Nobody downloaded yet

BFS 3460-08B-2 FIRE PROTECTION SYSTEMS (BFS3460-08B-2) - Essay Example

Comments (0) Cite this document
Summary
Providing only the plumbing drawings of a building are insufficient for a fire protection system designer to design a suitable fire protection system for the building. Apart from the plumbing drawings, the fire protection system designer also needs to know the type of piping…
Download full paperFile format: .doc, available for editing
GRAB THE BEST PAPER98.7% of users find it useful
BFS 3460-08B-2 FIRE PROTECTION SYSTEMS (BFS3460-08B-2)
Read TextPreview

Extract of sample
"BFS 3460-08B-2 FIRE PROTECTION SYSTEMS (BFS3460-08B-2)"

Download file to see previous pages Fire protection system designers also need the drawings of all electrical installations and drawings of the Heating, Ventilation and Air-Conditioning (HVAC) system in the building (Edwards, 2000). Information on electrical installations is also needed as this would help to decide on the most suitable place to put the alarm that would be triggered in the event of a fire outbreak. Information on the HVAC system is also needed in order to know their location and design the smoke detection system in such a way that it does not sense the flue from the HVAC system as smoke from a fire.
The fire protection system designer also needs to have the drawings of strategic areas in the building where the fire protection system would be easily accessible and would then design the protection system, bearing in mind that the system would be placed in this location. The designer would also need to know the number of floors & basement in the building. He also needs to have information on the staircase, structural members, truss construction, the number & size of openings in the exterior walls and the configuration of the ceilings. The designer also needs to know how the building is used and purpose the building is used ...Download file to see next pagesRead More
Cite this document
  • APA
  • MLA
  • CHICAGO
(“BFS 3460-08B-2 FIRE PROTECTION SYSTEMS (BFS3460-08B-2) Essay”, n.d.)
BFS 3460-08B-2 FIRE PROTECTION SYSTEMS (BFS3460-08B-2) Essay. Retrieved from https://studentshare.org/miscellaneous/1556818-bfs-3460-08b-2-fire-protection-systems-bfs3460-08b-2
(BFS 3460-08B-2 FIRE PROTECTION SYSTEMS (BFS3460-08B-2) Essay)
BFS 3460-08B-2 FIRE PROTECTION SYSTEMS (BFS3460-08B-2) Essay. https://studentshare.org/miscellaneous/1556818-bfs-3460-08b-2-fire-protection-systems-bfs3460-08b-2.
“BFS 3460-08B-2 FIRE PROTECTION SYSTEMS (BFS3460-08B-2) Essay”, n.d. https://studentshare.org/miscellaneous/1556818-bfs-3460-08b-2-fire-protection-systems-bfs3460-08b-2.
  • Cited: 0 times
Comments (0)
Click to create a comment or rate a document
CHECK THESE SAMPLES - THEY ALSO FIT YOUR TOPIC
Skip navigation links BFS 346008B2 FIRE PROTECTION SYSTEMS (BFS346008B2)
...Decibel Ratings Problem: A residence requires smoke alarms within a bedroom and in the corridor directly outside the bedroom. The ambient noise level in the bedroom is 60 dB and a solid core door reduces noise by 25 dB. Determine the minimum decibel ratings for the bedroom smoke alarm and the corridor smoke alarm. According to the NFPA 72 National Fire Alarm Code, the following guidelines for fire alarm decibel ratings must apply: Sleeping area audibility requirements 15 dB above average ambient sound levels, or 5 dB above maximum ambient sound level or 75dB whichever is greater Corridor fire alarms must be audible to all occupants of the floor From this information, we can compute for...
1 Pages(250 words)Essay
BFS 346008B2 FIRE PROTECTION SYSTEMS (BFS346008B2)
...August 10, 2009 BSF-3460-08B-2 FIRE PROTECTION SYSTEM (BFS 3460 - 08 B - 2) Problem: Calculate the minimum thrust bearing area for a 16" underground elbow installed in shale. Note: areas in table 4-A have been computed using water pressure of 225 pounds per square inch(15.5 bars) and a soil resistance of 2000 pounds per square foot(1.0bars). The values given in the table include a design safety factor of 1.5. Computations: From Table 4-A, the area of the 16" elbow for a 90 bend A = 32 sq. ft. For other soil composition factors, NFPA 24 requires that the area .of 32 sq. ft be...
1 Pages(250 words)Essay
BFS 3440-07B BUILDING CONSTRUCTION FOR FIRE PROTECTION (BFS3440-07B)
...that would prove that mill construction is superior is that the slow-burning characteristic of heavy timber is of no value once the fire department must fall back to defensive tactics against the fire, and thus heavy timber becomes long burning. What mill construction techniques provide is a precautionary system to address the fire before it even fans across the building. In contrast to heavy timber which assumes that the thickness and composition of its construction material may well be a hindrance for the progression of fire, mill construction prevents fire before it even begins by placing fire walls that would...
