Risk Analysis of High Rise Buildings in Abu Dhabi - Case Study Example

Cite this document
Summary
The paper 'Risk Analysis of High Rise Buildings in Abu Dhabi" is a good example of a management case study. An aerial view of Abu Dhabi reveals a sprawling, modern city with a number of high rise and mid-rise buildings that house offices, hotels, malls, hospitals, government and non-government organisations and whatnot…
Download full paper File format: .doc, available for editing
GRAB THE BEST PAPER92.1% of users find it useful

Extract of sample "Risk Analysis of High Rise Buildings in Abu Dhabi"

Name Report (Risk Management) 15 June 2008 Risk Analysis of High Rise Buildings in Abu Dhabi 1.0 Executive Summary An aerial view of Abu Dhabi reveals a sprawling, modern city with a number of high rise and mid rise buildings that house offices, hotels, malls, hospitals, government and non government organisations and what not. However, the things were always not as posh in this desert city as the modern maps reveal. At one time Abu Dhabi was a mediocre Arab city, which though being of cultural and political importance had little to boast in terms of urban infrastructure. Then came the oil boom and with it came status and opulence. Soon the town planners felt a dire need for modern sky scrapers to house offices and businesses. Further diversification of economy led to rapid growth in all the sectors. Today Abu Dhabi is a modern metropolitan city of immense business importance and relevance. Almost all the major brands and corporate firms have their offices in this important business hub of the Middle East. The aim of this report is to identify and analyse the risk factors in a high rise building at Abu Dhabi so as to facilitate the conception of an Integrated Risk Management Plan that could serve as a blue print for other similar structures. Initial urban development and construction activities in Abu Dhabi were conducted with scant consideration for risk identification and neutralization. However, as the caravan of development moved ahead, Abu Dhabi became a vital cosmopolitan centre of trade and business. Town authorities felt a dire need for assimilating the latest safety measures in all the high rise buildings. This an astute team comprising of experienced risk analysts and well qualified fire and rescue personnel was constituted to analyse the risk factors in a typical high rise building at Abu Dhabi. Table of Contents 1.0 Executive Summary 2 Table of Contents 3 2.0 Introduction 4 3.0 Special Features of the Selected Building 5 4.0 Risk Factors in the Given Building 6 4.1 Number of Floors 6 4.2 Travel Distance 9 4.3 Telephone and Electrical Shafts 9 4.4 Stairways 9 4.5 Storage 9 4.6 Falling Debris 10 4.7 Traffic 10 4.8 Staff 10 5.0 Conclusion 10 6.0 Recommendations 10 Works Cited 12 2.0 Introduction Identification of risk factors assumes special importance when it comes to high rise buildings. Though every fire is a major calamity that may often cost dearly in terms of life and financial assets, fires in the high rise buildings more then often prove to be very difficult to deal with and mostly pose a tough challenge to the fire and rescue professionals (CNN, 2008). It definitely makes sense to identify the risk factors in the high rise buildings well in advance and to eliminate and neutralize them so as to avoid any major conflagration or disaster in the future. As it was practically not possible to scrutinize the risk factors in all the high rise buildings in Abu Dhabi, so a typical high rise building being used as a hotel was selected to serve as a sample for the similar structures for the purpose of risk identification. Integrated Risk Management Plans do have a special importance in the fire and rescue services. Such plans not only help in tackling major disasters and calamities, but their major relevance lies in the fact that they help in avoiding such disasters by identifying all the primary risk factors well in advance. It has been seen that many a times, the reasons and causes that cause major conflagrations in the high rise buildings are often found within them or in their vicinity. The interesting thing is that it costs much less to identify and eliminate these risk factors, when compared to the actual losses incurred due to fire disasters. Thus the main purpose of this report is to identify most of the risk factors in a high rise building at Abu Dhabi so as to make pragmatic recommendations for their removal. 