Automatic Fire Sprinkler System - Assignment Example

Cite this document
Summary
The aim of the paper “Automatic Fire Sprinkler System” is to analyze a protective measure against fire that contains water supply and the required pressure and a distribution system. They are mostly used in commercial buildings although nowadays even residential buildings use automatic fire sprinkler…
Download full paper File format: .doc, available for editing
GRAB THE BEST PAPER96.9% of users find it useful
Automatic Fire Sprinkler System
Read Text Preview

Extract of sample "Automatic Fire Sprinkler System"

Automatic Fire Sprinkler SystemIntroductionA fire sprinkler system is a protective measure against fire that contains water supply and the required pressure and a distribution system. They are mostly used in commercial buildings and factories although nowadays even residential buildings use automatic fire sprinkler systems. Fire sprinkler systems contain Isolating valves used to stop water supply. It has a distinct red color and is usually locked to allow free water flow. The valve monitor is used to monitor the state of the isolating valve.

The alarm valve used to control flow of water in the fire sprinkler system. The automatic fire sprinkler system also contains the sprinkler head, alarm tests and a bell (Corinne, 2009).InspectionInspection, testing and maintenance of fire sprinkler systems are critical exercises that should always be done on regular basis to ensure that in case of a fire emergency the sprinkler actually worksInspection FormAutomatic Fire Sprinkler SystemsMonthlyQuarterlySemi-annual AnnualOther ReasonParts      Gauges - Dry, Pre-Action & Deluge    √They should be inspected once every week to make sure that the correct levels of air and pressure is maintained alwaysGauges - Wet Pipe Systems√    Inspection should be done monthly to ensure correct water supply pressure just incase there is a fire emergencyAlarm Devices √   Verification should be done quartely to ensure there is no damage to the devices.

Hydraulic Nameplate √   This need to be inspected quartelyBuildings   √ Inspection should be done annually especially prior to winter to ensure that all openings are working correctlyHangers/Bracing   √ Sprinkler pipe hangers and seismic braces shall be inspected annually.Pipe & Fittings   √ Pipes and fittings should be inspected annually.Sprinkler Heads   √ AnnuallySpare Sprinkler Heads   √ AnnuallyAlarm Devices √   Waterflow alarm devices including, but not limited to, mechanical water motor gongs, vane-type water flow devices, and pressure switches that provide audible or visual signals shall be tested quarterly.

Antifreeze Solution   √ The freezing point of solutions in antifreeze shall be tested annually by measuring the specific gravity with a hydrometer or refractometer and adjusting the solutions if necessary. Gauges    √Gauges shall be replaced every 5 years or tested every 5 years by comparison with a calibrated gauge. Gauges not accurate to within 3 percent of the full scale shall be recalibrated or replaced.Sprinkler Heads    √Sprinklers that have been in service for a long time mostly more than fifty years should be replaced.

Samples should also be taken to testing laboratories to ensure that the sprinkler heads are of desired quality.Sprinkler Heads - Extra High Temp    √Temperature is a key parameter that should always be kept constant. The rigt temperature should therefore be continuously tested.Sprinkler Heads - Fast Response    √They should be tested at ten year intervals to ensure they are working properly.Maintenance      Valves (All Types)   √√(See "Valves" below)Obstruction Investigation    √Systems shall be examined internally for obstructions where conditions exist that could cause obstructed piping.

If the condition has not been corrected or the condition is one that could result in obstruction of piping despite any previous flushing procedures.Control Valves    √Inspection of valves should be done on a weekly basis.Alarm Valves     Inspection for alarms should be on a monthly basis.Check Valves    √Inspection is usually after every five years to ensure proper operation free movement and to ensure that the valves are in good condition.Preaction/Deluge Valves   √ Inspection of pre-action valves is done annuallyDry Pipe Valves/Quick Opening Devices   √ Inspection of dry valves should be done annually to ensure proper functioning.

Backflow Prevention Assemblies   √ Backflow preventers should be inspected annuallyConclusionIt is very critical to have properties to have an efficient sprinkler system. Developers and property owners currently adopt the sprinklers systems because of the following reasons. Building regulations in many local authorities recommend installation of sprinkler system as a precautionary measure in cases of fire emergencies. Insurers also recommend installation of sprinkler systems (Firewize, 2013).

They go extra measures by refusing to insure properties that lack sprinkler systems therefore property owners are forced to install these systems as property protection measures. In cases of business continuity in cases of fire emergencies, it is critical to install sprinkler systems.ReferencesCorinne, W. (2009). Automatic Fire Sprinkler Systems, A good practice guide. Retrieved on 19 May 2013 from: http://www.cieh.org/assets/0/72/758/112684/4a293ad6-6b73-4fc7-bdd9-707e20250fc9.pdf Firewize, (2013).

