Extract of sample "Flame Propagation on Cables"

Flame propagation on cables Name Institution Subject Instructor Date Table of Contents Table of Contents 2 1 Introduction 4 1.1Hypothesis 5 2Procedure 5 2.1Apparatus 5 3Results 6 4 Discussions 8 4.1Sources of errors 9 5Conclusions 9 6 Recommendations 9 Abstract Recently, there has been a concern about the characteristics of the flame propagation of cables. Under normal conditions, it is apparent that the cables when subjected to fire may lead to loading of combustible fire and the toxicity that emerges from the generation of the smoke. Apparently, most buildings are made of a variety of cables. This may cause serious fatalities when they are loaded across the building. This requires that, the cables that have to be used have to meet certain accepted standards in order to enhance the safety of the buildings. In most buildings, the fire retarded cables have been used due to their low cost. In a scenario where the cables are used as a single wire or they are used as bundles, the spread of fire would be minimized to a small area. This would in turn minimize the effects of fire in the building as a result of fire propagation. This paper elucidates the test that was conducted on a 100cm cable single wire in order to determine the level of failure. This was done by using the thermocouple to record the temperature and the Bunsen burner to provide the flame. 1 Introduction The test for the electric cables is conducted so as to obtain their mechanical, physical, chemical and flammable properties so as to gauge the level of their resistance. Despite the fact that the cables are not the main cause of fire, they are subject to the consequences that may arise. This means that, they have to be fitted with fire survival properties (Bertrand, Chaussard, Gonzalez, Lacoue, Mattei, and Such, 2002). Apparently, the cables would respond differently when subjected to heat depending on the materials which they are made of such as PVC or nylon. Cables may contribute to fire by providing new fuel that would enhance combustion, release of toxic gases and propagation of flames that may spread from one area to another area. While testing the properties of cables in flame propagation, the aspects of hazards emanating from their combustion and the fire resistance levels are highlighted. In the design process, it is important to consider the vulnerabilities that may arise. All these factors constitute to the safety of the systems and structures that are set up (Davis, Quinard, and Searby, 2001). The class that categorizes the cable performance of a single wire are governed by IEC 60332-1 and IEC 60332-2. The specimen would deem to have passed the test when the burning would have ceased. The charred part is not less as the 45mm given the lower point of the top clamp which may be estimated to the 440mm that is above the given application of the flame (Davis et al., 2001). The study of cables used in buildings facilitates the fundamentals in the resistance of fire that would lead to the probabilistic assessment of fire safety. 1.1Hypothesis The tilted flame indicated a correlation in the length which had been burned and the propagation of the flame for the wire which was tested. On the other hand, there is no relationship in the materials which have greater burn lengths which have an angle more than 45 degrees. This gives a concern that, it may not be eliminated the wiring strategies that leads to the propagation of fire when subjected to severe conditions. The use of electric cables may be classified as, retarded fire cables on single configuration, flame retarded cables that are based on a given bunch or bundles of configuration and the cables. A cable of 100cm cable vertically and apply a 125mm long flame at an angle of 45 degrees in which the gas burner is placed at the bottom of the cable to heat the cable. 2Procedure 2.1Apparatus Gas burner Digital reader Thermocouple Clamp Figure 1 apparatus set up A one metre cable was placed into the top and bottom of the clamp to ensure they are tight. A distance of 20mm line was marked starting from the top edge of the bottom clamp so as there is a distance of approximately 420mm allowance for burning distance. The Bunsen burner was set to a flame height of about 125mm leaving the inner core to be blue Place a filter paper underneath the cable. The thermocouple was set such that, it touches the top and the bottom of the wire while ensuring the data logger is functioning. The flame was impinged at 45 degrees at the 20mm. The flame was left impinged on the cable for duration of 60 seconds. The temperatures for both thermocouples were recorded after every 15 The cables were observed to see whether the cables actually burned from the top clamp and whether the droplets would really ignite the filter paper. This process is done with different cables. Repeat with a second sample of a different cable. The other remaining samples were inclined at 45 degrees having the widest part being their bottom while observing their behaviour. 3Results From the results, it was evident that the yellow and green stripped cable which was placed vertical failed the test, while the white PVC which was placed vertical and the green and yellow nylon which was placed at an angle of 45 degrees passed the test. The nylon cable that was placed vertically had the longest burnt length. The function analysis carried out at the cables give the damage levels of a given cable. There are a number of electric cables namely the power cable, instrumentation cables and control cables. In case of a fire outbreak, the insulators which are the cables are damaged and may lead to wrong reading of measuring instruments Graph 1 Thermocouple temperature vs. Time of a green and yellow striped nylon (7core)-vertical Graph 2 thermocoupletemperature Vs. temperatue of green and yellow striped nylon(7core)- 45 degrees Graph 3 thermocoupletemperature Vs. Temperature of white pvc (3 core)- vertical Graph 4 thermocoupletemperature Vs. Temperature of white pvc (3 core)- 45 degree angle 4 Discussions It was also observed that in the experiment having green and yellow striped nylon (7core)-vertical, the top temperature was rising gradually and it took more time for it to cease burning making the test to fail. The orientation of the cable also affects the time it takes to cease burning (Bertrand et al., 2002). When the cables are inclined at an angle of 45 degrees, as showed in graphs 2 and 4, the bottom temperatures of the thermocouple increases steadily. This proves the correlation on the 45 degrees angle and the flammability test. Additionally, it gives an indication, that there is no correlation in the materials used in the length of the burn with the flammability test. 4.1Sources of errors There were systematic and absolute errors that occurred during the experiment. Most of the errors emerged due to systematic factors such as, poor calibration of equipments, parallax errors and weather conditions. This experiment may not be efficient in the testing of small wires as a result of the melting points of the conductors when the flame has been applied. 5Conclusions In case there is an underground cable installation, there is a necessity of sealing adequately the penetrations above the ground to counteract the high intensity fires that have a high rate of flame propagation. It is also imperative to have the initial detections that would involve the protection of the underground fires. This may be provided by the accelerator malfunction. 6 Recommendations As a stringent measure that has to be considered in constructions of buildings, the slow propagation rate is needed to install the sprinklers. The slow rise in the temperatures of the thermocouple is an indication that, the heat detectors that are erected in the cable trays may not necessarily indicate the heat detected. It is suggested that, portable cables could be used as the high ventilation rates would have little significant on the horizontal propagation of flame. In such cases, smoke equipment has to be used. References Bertrand, R., Chaussard, R. Gonzalez R., Lacoue. J., Mattei, M. and Such M., 2002. Behaviour of electrical cables under fire conditions, Kerntechnik. Davis, G., Quinard, J. and Searby, G., 2001. A numerical investigation of stretch effects in counterflow premixed laminar flames. Combustion Theory and Modelling, 5(2), pp. 353-362. Read More
Tags
Cite this document
  • APA
  • MLA
  • CHICAGO
(Flame Propagation on Cables Term Paper Example | Topics and Well Written Essays - 1250 words, n.d.)
Flame Propagation on Cables Term Paper Example | Topics and Well Written Essays - 1250 words. https://studentshare.org/engineering-and-construction/2047212-flame-propagation-on-cables
(Flame Propagation on Cables Term Paper Example | Topics and Well Written Essays - 1250 Words)
Flame Propagation on Cables Term Paper Example | Topics and Well Written Essays - 1250 Words. https://studentshare.org/engineering-and-construction/2047212-flame-propagation-on-cables.
“Flame Propagation on Cables Term Paper Example | Topics and Well Written Essays - 1250 Words”. https://studentshare.org/engineering-and-construction/2047212-flame-propagation-on-cables.
  • Cited: 0 times