3.0 Special Features of the Selected Building Millennium Hotel is a five star hotel housed in a typical high rise building constructed during the dawn of economic growth in Abu Dhabi. This hotel is situated at one corner of the Sheikh Hamdan bin Mohammad Street and is 54 storeys high. On the right side of the Millennium Hotel is located the Al Hosn Palace while Rehman Plaza is placed to the left of it. The backyard of this five star hotel faces the Cultural Foundation Building. The exist to this hotel opens up to Itihad Square. Any major fire in this hotel could prove to be really disastrous in the sense that it can not only lead to a massive loss of human life but the Al Hosn Palace and Cultural Foundation Building placed adjacent to this hotel are monuments of immense historical and cultural importance. Any fire in this hotel could jeopardize the safety of priceless and rare artefacts, texts and antiques placed in these monuments. The construction on this hotel began in 1997. Though all the relevant guidelines and statutes were adhered to during its construction, yet this hotel does have major safety flaws and lacunas. During the time of its construction, the safety guidelines chalked out by the town planners were not that evolved and seemed pathetic when compared to Western standards. The framework of this hotel is made of heavy duty construction steel coated with a fire proof material. The facade of this high rise building is covered with aluminium panels that are not of fire resistant quality. The glass panes fitted in these panels project outwards and are extremely susceptible to high temperatures. The kitchen of this hotel is located on the 48th floor and also serves as a storage area for grocery and provisions. 4.0 Risk Factors in the Given Building A careful survey and scrutiny of this hotel revealed many hidden and obvious risk factors located both inside and outside of this high rise building. These factors though appeared to be minor had the potential to start or aggravate a fire disaster and definitely need to be dealt with on a priority basis. Some of the risk factors traced in the given high rise building were: 4.1 Number of Floors The biggest challenge that the fire and rescue professionals could come across in the event of a fire in this high rise building was to find out a way to rescue all the guests occupying the upper floors in this hotel (Osho Fact Sheet, 2003). The mere number of floors in this hotel seemed threatening when considering the poor fire proof installations in this building. It was found that not all the floors were equipped with fire escapes and many of them lacked fire extinguishers. The HVAC and electrical shafts on all the floors were also not properly sealed that could aid the horizontal and vertical spread of smoke and flames in the event of a fire. Infact a qualitative and quantitative risk analysis of this high rise building revealed that the guests trapped and the fire fighters operating on the upper floors faced a significant risk to their lives. Graph X reveals that the in case of the guests staying above the 25th floor, the risk to their lives was considerably enhanced owing to the reasons mentioned above. High Risk Low 10 20 25 30 40 50 60 Floors (X) Night High Risk Day Low 10 20 30 40 50 55 60 Floors (Y) A careful analysis of the graph Y shows that not only the guest staying beyond the 25th floor faced an enhanced risk, but this risk was manifold enhanced during the night time as compared to the day time. This is because during the night time most of the rooms are occupied and the guests being asleep could not show a prompt and appropriate response in the event of any major conflagration. This risk was enhanced to the extent of being lethal for the guest staying on or above the 50th floor during the night. High Risk Low 10 20 30 40 50 55 60 Floors (Z) As per the graph Z, the unrealistically high number of floors in this building posed a major threat to the fire fighters operating on the upper floors. Infact, this risk analysis revealed that the fire fighters operating on the top most floors faced a major risk to their lives. This risk was manifold multiplied in case of a fire on the intermediate floors. 4.2 Travel Distance The nearest fire station to this building is located at a distance of 30 KM. thus it is quite obvious that the fire and rescue services would not be able to execute a timely response in case a fire breaks in this high rise building. 