The diagram below shows an example of a three phase distribution board An Earth Leakage Circuit Breaker (ELCB) is a device that is used purposefully in detecting current leakages to the earth after an installation has been done. There are types of ELCBs Current Earth Leakage Circuit Breaker (Current-ECLB) It is also known as Residual Current Device (RDC), it involves connecting supply and return circuit conductors with the sensing coil. Therefore, in the event that magnetic field fails to cancel current, the RCD will detect the disproportion and thus trip the contact (Duensing, 2015).
The search coil, neutral coil and phase oil are normally curled on one transformer. The current always passes through supply coil, the load and return back via the neutral coil. The neutral coil and the phase coil are curled in order to emit opposing magnetic flux. Whenever current passes via both the coils, the magnetic impact will be eliminated under the healthy circuit condition (Duensing, 2015). Whenever there is a leakage to earth in the in the load circuit or in between the load circuit and the connection of the RCB circuit, the current flowing back through neutral coil will be able to be reduced.
in the event that the magnetic flux inside the main transformer is disproportional, the sum of the magnetic flux from the other direction will hence not be zero. The difference of the magnetic flux will therefore be known as a residual flux (Duensing, 2015). The changing residual flux in the main transformer normally crosses the route with the curled search coil, resulting to production of the electromotive force (e.m.f) through the search coil. The electromotive force is also known as alternating voltage.
The alternating voltage produces current inside the wiring of the trip circuit. The trip current of the circuit breaker is therefore controlled by this current. The residual magnetic flux is the one responsible for controlling the trip current between neutral and phase coils (Duensing, 2015). The RCDs is divided into different categories based on their sensitivity values which includes; High sensitivity (HS): these are meant for direct contact connections, they range from 6-10-30 mA Medium sensitivity (MS): these are utilized in areas involving moderate connections; the range is from 100-300-500-1000 mA Low sensitivity (LS): mostly applicable in machineries, range as from 3-10-30 A .
Voltage Earth Leakage Circuit Breaker It has a relay coil that is normally connected to the metallic load body at the one end while the other end is connected to the ground wire at the other end. It responsible for detecting currents that are at fault from live wire to the earth wire in the installation circuit it protects. In the event that appropriate voltage is detected via the sense coil in the ELCB, it will automatically put out the power hence remaining off till switch on again. However, a connection from the live wire to any other earthed body is not always detected by this device (Papadopoulos et al., 2013). However, these devices are rarely used today due to the fact that whenever a fault is detected, they end up disconnecting the supply. 4.0 Consider the case of improving the power factor for villa design Power factor basically refers to the relationship between the power utilized by us and the ability to generate and supply this power to every household that needs it.
Also known as the working power and is normally expressed in kilowatts, the total consumption required is often articulated in kilovolt-amperes (Papadopoulos et al., 2013). Therefore, power factor is the ratio of the working power to the total capability required to generate and supply this power to people. In most circumstances, when the power is low, it intends to have negative impact on the lifespan of electrical appliances due to the fact that the excess heat in the electric supply system is brought about by a factor comparable to the square of the current increase especially during nonlinear system load.