StudentShare
Contact Us
Sign In / Sign Up for FREE
Search
Go to advanced search...
Nobody downloaded yet

Fire Protection - Building Details and Fire Safety Risk Assessment - Report Example

Cite this document
Summary
This report "Fire Protection - Building Details and Fire Safety Risk Assessment" discusses the Regulatory Reform, under which the building owner should implement general fire precautions associated with detection, fire fighting, escape routes and exits, and mitigation of the effects of fire…
Download full paper File format: .doc, available for editing
GRAB THE BEST PAPER98% of users find it useful

Extract of sample "Fire Protection - Building Details and Fire Safety Risk Assessment"

Download file to see previous pages

There is a duty for building owners or responsible persons to take general fire precautions under Article 8, the Regulatory Reform (Fire Safety) Order 2005. This fire precaution includes those safety measures associated with fire fighting and detection. The paper “Building Details and Fire Safety Risk Assessment”  is a forceful example of a report on engineering and construction. There is a duty for building owners or responsible persons to take general fire precautions under Article 8, the Regulatory Reform (Fire Safety) Order 2005.

This general fire precaution includes those safety measures associated with fire fighting and detection. emergency routes and exits, mitigation of the effects of fire, maintenance of fire safety equipment and devices, and safety of people in case of fire under Article 13. Moreover, building works must comply with the requirements of Schedule 1 and Regulation 7 of the Building Regulations 2010 and may be guided by relevant Approved Documents such as Approved Document B (Fire Safety) Volume 2 for buildings other than dwelling houses.

The structure in this study is a three-story open-space school building with an atrium. The Ground Floor has a floor area of roughly 650 meters, with two lecture theatres, a kitchen, a dining and fuelling area, a cafe and social learning flexible space, several toilets, utility rooms, lifts, and SS Office. There are five stairs leading to the first and second floors. The first floor also contains two lecture theatres, video conferencing rooms, a large open area for student services, learning, and teaching support staff, utility rooms, a faith room, and a number of small group study rooms.

The second floor, on the other hand, contains the library, a large study area, a video editing room, and a small meeting room.Similarly, the kitchen is also vulnerable to the effect of air coming from the atrium with a swing door directly leading to the open space. For additional fire safety, this door should be fitted with an automatic shutter. Moreover, in terms of fire detection and warning, critical areas in the Ground Floor such as the kitchen may benefit from such a device as shown below.

...Download file to see next pages Read More
Cite this document
  • APA
  • MLA
  • CHICAGO
(Fire Protection - Building Details and Fire Safety Risk Assessment Report, n.d.)
Fire Protection - Building Details and Fire Safety Risk Assessment Report. https://studentshare.org/engineering-and-construction/2051778-fire-protection
(Fire Protection - Building Details and Fire Safety Risk Assessment Report)
Fire Protection - Building Details and Fire Safety Risk Assessment Report. https://studentshare.org/engineering-and-construction/2051778-fire-protection.
“Fire Protection - Building Details and Fire Safety Risk Assessment Report”. https://studentshare.org/engineering-and-construction/2051778-fire-protection.
  • Cited: 0 times

CHECK THESE SAMPLES OF Fire Protection - Building Details and Fire Safety Risk Assessment

Fire Engineering

The paper covered the factors determining fire safety in buildings, codes of practice for fire safety, design and performance of fire safety framework, compliance issues by segment, health and safety of building occupants and the insights into fire fighting industry in general in Hong Kong.... The study explores the role of these consultants in ensuring building design, development and sustenance for adherence to fire safety to understand the extent to which fire safety engineering solutions are important in fire engineering today....
37 Pages (9250 words) Literature review

Reducing the Risks of Petrochemical Companies

Name Name of Professor Reducing the Risks of Petrochemical Companies Proposed Guidelines for Use in Industrial Applications Introduction It is generally known that it is impossible to live a life free of risk.... Hazardous wastes, on the other hand, are those which create a considerable risk or possible danger to the health of living beings for these are naturally deadly, constant, and non-degradable.... This convenience, while making petroleum important, also is the root of its risk....
15 Pages (3750 words) Research Paper

Health and Safety Management

Health & Safety and risk assessment 4 BU 022 ASSIGNMENT NO 1 Safety Method Statement [risk assessment] Submitted to Mike Gallanagh Safety Method Statement [risk assessment] The construction industry is currently being recognized as a major economic force.... The project was completed in six months and we will discuss the health and safety issues along with risk management during all activities.... Principles of structural design along with standard code practices are adhered while designing with minimum risk....
8 Pages (2000 words) Essay

Design of Fire Protection Systems for Tall Buildings

Design of fire protection Systems for Tall Buildings And Problems in the light of Case study Index 1.... Design Of fire protection Systems in the light of Standards and Codes 5.... fire protection System 7.... Problems of fire protection systems with WTC Case Study 8.... But detailed studies after the WTC event have shown immense levels of flaws in the fire protection systems of tall buildings.... Firstly the building should be resistant to fire for a certain level which about 3 hrs, this is done to safeguard from the collapse of structure and secondly an effective fire protection system should be in place, which is present for the purpose of detection, fire fighting and for effective evacuation of inhabitants....
24 Pages (6000 words) Essay

The Phoenix Supermarket Fire Incident

Following the incident, the National Institute of Occupational safety and Health and the Phoenix fire Department have both conducted in-depth investigations (NIOSH, 2001).... fire disasters have become common in the recent past often claiming wealth of vast magnitudes, useful records, natural resources, animal lives and worst of all human lives.... fire disasters have often reduced homes, business premises, supermarkets and forests to rubble and ash within record short times....
7 Pages (1750 words) Case Study

Fire and Rescue Risk Management Report

The paper “Fire and Rescue Risk Management Report” focuses on the risk assessment, identification of and potential hazards of fire and humans at risk, defining of preventive, protective, and responding activities and control measures that are needed to mitigate and reduce risks.... In this report we will discuss a significance of modern approaches to risk management in relation to FRSs, and, basing upon a risk assessment technique, will determine a specific strategy for one of the Fire Stations in Lancashire, namely – what activities should be undertaken to reduce the number of fires at the local accommodation centre for students....
9 Pages (2250 words) Coursework

Fire Risk Management in Students' Hostels

The detailed description of activities and responsibilities form a Strategy Action Plan for the authorities responsible for fire safety in our hypothetic students' hostel.... This essay discusses fire risk management in students' hostels.... hellip; Kemshall & Pritchard (1997) argue that the quality of human life is often enhanced by risk-taking: “life without risk would be sterile” (p.... However, one cannot but admit that such risk-taking should be clearly justified and balanced in order to ensure that an individual self, or other people, or the physical environment are not exposed to unnecessary harms....
10 Pages (2500 words) Research Paper

Building Design Practice

"Building Design Practice" paper examines the conversion of fire laboratory into a Lecture theater and fire safety standards, fire safety facilities in the building, fire growth and smoke production and its control, and internal and external fire spread and its control.... fire safety standards work as a tool for lowering the losses both in terms of deaths and injuries to the occupants of the buildings and the material losses as are linked with the incidents like fires in the buildings....
9 Pages (2250 words) Term Paper
sponsored ads
We use cookies to create the best experience for you. Keep on browsing if you are OK with that, or find out how to manage cookies.
Contact Us