"The Use of Standard Fire Curves for Determining Fire Resistance" paper focuses on standard fire curves preferred to be the simplest ways of representing fire by showing the arbitrary relationships between time and temperature; these relationships are independent of conditions of the boundary…
Download full paper File format: .doc, available for editing
GRAB THE BEST PAPER97.4% of users find it useful

Extract of sample "The Use of Standard Fire Curves for Determining Fire Resistance"

Name : xxxxxxxxxxx Institution : xxxxxxxxxxx Course : xxxxxxxxxxx Title : The use of standard fire curves for determining fire resistance Tutor : xxxxxxxxxxx @2010 The use of standard fire curves for determining fire resistance Introduction Standard fire curves are preferred to be the simplest ways of representing fire by showing the arbitrary relationships between time and temperature; these relationships are independent on conditions of boundary and ventilation. Initially they were developed for verification and classification of fire fighting furnace tests of building elements and materials. They do not stand for the actual natural fire. Differences in the speed of heating, strength of the fire and the period between the standardized and the actual fire is likely to result to completely different structural behavior. For instance, a fire with a high temperature can end up spalling concrete and exposing steel reinforcement due to the thermal shock even if the duration exposed is short. However a low temperature fire taking a long period of time can end up in an average temperature which is a bit higher in the concretes hence a great reduction in the strength of the concrete (Armer & O'Dell 2001).. The standard fires also do not stand for the severe most fire situations. The structural members who have adapted the standard fire version are likely not to survive when it comes to the real fire. For example, people have different de vices containing hydrocarbon fuels all in the name of decorations, for instance, electronic devices and some other furniture which hence their fire can be more severe compared to the conventional (Franssen et al 2009). Uses of standard fire curves for determining fire resistance The rating of fire resistance basically means the time for which a passive fire protection can hold a fire resistance standard test. This is simply seen as the measure of time or other criteria which entails other verifications of functionality or fitness for purpose. These standard fire curves are used as a guidance to put up a building with the capability of resisting fire. Buildings should be constructed in columns, walls, floors and other elements which can resist fire or can withstand it for a period of time; this ability is determined by exposure in a furnace to sustain high temperatures. Different temperature-time curves are used internationally depending on the application but all aim towards a common objective. An example below is a curve which evaluates the ISO 834 test, the hydrocarbon fire (ASTM E1529), and external fire exposures to the standard ASTM E119 curve (Grant & Pagni 2000). Temperature-time curves for fire resistance tests The different curves in various countries come as a result of the use of the pipes shield the furnace thermocouples inside the (North American Free Trade Agreement) NAFTA testing laboratories. This slows the time taken for the materials to respond to fire hence a more conservative test. Furnace pressure is also a matter relating to standardized tolerances for testing to attain the ratings of fire-resistance. The figure below is a graph showing European tolerances, subject to NEN-EN 1363-1. The different graphs represent the different levels of rating or the resistance expected from the minimum to the maximum, (American Institute of Architects 2008). Germany’s DINA102 includes an important test for a potential firewall which is however applied on the unexposed side instead of the exposed side. As a result of the large differences in the test regimes all over the world even for the similar products and systems, the organizations which really need to market their products are required to carry out a thorough and wide research based on different countries. The results should be slightly different for the residents to consider the research to be unique. The temperature of the fire in a petrochemical industry exceeds those of the ordinary buildings because of the fuels from the hydrocarbons as it burns hotter and faster compared to other elements. The graph below shows the comparison between the hydrocarbon curve and ASTM119 curve. From the results it is clear that the frames with hydrocarbons burns with the highest degree of temperature compared to the rest (Franssen et al 2009). The information portrayed by this graph should best be put into consideration by those constructing the buildings or equipping them this is because people of today’s generation are carelessly putting up buildings in the name of having fire extinguishers and others are spending all the money equipping their houses and offices with the materials containing hydrocarbons hence when there is a fire outbreak they all burn to ashes. It is necessary that people are informed of the elements which are fire resistance and how to use them to avoid the risks. The fires in tunnels are also