CHECK THESE SAMPLES OF Flame Propagation on Cables

Merits of News Cycle Reduction

The paper "News Cycle" tells us about television monopoly.... As the world advances, the amount of news or information also increases each second.... During the olden days, it was radio or telephone where the medium of information exchange.... hellip; Thereafter internet came into existence and now there is an immense competition going on between cable news networks and the internet to provide the news and information at the same moment as it happens....
8 Pages (2000 words) Essay

Personal emergency and disaster plan

Students of IUB should be prepared for Natural, Accidental and Intentional Disaster Threats.... Tornadoes, blizzards and thunderstorm, followed by floods are the three major types of natural… Though the level of precipitations is lower in Indiana than in some states farther north, the statewide amount reaches about 40 inches annually....
4 Pages (1000 words) Essay

The Cone Calorimeter Experiment

Fire testing plays a pivotal role in the development of new superior materials as well as enabling fire research engineers study the different effects of fire on materials used for building and construction.... The cone calorimeter is one of the most important equipment for… The equipment is used for measuring and testing the heat release rate of a given sample....
7 Pages (1750 words) Essay

Building an Irish Pub in Rome

In carrying out this task, there are certain features that must be borne in mind, because they will be significant in the Roman context.... One of these is the need to procure licenses from the Italian Government to… Secondly, it also appears likely that it would be necessary to adhere to legislative measures on health and safety as well as other measures; therefore one of the steps identified in the WBS Another essential step in the process would be identifying potential suppliers of refurbishing materials as well as bar and kitchen supplies, so that the bar can be well stocked up before it opens....
9 Pages (2250 words) Case Study

Larry King - a King of the American TV and Radio Broadcasting

This essay discusses Larry King.... This is an American TV and radio host, who began his career in the 1950s and was repeatedly nominated for an Emmy Award, Cable ACE and Peabody.... He became famous for his participation in Larry King Live on CNN, which aired from 1985 to 2009.... hellip; Larry King's span of 25 years with CNN speaks for its own self (Mclaughlin 2001)....
4 Pages (1000 words) Research Paper

The Renovation Plan for Abbey House

This case study "The Renovation Plan for Abbey House" presents a renovation report for Abbey House which is an existing five-story building that was built in 1870.... The building in its original form has mixed masonry external walls, masonry internal walls with the floor being made of timber.... hellip; The University purchased the building with the aim of relocating the overseas marketing headquarters in the building....
9 Pages (2250 words) Case Study

Why and How Oxygen Destroys Your Welding

he welding process involves heating of the metal joints to their melting point by the flame torch formed by the oxidizing gas.... Upon using a moderate or neutral flame on steel surfaces, the metal does experience neither, boiling foaming nor a high rate of sparking.... he difference in flame quality and strength gives a very diverse experience.... Considering the strong carburizing frame populated by a lot of oxygen gas in the mixer to form an oxidizing flame....
6 Pages (1500 words) Essay

Forensic Food Analysis

flame photometry Introduction Sodium and Potassium are two essential elements that perform important biological functions in human body, but they are only required in relatively small quantities.... Sodium plays a critical role of maintaining normal flame photometry Introduction Sodium and Potassium are two essential elements that perform important biological functions in human body, but they are only required in relatively small quantities.... flame photometry is atomic spectroscopy that is used to determine the concentration of alkali metal and alkali earth metals ions like potassium, sodium calcium and lithium....
7 Pages (1750 words) Assignment
sponsored ads
We use cookies to create the best experience for you. Keep on browsing if you are OK with that, or find out how to manage cookies.
Contact Us