Nobody downloaded yet

Fire Protection Hydraulics and Water Supply - Essay Example

Comments (0) Cite this document
Summary
A water distribution system is the systematic arrangement of pipes that are used to convey water strictly for fire fighting, household and industrial purposes. Water distribution systems help to distribute water to the points where they are needed and they are the main network…
Download full paperFile format: .doc, available for editing
GRAB THE BEST PAPER92.9% of users find it useful
Fire Protection Hydraulics and Water Supply
Read TextPreview

Extract of sample
"Fire Protection Hydraulics and Water Supply"

Download file to see previous pages o different parts of a building and for local distribution to the miniature network of pipes in the building and they convey water to these respective regions in large quantities. They are more reliable when two or more primary feeder systems are extended by independent means from the supply source to the most important regions of the municipality (Brannigan & Corbett ,2008).
Secondary feeders are water distribution systems that are made up of network of pipes that are quite smaller in size to the Primary feeder system. They strengthen the water distribution system and are surrounded by different sections of the primary feeder system. The Secondary feeder system helps in the full concentration of water and control the rate of fire flow that is required at a particular region in a building. It is necessary to give two water delivery directions to any spot; hence the secondary feeder system must be arranged in loops (Brannigan & Corbett ,2008).
Distributors are the smallest class of the water distribution system as they consist of much smaller mains when compared to the primary and secondary feeder system. The distributor system is mainly used for specific fire hydrants and individual units of users(Brannigan & Corbett ...Download file to see next pagesRead More
Cite this document
  • APA
  • MLA
  • CHICAGO
(“Fire Protection Hydraulics and Water Supply Essay”, n.d.)
Fire Protection Hydraulics and Water Supply Essay. Retrieved from https://studentshare.org/miscellaneous/1558855-fire-protection-hydraulics-and-water-supply
(Fire Protection Hydraulics and Water Supply Essay)
Fire Protection Hydraulics and Water Supply Essay. https://studentshare.org/miscellaneous/1558855-fire-protection-hydraulics-and-water-supply.
“Fire Protection Hydraulics and Water Supply Essay”, n.d. https://studentshare.org/miscellaneous/1558855-fire-protection-hydraulics-and-water-supply.
  • Cited: 0 times
Comments (0)
Click to create a comment or rate a document
CHECK THESE SAMPLES - THEY ALSO FIT YOUR TOPIC
Fire Protection
...(60), in most cases, fire occurs when the system are not functioning. To counter this problem, fire detection and protection systems have been installed in all business premises in United States of America. There are regulations which require installation of protection gadget to all newly constructed buildings. The installed fire protection must be properly managed and maintained. According to Bettie (60) “there is a code and regulation which requires, inspection, testing, and maintenance of water based fire protection systems” Installation of fire...
16 Pages(4000 words)Research Paper
Fire Protection
...are very important to fire services in their effort to contain fire hazards. Most towns and cities in the world have public fire hydrants, which are the responsibility of the local water authority. However, some buildings, due to their location and nature of occupancy, need to incorporate the private water supply and hydrant systems. It is also important to consider the specifications of the hydrant and match them with the size or functionality of the hose. Another important protection measure is ensuring that a building has firefighter access. The identification and arrival of the fire services at the...
15 Pages(3750 words)Research Paper
Fire Protection Hydraulics and water supply Essay
... the intake valve is opened. Overboard discharge is required to release excess pressure after shut down and pump throttle can be deployed for better supply. Shutting down operations Throttle pump down and disengage by opening the overboard discharge. Limitations of relay operations Total flow of water must not exceed the rated flow of the source engine. Pumped pressure must not exceed the hose test pressure. References IFSTA, Water Supplies for Fire Protection, 4th Edition,Chapter 6 Fire Fighting Apparatus and Procedures, Glencoe Press,3rd Edition, pp. 287-315... What factors should be considered when implementing relay operations Relay operations is a pumping technique used to tackle insufficient fire ground...
1 Pages(250 words)Essay
Water Supply And Fire Protection Hydraulics
