According to the American Wood Council (2003), heavy timber is a type of construction in which fire resistance is attained by placing limitations on minimum sizes on wood structural members and on minimum thickness and composition of wood floors and roofs. On the other hand, a…
Download full paperFile format: .doc, available for editing
GRAB THE BEST PAPER92.1% of users find it useful
BFS 3440-07B BUILDING CONSTRUCTION FOR FIRE PROTECTION (BFS3440-07B)
Read TextPreview

Extract of sample "BFS 3440-07B BUILDING CONSTRUCTION FOR FIRE PROTECTION (BFS3440-07B)"

According to the American Wood Council (2003), heavy timber is a type of construction in which fire resistance is attained by placing limitations on minimum sizes on wood structural members and on minimum thickness and composition of wood floors and roofs. On the other hand, a true mill construction is a special type of heavy timber developed in the textile mills of New England which utilized heavy timber column and beams with cast iron connectors to cover joints where fire might hold, fire barriers enclosing opening between floors, and most importantly, an automatic sprinkler with a water flow alarm and an alarm connection to the fire department (Brannigan, 1992).
According to Brannigan (1992), what seemed to be the deciding factor that would prove that mill construction is superior is that the slow-burning characteristic of heavy timber is of no value once the fire department must fall back to defensive tactics against the fire, and thus heavy timber becomes long burning.
What mill construction techniques provide is a precautionary system to address the fire before it even fans across the building. In contrast to heavy timber which assumes that the thickness and composition of its construction material may well be a hindrance for the progression of fire, mill construction prevents fire before it even begins by placing fire walls that would constrict its spread, not to mention modern automatic sprinklers that extinguish fire almost instantaneously upon detection. Lastly, mill construction provisions recognize that wood assemblies in general are susceptible to combustion and collapse because of the very nature of the material used and thus reinforces it with other safety measure.
References:
Brannigan, F. (1992). Building Construction for the Fire. Subdury, MA: Jones and Bartlett Publishers
American Wood Council. (2003). Heavy Timber Construction. Washington D.C.: American Forest & Paper Association, Inc. Read More
Cite this document
  • APA
  • MLA
  • CHICAGO
(“BFS 3440-07B BUILDING CONSTRUCTION FOR FIRE PROTECTION (BFS3440-07B) Essay - 1”, n.d.)
BFS 3440-07B BUILDING CONSTRUCTION FOR FIRE PROTECTION (BFS3440-07B) Essay - 1. Retrieved from https://studentshare.org/miscellaneous/1556897-bfs-3440-07b-building-construction-for-fire-protection-bfs3440-07b
(BFS 3440-07B BUILDING CONSTRUCTION FOR FIRE PROTECTION (BFS3440-07B) Essay - 1)
BFS 3440-07B BUILDING CONSTRUCTION FOR FIRE PROTECTION (BFS3440-07B) Essay - 1. https://studentshare.org/miscellaneous/1556897-bfs-3440-07b-building-construction-for-fire-protection-bfs3440-07b.
“BFS 3440-07B BUILDING CONSTRUCTION FOR FIRE PROTECTION (BFS3440-07B) Essay - 1”, n.d. https://studentshare.org/miscellaneous/1556897-bfs-3440-07b-building-construction-for-fire-protection-bfs3440-07b.
  • Cited: 0 times
Comments (0)
Click to create a comment or rate a document

CHECK THESE SAMPLES OF BFS 3440-07B BUILDING CONSTRUCTION FOR FIRE PROTECTION (BFS3440-07B)

Fire Protection

...(60), in most cases, fire occurs when the system are not functioning. To counter this problem, fire detection and protection systems have been installed in all business premises in United States of America. There are regulations which require installation of protection gadget to all newly constructed buildings. The installed fire protection must be properly managed and maintained. According to Bettie (60) “there is a code and regulation which requires, inspection, testing, and maintenance of water based fire protection systems” Installation of fire...
16 Pages(4000 words)Research Paper

Building Construction for the Fire Service

...as the fire protection is concerned the building design and type of construction the National Fire Protection Association, (NFPA 220, 2006) has classified into two types, and firstly there are those buildings where the construction material is combustible (wood, steel) and secondly noncombustible for instance concrete and bricks. On the other hand the Association has divided it into five sub categories according to the fire resisting rating and construction methodologies of the structure as a whole. Type I is fire-resistive construction...
6 Pages(1500 words)Research Paper

BFS 346008B2 FIRE PROTECTION SYSTEMS (BFS346008B2)