complicated, the environment inside a tunnel is known as microclimate. No space fort the heat to escape like in the open environment but fire is contained in a narrow space leading the rapid increase of heat and pressure in a little room for escape and no chance of compartmentalization. This kind of fire burns everything and the heat explodes as it looks for a space to escape through. This requires that the building be allowed enough inner space (Kodur & Structural Engineering Institute 2009). The standardized curves also help in the planning of the building to be put up depending on the intended purpose. For example, those for commercial purpose whereby many of the elements involved contains hydrocarbons, others factors of reducing fire risks should be considered like using building materials which have higher capabilities of resisting fire or putting up many layers though in a well strategized way to prevent the risks of falling. The most important way of planning structures for fire safety is to ensure that the power of the fire resistance of a structure is greater than the harshness of the fire to which it is exposed to. These curves also make it easier to test the strength of the ability of an element to resist fire. This mostly determined by the ability of the structure to resist fire spread, collapse or other failures which are likely to occur when the structure is exposed to fire of any strength or the destructive impacts of the fire or its temperature. All these things are considered by the researchers when gathering information related and are included in the final result, which is in the standard curves (Kodur & Structural Engineering Institute 2009). According to the nature of space together with the use and the expected combustible loading fuel as well as the tolerance of the risks by the jurisdiction, various approaches should be measured with reverence to the choices of load of fire to be applied to the structural elements. The best option to be looked into is the use of the standard time-temperature curve. Most of the nations prefer the International Standard ISO 834 or set their own standards based on the ISO 834. Although United States prefer the ASTM E 119 standard of fire, the ISO 834 is generally comparable although more severe. So the ISO standards time-temperature curve has been adapted by most of the nations. Conclusion The fire risks are affecting the economic status of the economists in various nations and the whole world at large not forgetting the health conditions of the residents. Big businesses are burnt down leading to loses of many properties and many people are also burnt and others have health problems as a result of the pollution caused by the fire (Frolov & Baecher 2006).The philosophers and thinkers are trying to research on ways of overcoming this problem. They have come up with elements and new ways of putting up structures to make them fire resistance or increase the length of time they take to burn. This information is represented in the standard time-temperature curve which shows the length of time an elenmen6t can take to be heated up or to be overcome by the severity of fire. The constructors and architectures should put the information provided in these curves when carrying out their duties so as to reduce or control the occurrence of risks. Bibliography Armer G. & O'Dell T., 2001, Fire, static and dynamic tests of building structures: proceedings of the Second Cardington Conference, Cardington, England, Taylor & Francis, Stoke City. Frolov K. & Baecher G., 2006, Protection of civilian infrastructure from acts of terrorism, Springer, Virginia. Franssen J., Zaharia R., & Kodur V., 2009, Designing Steel Structures for Fire Safety, California: CRC Press. Grant C. & Pagni P., 2000, Fire safety science: proceedings of the first international symposium, Taylor & Francis, Oxford. American Institute of Architects, 2008, Research & design: architectural applications of design and technology research, American Institute of Architects, Michigan Franssen J., Zaharia R., & Kodur V,2000, Designing Steel Structures for Fire Safety, CRC Press, Columbus Kodur V., & Structural Engineering Institute, 2009, Performance-based design of structural steel for fire conditions: a calculation methodology, ASCE Publications, New York. Kodur V., & Structural Engineering Institute, 2009, Fire design of concrete structures: materials, structures and modelling : state-of-art report,: FIB - Féd. Int. du Béton, New Zealand. Read More
Cite this document
  • APA
  • MLA
  • CHICAGO
(The Use of Standard Fire Curves for Determining Fire Resistance Term Paper, n.d.)
The Use of Standard Fire Curves for Determining Fire Resistance Term Paper. https://studentshare.org/engineering-and-construction/2044731-the-use-of-standard-fire-curves-for-determining-fire-resistance
(The Use of Standard Fire Curves for Determining Fire Resistance Term Paper)
The Use of Standard Fire Curves for Determining Fire Resistance Term Paper. https://studentshare.org/engineering-and-construction/2044731-the-use-of-standard-fire-curves-for-determining-fire-resistance.
“The Use of Standard Fire Curves for Determining Fire Resistance Term Paper”. https://studentshare.org/engineering-and-construction/2044731-the-use-of-standard-fire-curves-for-determining-fire-resistance.
  • Cited: 0 times

