a torque overload system consisting of a spring loaded friction style. The load connected to the friction pads is regulated in order to transmit the process torque is transmitted. An overload torque that exceeds the set torque makes the system to slip, preventing overloads from passing through the system. The torque limiter stops slipping when the load drops below the set level, transmitting the torque. In a torque limiter, the phase between input and output is not kept constant. This system can be used in a chain drive with a machined sprocket placed between the friction pads to act as the slip interface so that shutdown and restart is not necessary (Grote & Antonsson, 2009). Torque limiters are regularly used in applications such as conveyor systems, machine tools, and off-highway mobile equipment. c) Axial guard Axial guards are used in systems where the load acts in the linear rather than revolving direction. This overload protection device provides greatly accurate and repeatable trip point. The point of load set is simply adjusted by rotating a screw. The Axial Guard instantly trips when overload occurs and the tie between the load side and drive side is disengaged. The Axial Guard is reset by a slight push or pull in the reverse direction, allowing production to be revived swiftly and downtime to be reduced (Grote & Antonsson, 2009). The mechanical overload system usually operates either by lateral displacement of the interior gearing or free rotation of the primary / intermediate gearbox. Lateral displacement overload systems are frequently used on clarifier drives composed a chain and sprocket set, primary reducer, intermediate reducer, and a spur gear set. The overload system is found on the intermediate gear reducer, usually a worm and worm gear set designed as an internal part of the clarifier drive (Wittbrodt, 2013). During transmission of torque back via the drive, the input worm pinion is made to move sideways with opposition being generated by a spring mechanism. Each torque load on the clarifier is associated with the worm pinion movement. An independent torque monitor device contains a range of limit switches designed to trigger an "alarm" followed by a "shut-off" by closing contacts. Some systems may have a mechanical "shear-pin" placed on the driven sprocket to act as an extra safety device (Altan & Tekkaya, 2012). This pin is made to shear, when a specific torque value is reached, in case the electrical switches do not engage. These overload protection systems provide enough protection to the drive and clarifier, given that they are is correctly set and regularly maintained. The "rotational reducer" overload system was created because many gearbox units in market were not equipped with basic overload devices. In this system, the primary (and sometimes intermediate) gearbox is allowed to rotate under load and the system is made to monitor torque loads on the clarifier. This system operates on a similar design principle as the lateral displacement system; torque is transmitted back via the drive train and the freely rotating reducer as it increases. While the reducer rotates, a plunger is depressed and engages switches situated inside the torque monitor that work on the same principle as those in a lateral displacement system (Vani?c?Ek & Vani?c?Ek, 2008). Rotational overload systems are associated with the common problem of a direct result of unusual loads on the support gearing and bearings which leads to early wear of the intermediate bearings and gears. This leads to incorrect gauge readings and possible failure of the entire overload system. In motor systems, overload occurs when devices are overloaded mechanically past their horsepower rating, causing the motors to draw more current that their ratings. Overload protection is offered at the ends of motor circuit conductors using a motor starter overload device designed to imitate the thermal characteristics of the motors. The condition of overload may not destroy the circuit immediately, but if left to persist for a longer period of time, the excessive current caused by overload conditions may damage the motor and circuits. Electrical connections between overload protection systems and contacts (Senty, 2013). 2. i. A machine is defined as an arrangement of rigid or resistant parts, formed and in a uniform manner such that they move with defined relative movements transmitting force from the source of power to the resistance to be overcome. The two functions of a machine are transmission of force and transmission of definite relative motion. These functions involve rigidity and strength to convey the forces (Vanoff, 2006). ii. When the force applied to a machine can raise a heavier load, the machine saves effort. Mechanical Advantage (MA) refers to the ratio of load to effort in a machine. For a pulley Block with n pulleys, the upper block is fixed to a support while the lower one is movable and the load attached to it. The rope is attached to the lower or upper block, and then passed through a fixed and movable pulley in turn and finally over a fixed pulley. The effort is applied at the free end. The pulleys are assumed to be frictionless and tension round the rope is equally distributed and is equal to the effort. The number of position of the rope in the lower block is r, the total upward force on it is rP and must be equivalent to the load L. Therefore;             rP = L + l, when l, is the weight of the lower block. M.A. = L/P = r- L/p If M.A.>1, the load is greater than effort applied; this implies that the effort can move a heavier load. The greater the mechanical advantage, the less the effort applied to the machine. However, in practical situations, the weight of the machine and friction also affect the load that can be lifted and the mechanical advantage.  Velocity Ratio (VR) of a machine is the ratio of the distance moved by effort to the distance moved by load. For this system, VR = n, (n = number of ropes between the sets of pulleys). The design of machines determines their velocity ration, depending on the friction and the weight of the machines. A velocity ration Read More
Cite this document
  • APA
  • MLA
  • CHICAGO
(“Overload protection systems Essay Example | Topics and Well Written Essays - 1000 words”, n.d.)
Overload protection systems Essay Example | Topics and Well Written Essays - 1000 words. Retrieved from https://studentshare.org/engineering-and-construction/1490865-overload-protection-systems
(Overload Protection Systems Essay Example | Topics and Well Written Essays - 1000 Words)
Overload Protection Systems Essay Example | Topics and Well Written Essays - 1000 Words. https://studentshare.org/engineering-and-construction/1490865-overload-protection-systems.
“Overload Protection Systems Essay Example | Topics and Well Written Essays - 1000 Words”, n.d. https://studentshare.org/engineering-and-construction/1490865-overload-protection-systems.
  • Cited: 0 times