1 Pages(250 words)Essay
BFS 3440-07B BUILDING CONSTRUCTION FOR FIRE PROTECTION (BFS3440-07B)
...face a number of challenges. Some of them are discussed below. 1- The most common challenge is to cope with the smoke. In a high rise structure building, the smoke circulates differently from that of the low rise building. The greater height of the building having a low air pressure allows the smoke to move briskly. Most of the deaths during the fire occur due to the suffocation created by the smoke. When the smoke is inhaled, it can burn the lungs. The smoke obscures the eyesight of the occupants as well as the fire fighters. Both of them can not coordinate and the delay results in the death of the occupants or collapse of the building on its occupants. 2- In the high rise structures...
1 Pages(250 words)Essay
Skip navigation links BFS 3460-08B-2 FIRE PROTECTION SYSTEMS (BFS3460-08B-2)
...to fire and burning material is limited. It acts by halting convection and access to oxygen by steam displacement. This type of foam is used in controlling liquefied natural gas spill fires and helps in dispersing the resulting the vapor cloud. High expansion foams have very low water content making it suitable to use in settings where damage to equipment by water is highly probable. It is also this characteristic that results to a minimum amount of residue thus minimizing post fire clean-up requirements. The National Fire Protection Association has stipulated that this type of systems should completely fill and engulf an area where the...
1 Pages(250 words)Essay
Skip navigation links BFS 3460-08B-2 FIRE PROTECTION SYSTEMS (BFS3460-08B-2)
...Usually in powder form, this agent can effectively extinguish fires because of its solid chemical properties such as its fine particles that can suppress the rapid spread of fire on normal surfaces, that is, surfaces with normal combustibility. Its physical properties also provide an obstruction for oxygen that can feed the fire during combustion. When heated, dry chemical compounds crystallize into a shield-like structure that sticks most efficiently on surfaces such as metals and plastics, effectively stopping the combustion reaction, and blocks the spread of fire on the surface of the ignited material. Fires that involve combustible metals such as...
1 Pages(250 words)Essay
Skip navigation links BFS 3460-08B-2 FIRE PROTECTION SYSTEMS (BFS3460-08B-2)
... system condition (Kidde Aerospace, 2007). Because this agent also effectively cools the temperature of any object it becomes proximate with, the usage of Halon also causes other side effetcs. If Halon comes in contact with the liquid of this product, it will cause frostbite to the eyes. Contact to the skin would also cause frostbite to the skin (Kidde Aerospace, 2007). References: Kidde Aerospace. (2007). Material Data Sheet of a Fire Extinguisher with recylced Halon 1301 and Methanol. Retrieved from: http://www.fenwalsafety.com/Files/KiddeAeroSpace/Global/US-en/Recycled_Halon_1301_&_Methanol_-_KA006_1107.pdf... A Halon in general is any compound in which the hydrogen atoms of a hydrocarbon have been swapped by bromine and other halogen...
1 Pages(250 words)Essay
Skip navigation links BFS 3460-08B-2 FIRE PROTECTION SYSTEMS (BFS3460-08B-2)
... of an inferno. The system then activates the pressurization fans and the fans continue running until the smoke detector supply channel is activated by the fire alarm. It is the fire alarm that aid the initiation of the pressurization system as the process begins when the system receives an actuating signal from the fire alarm in the stairs of the building affected by the fire. Hence fire alarm helps accomplish pressure sandwich. Reference Brannigan, F.L., & Corbett G.P. (2008). Building Construction for the Fire Service (4th Edition Ed.). Sudbury, MA: Jones & Bartlett Publishers.... What is pressure sandwich and how can fire alarm accomplish such a feat? Pressure sandwich is a fire fighting phenomenon that...
1 Pages(250 words)Essay
Essay
1 Pages(250 words)Movie Review
Fire Protection Systems
...Fire Protection Systems Number Fire protection systems are systems put in place to prevent/ mitigate the unwanted effects of fire such as loss of lives or damage to property (Duncan, 2001). Fire Alarm Systems A fire alarm system is an electric device which alerts building occupants through visual and audio mechanisms when there is smoke or fire. The alarm systems can be activated automatically such as from smoke detectors, heat detectors and water flow sensors or manually from a fire...
7 Pages(1750 words)Research Paper
sponsored ads
We use cookies to create the best experience for you. Keep on browsing if you are OK with that, or find out how to manage cookies.
Let us find you another Essay on topic BFS 3460-08B-2 FIRE PROTECTION SYSTEMS (BFS3460-08B-2) for FREE!
Contact Us