...Discuss your understanding of an attack pumper to help solve unusual and complex hydraulic problems on the fire ground. Attacks pumpers are hydraulic devices designed specifically to solve complex problems in hydraulics during firefighting and are constructed to apply water to control fire. Attack pumpers are also used earlier as mini pumpers and required limited staffing to handle fire fighting .It is ideal for attack pumpers to possess fire hose and desired pre-connected lines in order to support the attacks at the fire scene at a faster pace and maneuver the...
2 Pages(500 words)Essay
FIRE PROTECTION HYDRAULICS AND WATER SUPPLY
...How to Change Hose ,Other than 2-inch Hose to Equivalent Lengths of 2-inch Hose Fire hose has consistently been the most used piece of equipment in the fire service. Water is the extinguishing agent most commonly used in fire fighting. Fire hose is the means of changing water from the source to the area of need. Fire hose is commonly available in the following sizes and is measured by internal diameter. (Couvillon, 2006, p33) 3/ 4 inch; 1 inch; 1/ 2 inch;. 2 1/ 2 inch; 3 1/ 2 inch; 4 inch; 5 inch; 6 inch If a length of hose is of a diameter of less than 2 1/ 2 inch. We can determine its equivalent length in 2 ...
2 Pages(500 words)Essay
Fire Protection Assignment
... Problem: Determine whether total flooding or local application is applicable in the following A grease fire in a panin a stove When a grease fire occurs in a pan, local application of fire suppression is enough to address the problem. Putting a lid on the pan should cut and exhaust the fire's oxygen supply. However, when the grease fire spills on the stove and has been left to its destruction for a considerable amount of time, it is recommended to flood the location of the grease fire and the surrounding area especially scorched walls as there may still be sufficient heat and energy to sustain a fire. (Rossotti 2001, p. 15) 2. A coal mine filled with coal dust Local application of fire suppression mechanisms on coal mine fires... is...
1 Pages(250 words)Assignment
Fire Protection Hydraulics and water supply
...Page Fire Protection Hydraulics and water supply Fires and other emergencies take away thousands of lives and destroy properties worth millions of dollars. To reduce the effect, fire service has been established in various localities in the world. Firefighters play a critical role in protecting the public against the dangers by responding to the alarm as fast as possible. This has led to the application of technology in the fire service so as to effectively deal with the disasters (Edwards, 2004). In spite of the increased demand for technology in the fire service, it is...
1 Pages(250 words)Essay
Fire Protection
...FIRE PROTECTION HYDRAULICS AND WATER SUPPLY Hydraulics is the branch of physics which study the mechanical properties of water and other liquids in motion with the application of these properties in engineering. Hydrodynamics is the study of the motion and action of water and other liquids. Hydrostatic is the balance of water and other liquids and the pressure exerted by them at rest. For all intents and purposes hydraulics (Greek: Hydro meaning water; Aulos meaning pipe), as it relates to the fire service is the study of the behaviour of...
4 Pages(1000 words)Essay
Fire Protection Hydraulics and water supply
...Fire Protection Hydraulics and water supply Backpressure is the pressure exerted by a fluid that opposes the forward movement of a hydraulic system. Forward pressure, on the other hand is the pressure exerted by a fluid that opposes the backward movement of a hydraulic system.When the elevation pressure is applied downwards, the forward pressure would tend to elevate the nose, while the backward pressure tends to lower it relative to the pressure source. The elevation pressure could be used to control the backpressure and the forward pressure. The elevation pressure must be increased in order to maintain the level of the...
1 Pages(250 words)Essay
Fire protection
...Fire Protection through Management of Negligence Yonder et al (218) s that prescribed burning is being continuously viewed as a useful but risky tool for land management and conversation. Consequently, they explain that common law aiming at fire management is predicated on negligence rules. According to the European Forest Institute (21), the knowledge about when, where and the reason why fires start is crucial in ensuring appropriate fire management and policy. The Institute argues that capability to comprehend and predict patterns of fire ignition is necessary in helping decision makers enhance fire prevention,...
2 Pages(500 words)Essay
sponsored ads
We use cookies to create the best experience for you. Keep on browsing if you are OK with that, or find out how to manage cookies.
Let us find you another Essay on topic Fire Protection Hydraulics and Water Supply for FREE!
Contact Us