4.3 Telephone and Electrical Shafts The telephone and electrical shafts in this building not only run through its three stairways but are not properly sealed with the fire proof valves. The telephone and electrical wires running through these shafts have many joints and are not made of fire proof insulation. Thus they can not only start a major fire owing to any short circuit but the unsealed shafts could also accelerate the vertical and horizontal spread of smoke and flames (Gurnell, 2007). 4.4 Stairways One of the stairways opening to the left of this building was found to be blocked by the construction and repair accessories. Also all the stairways had telephone and electrical shafts running over them that should ideally be placed in the elevator shafts. This could turn these stairways into virtual traps in the event of a fire and could inhibit the escape and movement of both the guests and the fire fighters. 4.5 Storage The analysts discovered that vast amounts of alcohol, animal and vegetable fats, and edible oils were stored in the kitchen area that lied on an intermediate floor. Also the storage rooms located on the respective floors stored highly inflammable materials like bleaches, old newspapers and magazines, room fresheners and insecticides. These inflammable substances could prove to be a potent source of fuel to aggravate a fire. 4.6 Falling Debris The aluminium panels fixed on the façade of this building and the glass installed in the window panes was not found to be of fire resistant quality. These materials could turn into falling debris and shrapnel in case of a fire and could jeopardize the safety of both the guests and fire fighters (NFPA, 1990). 4.7 Traffic This high rise building being placed in a highly constricted street that accommodates dense traffic all the time could hamper the fire fighting operations (NFPA, 2008). The response of the fire fighters could also get threateningly delayed because of dense traffic. 4.8 Staff A random interview conducted on a number of staff members revealed that most of the staff of this hotel was not aware of proper steps to be taken in case a fire breaks out. Also they were not subjected to any kind of fire drills during their tenure in this hotel (Koo, 2003). Obviously this would leave the guest in this hotel to the mercy of personal initiative or fate in case a fire breaks out. 5.0 Conclusion These findings definitely led to the conclusion that there hardly existed a fire safety policy in this high rise building and the revealed risk factors could threaten the safety of the staff, guests and fire and rescue personnel any time. Thus an Integrated Risk Management Plan definitely needs to be drafted on a priority basis. 6.0 Recommendations All the floors should be provided with fire escapes. Fire extinguishers should be installed on all the floors and these must be serviced on a regular basis. All the unsealed telephone and electrical shafts should be plugged with a fire proof material. The electrical wirings should be changed or the joints in them should be taped with a fire proof insulator. A well equipped fire station should be established in the vicinity of this neighbourhood. Telephone and electrical shafts should be shifted from the stairways to the elevator shafts. The obstacles in the stairways should be removed. The outside aluminium and glass panels should be replaced by fire proof materials. The staff should be regularly subjected to mock fire drills (United States Fire Administration, 1991). The inflammable substances stored in the kitchen and the respective floors should be shifted to a safe storage area. Works Cited Chicago high rise fire injuries 37. 7 December 2004. CNN.com . 16 June 2008 Evacuating High Rise Building. 26 January 2003. OSHO FACT SHEET. 16 June 2008 Gurnell.P. 2007. High Rise Fire Risk. The Daily Telegraph. 16 June 2008 High Rise Building Fire. 23 February 1990. NFPA. 16 June 2008 Koo.L.T. 2003. Old High Rise Buildings. Questia. 16 June 2008 United States Fire Administration. National Fire Data Centre. High rise Office Building Fire, 1991 Read More
Tags
Cite this document
  • APA
  • MLA
  • CHICAGO
(Risk Analysis of High Rise Buildings in Abu Dhabi Case Study, n.d.)
Risk Analysis of High Rise Buildings in Abu Dhabi Case Study. https://studentshare.org/management/2031862-high-risk-building
(Risk Analysis of High Rise Buildings in Abu Dhabi Case Study)
Risk Analysis of High Rise Buildings in Abu Dhabi Case Study. https://studentshare.org/management/2031862-high-risk-building.
“Risk Analysis of High Rise Buildings in Abu Dhabi Case Study”. https://studentshare.org/management/2031862-high-risk-building.
  • Cited: 0 times