...August 10, 2009 BSF-3460-08B-2 FIRE PROTECTION SYSTEM (BFS 3460 - 08 B - 2) Problem: Calculate the minimum thrust bearing area for a 16" underground elbow installed in shale. Note: areas in table 4-A have been computed using water pressure of 225 pounds per square inch(15.5 bars) and a soil resistance of 2000 pounds per square foot(1.0bars). The values given in the table include a design safety factor of 1.5. Computations: From Table 4-A, the area of the 16" elbow for a 90 bend A = 32 sq. ft. For other soil composition factors, NFPA 24 requires that the area .of 32 sq. ft be multiplied by a factor of 0.4 for shale Therefore: A = 32.0 (0.4) A = 12.8 sq.ft If we...
1 Pages(250 words)Essay

BFS 3460-08B-2 FIRE PROTECTION SYSTEMS (BFS3460-08B-2)

...Information that would be missed if only the plumbing drawings were made available to the fire protection system designer Providing only the plumbing drawings of a building are insufficient for a fire protection system designer to design a suitable fire protection system for the building. Apart from the plumbing drawings, the fire protection system designer also needs to know the type of piping system in the building and the type of fluids that these pipes convey. They also need to know the Height and the Area of the building that would be protected from fire hazards as this would enable them to determine the capacity of the fire protection system that would be designed for the building. Fire protection system designers also need... the...
1 Pages(250 words)Essay

Skip navigation links BFS 3440-07B BUILDING CONSTRUCTION FOR FIRE PROTECTION (BFS3440-07B)

... there is limited information given in this situation, it is imperative to assess live loads as close as possible to reality. This would give a crude idea of the dispersal of people in any given building and the maximization of other safety measure that can mitigate any damage, distortion, or discomfort to its occupants. References: Sharry, J. A. (eds.). (1978). Life Safety Code Handbook. Boston, Massachusetts: National Fire Protection Association... Live load, properly defined, is the weight superimposed by the use and occupancy of any building not including the wind load, earthquake load, or dead load. In contrast to dead load, live load is the probabilistic factor that accounts for occupancy load which then gives the...
1 Pages(250 words)Essay

Skip navigation links BFS 3440-07B BUILDING CONSTRUCTION FOR FIRE PROTECTION (BFS3440-07B)

...and the coordination of penetrations of the fire rated assemblies with the ductworks, piping and wiring penetrations. These series of coordination ensures the safety of life and property and maximum protection of the building in the event of a fire outbreak. Planning a building for the prevention of a fire outbreak assists in providing the fire fighting officer with adequate information about the building structure and allows the fire fighting officers to efficiently utilize their resources. Information such as those on the exits, floor layouts and the construction,...
1 Pages(250 words)Essay

Skip navigation links BFS 3440-07B BUILDING CONSTRUCTION FOR FIRE PROTECTION (BFS3440-07B)

.... A fire fighter in fighting a fire must devise a tactic to identify the load-bearing walls and be aware of the dangers that are associated with the failure of the bearing walls (Wallace, 2001). A non-bearing wall is easier to build than bearing walls, a fire fighter must be aware of the fact that non-bearing wall are more likely to be destroyed by fire and could cause the spread of fire; hence they must try to first quench fire from non-bearing walls in the event of an outbreak to prevent the spread of fire and make sure that fire do not spread to the bearing walls as its collapse...
1 Pages(250 words)Essay

Skip navigation links BFS 3440-07B BUILDING CONSTRUCTION FOR FIRE PROTECTION (BFS3440-07B)

.... The opening in the water pipe is at a place where the water comes from which is about half an inch in diameter .It varies from the larger hazardous areas to smaller ones in the sprinklers systems. The detector is used in splattering the water streams from orifice to the pattern that is efficient for suppression of fires (Wallace, and Webber, 2004, p. 285). It is therefore important for all organizations to install the sprinklers systems within their organizations so as to protect themselves as well as their organizations from fires. Sprinklers are of different types, and therefore should be used as per their requirements. References Wallace, M. and Webber, L. (2004). The disaster...
1 Pages(250 words)Essay

BFS 3440-07B BUILDING CONSTRUCTION FOR FIRE PROTECTION (BFS3440-07B)

...face a number of challenges. Some of them are discussed below. 1- The most common challenge is to cope with the smoke. In a high rise structure building, the smoke circulates differently from that of the low rise building. The greater height of the building having a low air pressure allows the smoke to move briskly. Most of the deaths during the fire occur due to the suffocation created by the smoke. When the smoke is inhaled, it can burn the lungs. The smoke obscures the eyesight of the occupants as well as the fire fighters. Both of them can not coordinate and the delay results in the death of the occupants or collapse of the building...
1 Pages(250 words)Essay

Building construction for the fire service

...Building Construction for the Fire Service Building Construction for the Fire Service Significant changes in fire-safety and prevention have continued to attend to the field of building and construction in the course of history. The changes have taken place in various areas including the level of participation in the development or revision of codes, the kind of equipment to be used, and the design of buildings and equipment in terms of dimensions, size, and orientation (Karter, 2001; Craighead, 2009). Concerns over lack of participation by fire fighters,...