Automatic Fire Sprinkler System - Flow Test. Retrieved on 19 May 2013 from: http://firewize.com/page/general/automatic-fire-sprinkler-system-flow-test

Read More
Cite this document
  • APA
  • MLA
  • CHICAGO
(“Automatic Fire Sprinkler System Assignment Example | Topics and Well Written Essays - 500 words”, n.d.)
Retrieved from https://studentshare.org/technology/1621721-fire-protection-systems-essay-5-sturzenbecker-m-j-adams-b-burnside-e-eds-2012-fire-detection-and-suppression-systems-4th-ed-stillwater-ok-fire-protection-publications
(Automatic Fire Sprinkler System Assignment Example | Topics and Well Written Essays - 500 Words)
https://studentshare.org/technology/1621721-fire-protection-systems-essay-5-sturzenbecker-m-j-adams-b-burnside-e-eds-2012-fire-detection-and-suppression-systems-4th-ed-stillwater-ok-fire-protection-publications.
“Automatic Fire Sprinkler System Assignment Example | Topics and Well Written Essays - 500 Words”, n.d. https://studentshare.org/technology/1621721-fire-protection-systems-essay-5-sturzenbecker-m-j-adams-b-burnside-e-eds-2012-fire-detection-and-suppression-systems-4th-ed-stillwater-ok-fire-protection-publications.
  • Cited: 0 times

CHECK THESE SAMPLES OF Automatic Fire Sprinkler System

Automated Sprinkler

However, due to the specific requirements of the seedlings, a number of modifications will be made to the system so as to provide the optimum conditions.... Owing to the intricate nature of the plants, the system must be customized to meet the specifications.... This work called "Automated sprinkler" describes landscaping sectors, hydraulic engineering principles.... n automated sprinkler will solve the problem of watering....
5 Pages (1250 words) Essay

Sprinkler Systems and Their Use in the Design for Life Safety

A sprinkler system is typically a device installed within buildings to detect a fire in its early stages.... A sprinkler system is typically a device installed within buildings to detect a fire in its early stages.... Generally, the sprinkler system consists of water supply with control valves and pipes fitted with sprinkler heads.... Worldwide, a number of reports show that a significant number of people survived a fire because of an effective sprinkler system....
8 Pages (2000 words) Term Paper

Fire Protection Engineering: Pressurisation Systems and Sprinkler System Design

The "Fire Protection Engineering: Pressurisation Systems and sprinkler system Design" paper address pressurization and sprinkler systems and how they should be installed in a building in order to reduce loss of life and property damage in the event of a fire outbreak.... A defective system or one that is not properly installed and serviced may have a lot of negative impacts such as wasting water due to leaking or even failing to work when a fire occurs.... Proper functionality can be achieved by regular servicing, maintenance, and testing which helps identify any damaged or defective system (NFPA, 2003)....
10 Pages (2500 words) Term Paper

Engineering Design Project

… @2016AbstractThis report details the design of a fire protection system for a residential building with the dimensions of twenty five meters high with a single staircase.... The report entails the procedure of selection of the most suitable fire @2016AbstractThis report details the design of a fire protection system for a residential building with the dimensions of twenty five meters high with a single staircase.... The report entails the procedure of selection of the most suitable fire protection system from the available systems in the market....
12 Pages (3000 words) Assignment

The Building Environment: Active and Passive Control Systems

ue to the complexity related to different aspects of sprinkler system design and installation, various terms have been defined in NFPA 13.... The main term, sprinkler system is defined as a combination of overhead and underground piping connected a water supply.... Figure 1: Various sources of water supply and attached system attached to sprinkler system (Cote & NFPA, 2003)That rules that address private fire service mains, water storage tank and fire pumps are found in NFPA 20, 22 and 23....
9 Pages (2250 words) Assignment

Fire Protection Systems

The project presents the technical report of the writer comparing two fire protection systems namely the residential sprinkler system and the residential water mist system.... The report will be used to determine the most efficient system that the 25m high residential apartment under construction should be used.... Thus, the information to include in the study will include the operation of each system, the components of each and the design criteria to be considered for the installation in the apartments....
11 Pages (2750 words) Assignment

Residential Fire Sprinkler Systems

… Residential fire sprinkler systems Residential fire sprinkler systems is an Automatic Fire Sprinkler System that has quick response automatic sprinkler heads made for low water pressures and low heat release (International Association of Fire Chiefs, Residential fire sprinkler systems Residential fire sprinkler systems is an Automatic Fire Sprinkler System that has quick response automatic sprinkler heads made for low water pressures and low heat release (International Association of Fire Chiefs, 2016)....
10 Pages (2500 words) Assignment

Academic Building Fire Strategy

In this building, there will be a suitable electrically automatic fire warning system with manual call points located next to exit doors.... In addition, the electric fire warning system should have adequate sounders that are clearly audible throughout the building (Approved Document B).... … The paper "Academic Building fire Strategy" is an engrossing example of coursework on engineering and construction.... The following is a fire strategy for a five-storey building....
15 Pages (3750 words) Coursework
sponsored ads
We use cookies to create the best experience for you. Keep on browsing if you are OK with that, or find out how to manage cookies.
Contact Us