CHECK THESE SAMPLES OF Overload protection systems

Overload protection systems and mechanics of machines

Overload protection systems play a great role in protecting people and equipment from harm that may result from such faults or overloads.... … Overload protection systems normally feature overload switches or relays that serve to cut off power supplies to certain elements of the system and, therefore, prevent the machine from working normally (Gurevich 2003, p.... Overload protection systems play a great role in protecting people and equipment from harm that may result from such faults or overloads....
5 Pages (1250 words) Essay

How Operational Routers May Retain Functionality and How Data May Be Safely Transmitted over Them

The course covered numerous issues related to network security, information assurance, the security vulnerabilities to which systems/data are exposed and the variant strategies/tools for the maximization of security.... The primary aim of the research report is the determination of how operational routers may retain functionality and, more importantly, how data may be safely transmitted over them....
29 Pages (7250 words) Research Paper

Ethics in computing or Data Protection Act

In the database projects, I incorporated technical and procedural controls to protects that data from unauthorized access, malware infections, systems overloads, design flaws and data corruptions.... These activities were carried out with the data protection act in mindData protection requires that comprehensive solution be availed for organizations and individuals to collect and store information in real reliable systems.... To ensure that I never contravened the data protection Act or anybody using the databases does not override the data protection act, I ensured that the available controls provided by the existing file systems are upgraded and if possible combined to improve the level of security of the data (Per Arne Godejord, 2008)....
2 Pages (500 words) Research Paper

Building Services system

The system should serve the general purposes of power in a house including running of two hose reel pumps requiring a total of 2.... kw and a chiller requiring 600A.... These will be the… The type of the power system will be a 3-phase system with a 2,400 V voltage.... The system is efficient and observes all the regulations of the relevant authorities including the engineering code of practice....
12 Pages (3000 words) Essay

Power Quality in Electrical Power System

"Power Quality in Electrical Power systems" paper states that power quality is defined as the limits of electrical properties that allow the electrical systems to work without major power losses in their intended manner.... It is referred to as the electrical load's ability to work efficiently....
6 Pages (1500 words) Coursework

Lightning Protection of Electrical Substations

The writer of the paper “Lightning protection of Electrical Substations” states that the lightning protection measures prescribed in the BS EN/IEC 62305 will help reduce the negative impact of a lightning strike by minimizing the risk of damage and allowing the service to be restored expeditiously.... In addition, the paper examines the recommendation in the standard to the use of co-ordinated surge protection devices with each piece of electrical and electronic equipment in the substation....
37 Pages (9250 words) Thesis

Using Auto-Reclosers And Sectionalizers In Distribution Systems

The paper "Using Auto-Reclosers And Sectionalizers In Distribution systems" analyzes the two automated circuit breakers and discuss their specifications and benefits when applied to the power distribution lines and stations.... The electrical power distribution has evolved in many countries....
6 Pages (1500 words) Research Paper

Problems with Protection Coordination Using Current Magnitudes

The author of the following paper highlights that there are different types of protective coordination systems used to safeguard appliances.... When services have been impaired to a distribution feeder for over twenty minutes or more, it may end up being difficult to re-energize the load without resulting in the operation of the relay systems.... Selectivity of protecting different systems by the overcurrent system works on the basis of sensitivity or operating time (Gers & Holmes, 2008)....
10 Pages (2500 words) Research Paper
sponsored ads
We use cookies to create the best experience for you. Keep on browsing if you are OK with that, or find out how to manage cookies.
Contact Us