CHECK THESE SAMPLES OF The Use of Standard Fire Curves for Determining Fire Resistance

Establishing the Price and Quantity of Rainwater Tanks

A competitive market is identified by three main characteristics: many consumers and many sellers, freedom of choice under the umbrella of perfect information, and the assumption that the agents have a rational behavior in determining their choice, which essentially maximizes their self-interests....
7 Pages (1750 words) Essay

The Laboratory Technique to Grade Soil

he particle size distribution is used for gravel and sand size (coarse) particles, which can be separated into different size ranges with a series of sieves of standard aperture openings.... nbsp;… The cone penetrometer test is helpful in determining the liquid limit.... fter making these calculations the results of the sieve analysis are plotted on semi-logarithmic plots known as particle–size distribution curves.... Analysis of these curves helps us to determine the soil gradation of the particular soil....
6 Pages (1500 words) Lab Report

Jominy Hardenability Test

Some of the experimental errors came about due to air resistance, parallax, the heterogeneous trait of the calibration plate, faultiness of the Rockwell scale, and wrong calculation.... nbsp;… The curves have a similar gradient with just a few differences.... This experiment has a various objective, key among them include heating different steels above the temperature of austenitization, quenching the given specimen from one end in order to introduce a gradient of cooling, measuring hardness using the Rockwell scale along the cooled bar length, and comparing the curves of experimental hardenability with the curves of the published hardenability....
8 Pages (2000 words) Lab Report

The Effect of Building Geometry and Fire Location on Smoke Production

… The paper “The Effect of Building Geometry and Fire Location on Smoke Production, a  Smoke Control, use of standard fire curves for determining fire resistance” is a thrilling example of an assignment on environmental studies.... The paper “The Effect of Building Geometry and Fire Location on Smoke Production, a  Smoke Control, use of standard fire curves for determining fire resistance” is a thrilling example of an assignment on environmental studies....
6 Pages (1500 words) Assignment

Fire Dynamics for Firefighters

"fire Dynamics for Firefighters" paper states that if the compartment is unventilated but there is no danger of a backdraft occurring, opening the door does affect the fire conditions momentarily, but the situation soon relaxes.... nbsp;… Extracting smoke from the fire compartment as a part of operational fire fighting would be most beneficial, but it always poses some risks when initiated during the fire....
6 Pages (1500 words) Assignment

A Critical Role of Radiation in Combustion Reactions

In light of the above, radiation is important and plays a critical role in fire spread between neighboring buildings.... Therefore, radiation would cause temperatures to rise in adjacent buildings that were initially not affected by fire, and consequently, result in the ignition of available fuel or combustible materials.... However, radiation becomes important when The requirements for space separation, is nonetheless, important and should be reasonable to reduce fire spread between adjacent buildings....
6 Pages (1500 words) Assignment

Review of Aset and Rset Principle

Various technologies that are employed in this field have exhibited the use of this application through its incorporation in making lives safer.... The management methodology should be proposed within the design taking into account the use that the building is bestowed upon completion and the structure of the building with regard to the materials utilized.... The Available Safe Egress Time or Required Safe Egress Time (ASET RSET) is a preferred choice for fire safety or disaster management owing to its diversity within the fire engineering field....
11 Pages (2750 words) Case Study

Requirement for Space Separation between Buildings

The relevant duration of fire resistance is dictated by the size, use, and height of the building.... The requirement for Space Separation and External Fire spread The requirements for external fire spread as outlined in part B4 of the Building Regulations, as per the standard guidance for England and Wales (ADB, BS9999, BR 187, etc) include the following: The external walls of the building shall have sufficient resistance to stop the fire from spreading to other buildings and over the walls, putting into consideration the position, use, and height of the building (HM Government, 2010)....
12 Pages (3000 words) Coursework