CHECK THESE SAMPLES OF Risk Analysis of High Rise Buildings in Abu Dhabi

Fire Risk Factors in the High Rise Buildings in Abu Dhabi

… The paper 'Fire Risk Factors in the high rise buildings in abu dhabi' is a good example of a Management Case Study.... The paper 'Fire Risk Factors in the high rise buildings in abu dhabi' is a good example of a Management Case Study.... Introduction Risk assessment has become an important constituent of the overall strategies adopted by fire and rescue services in abu dhabi.... Massive high rise buildings are in vogue that house the offices of top-notch business and financial institutions and organizations that are increasingly shifting their operations to this oil-rich kingdom....
6 Pages (1500 words) Case Study

Service Management Fair and Rescue

Risk Assessments: Identify risk factors in hotels or any building above 54 floors in abu dhabi.... The city such as abu dhabi in the United Arab Emirates is known for its high quality and booming industrial nature.... The city such as abu dhabi in the United Arab Emirates is known for its high quality and booming industrial nature.... The high rise hotels especially keep in mind the standards of their guest and the measurements are made accordingly....
8 Pages (2000 words) Case Study

Analysis of Risk Factors in High Rise Buildings in Abu Dhabi City

… The paper 'Analysis of Risk Factors in high rise buildings in abu dhabi City" is a good example of a management case study.... The paper 'Analysis of Risk Factors in high rise buildings in abu dhabi City" is a good example of a management case study.... high rise buildings are one such insignia of development that have almost taken over the burgeoning city of Abu Dhabi in a matter of a few years.... Such a craze for high rise buildings has been unleashed without giving any due consideration to the planning and institutional organization that is required to neutralize the risk factors associated with urbanization and modernization (CNN, 2004)....
7 Pages (1750 words) Case Study

Risk Factors in a High Rise Building at Abu Dhabi

This will not only ensure a timely neutralization of these risk factors but will redefine the design and organization of the high rise buildings to be built in abu dhabi in the future.... The irony is that the loses incurred due to fires in high rise buildings often prove to be much costlier than the investments required to identify and replace the factors and reasons that cause such fires in the first place.... The objective of this report is to unravel the factors that are inherent in the design and fabrication of most of the high rise buildings at Abu Dhabi....
6 Pages (1500 words) Case Study

Le Meridien hotel in Abu Dhabi - Risk Management

… The paper 'Le Meridien hotel in abu dhabi - Risk Management " is a good example of a management case study.... Le Meridien hotel in abu dhabi has got fifty-four floors.... The paper 'Le Meridien hotel in abu dhabi - Risk Management " is a good example of a management case study.... Le Meridien hotel in abu dhabi has got fifty-four floors.... Smoke and heat detection alarms Le Meridien hotel in abu dhabi has got fire and heat detectors....
8 Pages (2000 words) Case Study

Analysis of Law Ethics and Globalization with Respect to Fire Safety

Dina (2008) indicates that between the year 2002-2007, Abu Dhabi suffered 14,000 fire incidents over the same period, central Scotland suffered 279 fire cases that resulted in 16 deaths in central Scotland and 4624 deaths in abu dhabi.... This essay analyses fire safety in the United Kingdom and abu dhabi emirate by looking into ways in which fire safety order 2005 operates and how it could be applied internationally to effect sustainable fire safety measures....
11 Pages (2750 words) Assignment

Globalization of Fire Safety Legislation and Its Effects on the Fire Safety Practitioners

The essay concludes by comparing case studies in Lancashire (United Kingdom) with abu dhabi emirate (United Arab Emirates) as a function of data presented in table 1.... The abu dhabi emirate abu dhabi emirate had a population of 1.... From 2002 to 2007, abu dhabi experienced 14000 fire incidents that had very high economic costs in terms of destruction of property and loss of lives (Dani 2008).... abu dhabi has five fire stations that respond to emergency incidents....
10 Pages (2500 words) Coursework

Fire Service and Safety

… The paper "Fire Service and Safety" is a great example of coursework on social sciences.... Community safety is the expression that is used to cover prevention and protection.... All the services are delivered by competent staffs of various organizations that are based in geographical areas....
12 Pages (3000 words) Coursework
sponsored ads
We use cookies to create the best experience for you. Keep on browsing if you are OK with that, or find out how to manage cookies.
Contact Us